French Quarter

200 Royal Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 15 permits on record here; the most recent, a VCC general work permit, was filed in July 2025. 12 are still open. On this block in the past year: 2 requests to 311 and 196 calls to police.

Zoning
VCC-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
4
Lot size
31,881 sq ft
Parcel
41021695

Everything on record here

15 records, newest first · 12 open

  1. Permit VCC General Work Application Accepted

    VCC review only. Please reference permit application #25-08786-RNVS and submitted application with confirmation #3JR1HG for the proposed relocation of the Hotel Monteleone cooling tower from the property address of 624 Bienville Street (Site address per the Nola Property Viewer: 200 Royal Street) to the roof of 227 Chartres Street, which requires the routing of new chilled water lines. All affected properties—except for the crossing over Exchange Place—are owned by the Hotel. As part of the chilled water routing, two new lines will pass through the existing brick wall at the rear of 614 Bienville Street, where the building abuts Exchange Place. From there, the lines will continue beneath the one-story pedestrian bridge, running just below the second floor level. The pipes will be fully concealed beneath the bridge and will not be supported by it. Upon reaching 200 Royal Street, the lines will penetrate the masonry wall, turn toward Bienville street at the same elevation close to the ceiling and into the hotel's Engine Room. Finally the pipes will turn downward inside this room and connect to the chillers. The existing cooling tower piping, exposed on the Exchange Place side of 624 Bienville St, can be removed and facade restored.

    Permit
    25-19877-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Application Accepted

    VCC review only. Please reference permit application #25-08786-RNVS and submitted application with confirmation #3JR1HG for the proposed relocation of the Hotel Monteleone cooling tower from the property address of 624 Bienville Street (Site address per the Nola Property Viewer: 200 Royal Street) to the roof of 227 Chartres Street, which requires the routing of new chilled water lines. All affected properties—except for the crossing over Exchange Place—are owned by the Hotel. As part of the chilled water routing, two new lines will pass through the existing brick wall at the rear of 614 Bienville Street, where the building abuts Exchange Place. From there, the lines will continue beneath the one-story pedestrian bridge, running just below the second floor level. The pipes will be fully concealed beneath the bridge and will not be supported by it. Upon reaching 200 Royal Street, the lines will penetrate the masonry wall, turn toward Bienville street at the same elevation close to the ceiling and into the hotel's Engine Room. Finally the pipes will turn downward inside this room and connect to the chillers. The existing cooling tower piping, exposed on the Exchange Place side of 624 Bienville St, can be removed and facade restored.

    Permit
    25-19877-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $10,000
    Fees
    $170
    1. Application submitted

    See this permit on One Stop

  3. Permit VCC Security Camera Application Permit Issued

    Per 03/26/2024 Commission approval and materials stamped VCC approved 04/01/2024: Retroactive approval of two (2) security cameras associated with Project NOLA crime prevention initiative on the Royal/Iberville and Exchange Place/Iberville corners of the building, approximately 10'-0" above sidewalk. Paint mounting arm to match color of adjacent building surface to minimize visibility.

    Permit
    24-07147-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $3,000
    Fees
    $0
    Days from application to issue
    18
    Expires
    Oct 1, 2024

    See this permit on One Stop

  4. Permit Dumpster/Construction Zone Application Accepted

    Preparing to make balcony and facade repairs in Exchange Place (200block) behind the Hotel Monteleone. Owner would like to close Exchange Place for construction for 12 months.

    Permit
    24-06652-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40

    See this permit on One Stop

  5. Permit VCC General Work Permit Issued

    ***ALL WORK TO MATCH EXISITNG Repairs to fire escape that was damaged by delivery truck. Match existing details.

    Permit
    23-35303-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    7
    Expires
    Jul 9, 2024

    See this permit on One Stop

  6. Permit Renovation (Structural) In Review

    Repairs to fire escape that was damaged by delivery truck. Match existing details.

    Permit
    23-35303-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $20,902
    Fees
    $338
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  7. Permit Street Cut Other

    in no go zone, sent to DPW for review

    Permit
    20-37826-RSTC
    Type
    Street Cut
    Work
    Street Cut
    Estimated cost (applicant’s figure)
    $0
    Fees
    $310
    Days from application to issue
    75
    Expires
    Apr 27, 2021

    See this permit on One Stop

  8. Permit Street Cut Other

    UPGRADE SYSTEM

    Permit
    19-26857-RSTC
    Type
    Street Cut
    Work
    Street Cut
    Estimated cost (applicant’s figure)
    $0
    Fees
    $1,120
    Days from application to issue
    256
    Expires
    Nov 5, 2020

    See this permit on One Stop

  9. Permit VCC General Work In Review

    For VCC preliminary review This project consists of renovations to the Hotel Monteleone’s “Iberville Tower”. The Iberville tower is a 17-story brick and limestone addition to the main hotel that occupies the corner of Royal and Iberville Streets. The renovation will occur on floors 2 through 15. The renovation will consist of new finishes, mechanical, electrical, plumbing, sprinkler, and some work related to windows. The 2nd floor is the ballroom, and new steel windows are proposed at the Iberville Façade. The window locations correspond with existing niches in the limestone wall. The niches are currently filled in with a ceramic tile. The new windows will match the style and profiles of the new steel doors added recently at the 1st floor of this building. On floors 3-10, the existing aluminum double-hung windows are to be refurbished, and new steel storm windows are to be installed on the interior side of the opening, to help with thermal and sound concerns. On floors 11-15, the existing aluminum sliding windows are to be replaced, in kind. The windows are not original to the building, and were added in a later addition. They are poor quality, and in disrepair. They are to be replaced with new hurricane impact rated aluminum windows, in the same size and configuration. There are small double hung windows in the stairwell that faces exchange alley. These windows are steel, and badly rusted. These windows are to be replaced with new aluminum windows of the sa

    Permit
    16-32135-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  10. Permit Renovation (Non-Structural) Other

    Interior and exterior renovation to floors 2 – 15 of existing hotel as per plans.

    Permit
    16-32135-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $2,000,000
    Fees
    $18,090
    Contractor
    F H Myers Construction Corporation, F H Meyers Construction Corp

    See this permit on One Stop

  11. Permit Special Event Permit Issuance Active

    CERTIFICATE OF OCCUPANCY FOR SPECIAL EVENT,"TALES OF THE COCKTAIL", AS PER REVENUE CASE #: 1984 AND DPW #: 2011-06. TIME FOR THE EVENT/07-20-2011-9AM TO 5PM/07-22ND-2011 THRU 07-23RD- 9AM TO 5AM-2011.

    Permit
    11SPE-00271
    Type
    Special Event
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
  12. Permit Film Master Application Acceptance - Approved No Review

    Certificate of Occupancy to place a stage on Royal Street for the Monteleone Hotel Street Event,"THE DAILY BEAST",on October 22nd,2010 from 6:P.M. - 8:P.M. as per Sketch and Public Works Approval.

    Permit
    10SPE-00223
    Type
    Film Master
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
    Days from application to issue
    5
  13. Permit Residential

    test

    Permit
    10TMP-000116
    Type
    Residential
    Work
    Homeowner Repair
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
  14. Permit Film Master Application Acceptance - Approved No Review

    Special Event: Food and Wine Festival: Stage for Anniversary of Carosel Bar. 5pm to 8 pm Thursday, May 21, 2009

    Permit
    09SPE-00132
    Type
    Film Master
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    5
  15. Permit Mechanical Annual Renewal Active

    ANNUAL INSURANCE INSPECTION

    Permit
    06MCH-01145
    Type
    Mechanical
    Work
    Stationary Equipment Annual
    Estimated cost (applicant’s figure)
    $0
    Fees
    $20