French Quarter

932 Esplanade Avenue is in French Quarter, zoned VCR-2 (French Quarter residential, with somewhat higher density than VCR-1). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 9 permits on record here; the most recent, a VCC general work permit, was filed in June 2026. 8 are still open. On this block in the past year: 12 requests to 311 and 48 calls to police.

Zoning
VCR-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
6
Lot size
4,343 sq ft
Parcel
41021909

Everything on record here

9 records, newest first · 8 open

  1. Permit VCC General Work Permit Issued

    MAIN BUILDING ONLY to restucco the front left elevation of the main house using VCC approved stucco with scoring per applicaiton and materials recieved 6/23/26 and stamped VCC approved 6/24/26. Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. LATH OF ANY KIND IS NOT ALLOWED.

    Permit
    26-18306-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    6
    Expires
    Dec 24, 2026

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Application Accepted

    REPAIR / REPLACEMENT OF EXISTING STUCCO ON COURTYARD SIDES OF EXISTING BUILDING IN VCC DISTRICT. NO CHANGE OF AREA, NO CHANGE OF USE, NO CHANGE OF OCCUPANCY.NO CHANGE OF ADDRESS. NO CHANGE OF ENCROACHMENT. NO WORK AT EXISTING CARRIAGE HOUSE. **VCC Permit Issued 6/24

    Permit
    26-18306-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,500
    Fees
    $220
    1. Application submitted
    2. Application review

    See this permit on One Stop

  3. Permit VCC Paint Application Accepted

    Minor Stucco repairs

    Permit
    26-16458-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  4. Permit VCC General Work Permit Issued

    Work approved: Remove existing roofing material Repair and/or replace underlayment as necessary Install new 12” x 18” natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.

    Permit
    22-31145-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Apr 18, 2023

    See this permit on One Stop

  5. Permit Renovation (Non-Structural) In Review

    Changing Slate Roof

    Permit
    22-31145-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $59,000
    Fees
    $623
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  6. Permit VCC General Work Permit Issued

    Tuck point masonry were needed on both the front and rear building using VCC approved motor mix (see attached). Replace and repair damaged railing on rear of building and dependancy to match existing. Replace front 2nd floor balcony soffit with beadboard to match exisisting small beadboard. Beadboard sheets are not approvable. Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). Repair bottom of front balcony columns. Secure loose roof slate at chimney of rear building. Secure lower panel on front entry door and reseal with low gloss clear finish (to match existing). All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    17-30406-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    12
    Expires
    Mar 25, 2018

    See this permit on One Stop

  7. Permit Renovation (Non-Structural) Other

    Repair termite damage wood rafters in rear attic. Tuck point masonry walls in front and rear attic. Tuck point left side of rear separate building at the back of the property. Replace and repair damaged railings in rear yard. Replace front 2nd floor balcony soffit with identical material, replace front balcony wood sleeper/support and 20 pine t&g porch boards. Repair bottom of front balcony steel columns. Secure loose roof slate at chimney of rear building. Secure lower panel on front entry door and reseal with low gloss clear finish.

    Permit
    17-30406-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $14,545
    Fees
    $293
    Contractor
    Da Vinci Builders LLC
    Days from application to issue
    20
    Expires
    Mar 26, 2018

    See this permit on One Stop

  8. Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved

    VACANCY

    Permit
    09ELC-17361
    Type
    Electrical Repair / Replacement / Addition
    Work
    Repair-Replacement-Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    Stuart Electric Inc
    Days from application to issue
    10
  9. Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved

    HURRICANE REPAIRS

    Permit
    08ELC-20072
    Type
    Electrical Repair / Replacement / Addition
    Work
    Repair-Replacement-Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    Bellande & Sons Elec
    Days from application to issue
    10