239 Decatur Street is in French Quarter, zoned VCE-1 (French Quarter district under Vieux Carré Commission review). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 24 permits on record here; the most recent, a plumbing permit, was filed in July 2026. 17 are still open. There were 3 past code enforcement cases, the latest in November 2025, all closed. On this block in the past year: 49 requests to 311 and 137 calls to police.

Zoning
VCE-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
4
Lot size
1,382 sq ft
Parcel
41021886

Everything on record here

27 records, newest first · 17 open

  1. Permit Plumbing Permit Application Accepted

    Water meter out over 6 months.

    Permit
    26-22369-PLMB
    Type
    Plumbing Permit
    Work
    Plumbing Permit
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
    Contractor
    Sidney Lapuyade, IV
    1. SWB Filing Fee Unpaid
    2. Plumbing Underground
    3. Plumbing Rough In/ Top Out
    4. Plumbing Tie In
    5. Plumbing Final
    6. Application Submitted Complete
    7. SWBNO Plumbing Intake Revisions Needed
    8. SWBNO Plumbing Approval Pending

    See this permit on One Stop

  2. Code enforcement Case 25-12876-MPM Closed

    The case was filed on 11/19/2025 but has since been closed without further action.

    The city links this case to permit 26-22369-PLMB.

  3. Code enforcement Case 25-12870-MPM Closed

    The case was filed on 11/19/2025 but has since been closed without further action.

    The city links this case to permit 26-22369-PLMB.

  4. Permit VCC General Work Permit Issued

    Remove existing roofing material Repair and/or replace underlayment as necessary Install new 18” x 12” natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing where necessary Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.

    Permit
    24-33899-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    May 8, 2025

    See this permit on One Stop

  5. Permit Renovation (Non-Structural) Permit Cancelled

    Remove existing Fire-Free Synthetic Slate Roof and Install new, S1-Grade Natural Slate Roof, either CUPA Black or Vermont Gray-Green, depending upon availabilty.

    Permit
    24-33899-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $44,250
    Fees
    $518
    Contractor
    All Ways Roofing LLC
    1. Application submitted
    2. Zoning review
    3. Application review
    4. Plan review
    5. Permit approved

    See this permit on One Stop

  6. Permit VCC General Work Permit Issued

    Per VCC review and approval of mortar sample and brick sample 11/08/24 To repoint masonry, FRONT ELEVATION ONLY, utilizing mortar mixed and applied per the VCC standard detail sheet (attached) THE VCC DOEST NOT ALLOW PREMIXED BAGS Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. remove vegetation sand and paint windows to match unclog scuppers and paint to match

    Permit
    24-28285-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    49
    Expires
    May 8, 2025

    See this permit on One Stop

  7. Permit Renovation (Non-Structural) Permit Cancelled

    Tuck point and paint front wall only remove vegetation sand and paint windows to match unclog scuppers and paint to match

    Permit
    24-28285-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $38,500
    Fees
    $473
    Contractor
    Kendall Ward
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  8. Permit VCC Security Camera Application Application Accepted

    one exterior cameras have been previously installed and constructed on and they are located on both sides of the upper front of the building.

    Permit
    24-27869-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  9. Permit VCC General Work Permit Issued

    We will replaced one 10 ton air handler and one 10 condenser unit , reusing existing ductwork.

    Permit
    24-23803-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Feb 5, 2025

    See this permit on One Stop

  10. Permit Mechanical HVAC In Review

    We will replaced one 10 ton air handler and one 10 condenser unit , reusing existing ductwork.

    Permit
    24-23803-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $33,125
    Fees
    $86
    Contractor
    AJ Barcia's Heating & A\C
    1. Application submitted
    2. Application review

    See this permit on One Stop

  11. Permit VCC Sign In Review

    A sign demsoins will be 24x36x2

    Permit
    24-20576-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  12. Permit Attached Sign Application Accepted

    A sign demsoins will be 24x36x2

    Permit
    24-20576-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $325
    1. Application submitted

    See this permit on One Stop

  13. Permit VCC General Work Other

    Remove vegetation growing from the building Repair broken glass with real glass. Plexiglass is NOT allowed Remove existing, impermissible, and/or broken door hardware on the Iberville side door. Install new door hardware to match the center door Remove all existing, unpermitted and/or unshielded light fixtures Install three (3) white Remcraft 100 Series, cylinder light fixtures. One each in the existing conduits at the transom windows Fixtures shall be painted or prefinished to match adjacent building surface. Repair, replace damaged galvanized metal, round downspouts, scuppers, brackets to match existing. Paint to match the bricks and adjacent surface. To prepare for painting by washing using a low water pressure (400 psi max) and/or sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: First floor walls, doors, windows, downspouts, scuppers...Westhighland White SW 7566, flat or satin finish Second & third floor windows...Pure White SW 7005, semigloss *In response to violation*

    Permit
    19-33218-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Apr 21, 2020

    See this permit on One Stop

  14. Permit Renovation (Non-Structural) Other

    Exterior Painting, Removal of Vegetation, Repair/Painting Gutter, Replacing Door Hardware, Replacing Light Fixture

    Permit
    19-33218-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,000
    Fees
    $98
    1. Application submitted

    See this permit on One Stop

  15. Permit VCC Sign In Review

    new sign

    Permit
    18-14854-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  16. Permit VCC General Work In Review

    Exterior paint and lights

    Permit
    18-14852-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  17. Permit Attached Sign Permit Cancelled

    Install 60 sq ft hanging sign as per sketch

    Permit
    18-14854-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $293
    1. Application submitted

    See this permit on One Stop

  18. Permit Renovation (Non-Structural) Other

    Exterior paint and lights

    Permit
    18-14852-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $550
    Fees
    $98
    1. Application submitted
    2. Application review

    See this permit on One Stop

  19. Permit Electrical Repair / Replacement / Addition Permit Issued

    Replacing 19 existing light fixtures with 19 new light fixtures in new locations located inside the building. No service increased or decreased, no circuits added.

    Permit
    18-04363-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $750
    Fees
    $40
    Contractor
    Giuseppe Filippo Adkins
    Days from application to issue
    8
    Expires
    Aug 14, 2018
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  20. Permit Renovation (Non-Structural) Permit Issued

    Non-structural repairs to existing restaurant. Repairs include electrical fixtures, plumbing fixtures, and bar repair. No HVAC. No demolition of any wall. No exterior work allowed under this permit.

    Permit
    18-02891-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $6,000
    Fees
    $420
    Days from application to issue
    0
    Expires
    Jul 25, 2018
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Permit approved
    5. Issue date
    6. First inspection

    See this permit on One Stop

  21. Code enforcement Case ENVHADJ-20053838SN Closed

    The property was inspected on 06/27/2005 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 26-22369-PLMB.

  22. Permit Mechanical Annual Fee Pending
    Permit
    03MCH-07078
    Type
    Mechanical
    Work
    Stationary Equipment Annual
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
  23. Permit Sign

    PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2004 PAID FOR 1

    Permit
    S04000115
    Type
    Sign
    Days from application to issue
    0
  24. Permit Sign

    PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2003

    Permit
    S03000193
    Type
    Sign
    Days from application to issue
    0
  25. Permit Sign

    PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE

    Permit
    S02000380
    Type
    Sign
    Days from application to issue
    0
  26. Permit Sign

    PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2001 PAID

    Permit
    S01000419
    Type
    Sign
    Days from application to issue
    0
  27. Permit Sign

    PROJECTING SIGN RESTAURANT 49 AND UNDER ERECT A NEW DBL FACED WOOD PROJ SIGN READING "SAMURAI SUSHI-SUSHI".DIMENSIONS OF SIGN TO BE 20 X 30 AS PER VCC#990257.

    Permit
    S99000861
    Type
    Sign