Bayou St. John

3130 De Soto Street is in Bayou St. John, zoned HU-RD2 (Older neighborhoods, two-family homes mixed with single-family homes). It is in the Esplanade Ridge historic district under partial HDLC control, where demolition needs HDLC review. The city has 3 permits on record here; the most recent, a renovation (structural) permit, was filed in July 2019. 2 are still open. On this block in the past year: 10 requests to 311 and 4 calls to police.

Zoning
HU-RD2
Historic district
Esplanade Ridge (Partial control)
National Register
Esplanade Ridge Historic District
Council district
A
Ward
6
Lot size
4,500 sq ft
Parcel
41020622

Everything on record here

3 records, newest first · 2 open

  1. Permit Renovation (Structural) Permit Issued

    Level and shim limited by the fireplaces. Change the wood framing around the fireplaces. Tuckpoint all piers and fireplaces.

    Permit
    19-19471-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $31,000
    Fees
    $323
    Contractor
    Abry Brothers, Inc.
    Days from application to issue
    0
    Expires
    Jan 8, 2020
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  2. Permit HDLC COA Permit Issued

    Level and shim limited by the fireplaces. Change the wood framing around the fireplaces. Tuckpoint all piers and fireplaces.

    Permit
    19-19471-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Dec 20, 2019

    See this permit on One Stop

  3. Permit Electrical Service / Circuit / Feeder Permit Finaled

    Demo out the existing meter/panel/stem. Install a new 200 amp meter can with a 2" stem straight up with 2/0 copper feeder wires. Re-crimp the "hot" service drop to restore power to the service. Upgrade main ground system to code with a #4 ground wire from the meter can to an intersystem ground bar to 2 - 8' ground rods to water line and ensure gas and cold water lines are bonded. Install a 200 amp main breaker 42 circuit panel and correctly sized circuit breakers for existing "hot" branch wiring. Mark panel and breakers. I

    Permit
    19-18301-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $2,350
    Fees
    $100
    Contractor
    William Floyd Schell III
    Days from application to issue
    1
    Expires
    Dec 7, 2019
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop