French Quarter

1002 Bienville Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 7 permits on record here; the most recent, a VCC general work permit, was filed in October 2025. 4 are still open. On this block in the past year: 1 request to 311 and 44 calls to police.

Zoning
VCC-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
4
Lot size
2,099 sq ft
Parcel
41021769

Everything on record here

7 records, newest first · 4 open

  1. Permit VCC General Work Permit Issued

    re-point side wall (Rampart side) using VCC mortar mix recipe. To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Lath or adherents of any kind are prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    25-30957-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Apr 8, 2026

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Permit Cancelled

    re-point side wall (Rampart side) using VCC mortar mix recipe. To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Lath or adherents of any kind are prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    25-30957-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $50,000
    Fees
    $555
    1. Application submitted

    See this permit on One Stop

  3. Permit Electrical Repair / Replacement / Addition Permit Issued

    changed subpanel and 10 new circuits

    Permit
    15-00741-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $70
    Contractor
    Miguel Rivera
    Days from application to issue
    0
    Expires
    Jul 9, 2015

    See this permit on One Stop

  4. Permit VCC General Work Permit Finaled

    To replace the 3-tab asphalt shingle roofing with natural slate to repair the shutters on the Bienville elevation where possible, and to replace to match existing where missing irreparable to replace balcony decking on Bienville elevation

    Permit
    14-04786-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    5
    Expires
    Aug 12, 2014

    See this permit on One Stop

  5. Permit General Mechanical Permit Finaled

    ELEC. HVAC/D GEORGE 468-6595 CK#43514654

    Permit
    13-36285-MECH
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $65
    Contractor
    Darryl J Degeorge Jr
    Days from application to issue
    0
    Expires
    Feb 28, 2014

    See this permit on One Stop

    Placed here by its tax bill number from “2421 Bienville St”.

  6. Permit Electrical Service / Circuit / Feeder Inspection - Completed
    Permit
    04ELC-01496
    Type
    Electrical Service / Circuit / Feeder
    Work
    Service-Circuits-Feeders
    Estimated cost (applicant’s figure)
    $0
    Fees
    $72
    Contractor
    Harris & Bridges Servcie
    Days from application to issue
    10
  7. Permit Electrical

    ELECTRICAL VACANCY REPAIRS MULTI-FAMILY DWELLING FRANK PASCAL

    Permit
    E01003699
    Type
    Electrical
    Days from application to issue
    0