French Quarter
738 Dumaine Street is in French Quarter, zoned VCR-2 (French Quarter residential, with somewhat higher density than VCR-1). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 21 permits on record here; the most recent, a street cut permit, was filed in May 2026. 4 are still open. On this block in the past year: 14 requests to 311 and 54 calls to police.
- Zoning
- VCR-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 2,142 sq ft
- Parcel
- 41022058
Everything on record here
22 records, newest first · 4 open
-
Permit Street Cut Permit Issued
4x4 sidewalk cut. Associated with small cell installation. Replace existing poles with a new pole
- Permit
- 26-14521-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $112
- Contractor
- Timothy Jason Carman
- Days from application to issue
- 37
- Expires
- Dec 19, 2026
-
Permit VCC General Work Other
To replace damaged fascia on the Bourbon St. side of the main building and to re-slope the gutter to achieve proper drainage as per materials stamped VCC approved 10/27/2025.
- Permit
- 25-31578-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Perdomo Roofing and Sheet Metal, LLC
- Days from application to issue
- 14
- Expires
- Apr 27, 2026
-
Permit Renovation (Non-Structural) Permit Issued
Exterior fascia and gutter repairs on Burgundy Street side of property
- Permit
- 25-31578-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,382
- Fees
- $210
- Contractor
- Perdomo Roofing and Sheet Metal, LLC
- Days from application to issue
- 19
- Expires
- Apr 28, 2026
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Other
To replace existing metal roofing on rear building with new standing seam galvanized metal roofing, per materials stamped VCC approved 04/23/2024. Work includes: • Removal of existing metal roofing • Repair/replacement of underlying plywood decking as necessary • Installation of new standing seam galvanized metal roofing Note: All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 24-09573-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 20
- Expires
- Oct 23, 2024
-
Permit Renovation (Non-Structural) In Review
Metal Roof Replacement - Seperate Structure
- Permit
- 24-09573-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $9,028
- Fees
- $255
- Contractor
- Perdomo Roofing and Sheet Metal, LLC
- Application submitted
- Application review
- Zoning review
-
Permit Electrical Repair / Replacement / Addition Permit Cancelled
Service/repair cell tower
- Permit
- 21-06474-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $49
- Contractor
- Aaron J Labourdette
- Application submitted
- Application review
- Permit approved
-
Permit Change of Address Permit Issued
addressing at Entergy needed correction 740 Dumaine St KEEP Change 740 1/2 Dumaine St to 834 Bourbon St Change 738 Dumaine Apt LO to 738 Dumaine St
- Permit
- 20-00944-ECOA
- Type
- Change of Address
- Work
- Change of Address
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 50
- Expires
- Sep 4, 2020
- Application submitted
- Permit approved
- Issue date
Placed here by an address range from “740 Dumaine St, 834 Bourbon St, 738 Dumaine St”.
-
Permit Sidewalk Repair Other
Decommissioning/ removing existing small cell pole and removing foundation 2' below grade and perform sidewalk restoration
- Permit
- 19-36928-RSWR
- Type
- Sidewalk Repair
- Work
- Sidewalk Repair
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Crescent Construction
- Days from application to issue
- 0
- Expires
- May 19, 2020
-
Permit Electrical Repair / Replacement / Addition Permit Issued
Disconnect power - modify pole - reconnect power. Credit Card Payment.
- Permit
- 19-08856-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Aaron J Labourdette
- Days from application to issue
- 0
- Expires
- Sep 21, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Short-term rental Short Term Rental license application Denied
- Type
- Short Term Rental
- Operator
- David Garrison
-
Permit Street Cut Other
EntergyWR#698854 install gas main along bourbon st st louis to dumaine,
- Permit
- 18-15146-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Other
To install approximately 600 sq. ft. of 18”x18” blue-green flagstone on top of existing concrete slab in courtyard Flagstone to be laid in a bed of mortar on top of concrete, adding approximately 3” of height to the courtyard Existing drains and grading for drainage to be retained or replicated
- Permit
- 17-06246-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 9
- Expires
- Sep 2, 2017
-
Permit Renovation (Non-Structural) Permit Cancelled
Laying flagstone over a concrete slab in my patio and driveway.
- Permit
- 17-06246-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $7,500
- Fees
- $150
- Contractor
- Cydle Ducote
-
Permit VCC General Work Permit Cancelled
Roof repairs on rear dependency, per materials stamped VCC approved 11/16/16, as follows: Cut reglet and install new 24 gauge galvanized metal counterflashing at Bourbon-side dependency parapet. Seal reglet with NP-1 cauk. Install new 24 gauge galvanized apron flashing at Madison-side edge of dependency roof. Rivet and caulk all seams with NP-1 caulk. Clean and coat existing galvanized standing-seam roof with non-fibered aluminum coating (finished appearance must be matte, not gloss). Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 16-35513-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Galland Roofing
- Days from application to issue
- 15
- Expires
- May 16, 2017
-
Permit VCC General Work Other
Millwork repairs and paint, per attached materials stamped VCC approved 11/17/16, as follows: Remove deteriorated dependency balcony decking, handrail and posts, and replace to match existing in profile, size and material. Remove/replace deteriorated soffit under dependency balcony, to match existing. Remove/replace deteriorated weatherboards as needed on main building and dependency, to match existing, Repair french doors where cut, extending bottom rail to threshold. Repair wooden courtyard gate as needed All repair/replacement work shall match existing in color, size, material, detail, profile and exposure To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: Walls: grey, flat or satin finish Wooden elements including windows, french doors, trim, fascia/soffit/outriggers of balcony, balcony railing and posts: cream, semigloss Top of balcony decking: dark grey, semigloss Main building front doors: brick red, semigloss Shutters: grey-blue, semigloss Ironwork: brick red, gloss Failure to exactly match permit specified colors will result in a VCC violation and mandated repainting. This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastome
- Permit
- 16-35517-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 16
- Expires
- May 17, 2017
-
Permit VCC General Work Permit Cancelled
Exterior painting of both buildings, the main cottage at 738-40 Dumaine and the Servant's Quarter at 834 Bourbon/rear. Sanded wooden siding, scraped, masonary surfaces to be be bleached washed and allowed to dry before paining. Existing paint to match as per VCC Approval.
- Permit
- 16-35520-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Exterior painting of both buildings, the main cottage at 738-40 Dumaine and the Servant's Quarter at 834 Bourbon/rear. Sanded wooden siding, scraped, masonary surfaces to be be bleached washed and allowed to dry before paining. Existing paint to match as per VCC Approval.
- Permit
- 16-35520-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $15,010
- Fees
- $210
- Contractor
- Clyde Ducote
-
Permit Renovation (Structural) Other
Repair balcony, remove/replace posts, hand rails and decking. Insulate doors, windows, repair main gate; prep both buildings for painting as per part of contract description and VCC Approval.
- Permit
- 16-35517-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $9,690
- Fees
- $255
- Contractor
- Clyde Ducote
- Days from application to issue
- 3269
- Expires
- Apr 7, 2026
-
Permit Renovation (Non-Structural) Other
Repair leaking roof at the rear servant quarters: fabricate and install 24 gauge flashing and cot with aluminum coating as per contract description and VCC Approval.
- Permit
- 16-35513-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,302
- Fees
- $113
- Days from application to issue
- 23
- Expires
- May 17, 2017
-
Permit Renovation (Structural) Permit Issued
Add wall ties to stabilize walls as per sketch and VCC Approval.
- Permit
- 16-25668-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $128
- Contractor
- 4 H Construction Company Inc
- Days from application to issue
- 54
- Expires
- Mar 28, 2017
-
Permit VCC General Work Other
Install new structural ties, per drawings approved by Architectural Committee 08/09/16 and stamped VCC approved 09/28/16, as follows: Install three (3) new 8” round galvanized steel plates, with 5/8” threaded rods at approximately 11’-0” above grade. Two (2) of the ties will be installed on the riverside of the Bourbon elevation, extending into the existing 2x8 floor joists. The lakeside tie will extend further into the structure, tie into the existing double joist header, and be secured with a 4” x 4” x 3/8” steel plate, washer and nut. Cut excess threaded rods and paint galvanized steel plates and rods to match adjacent wall surface, last permitted 2009 as follows: .Jaguar (grey), flat or satin finish, Sherwin Williams. Make minor masonry repairs as necessary. Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted.
- Permit
- 16-25668-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- 4H Construction Co
- Days from application to issue
- 55
- Expires
- Mar 28, 2017
-
Permit Street Cut Other
Entergy Wr#657952 Installation of gas mains and service lines
- Permit
- 16-18985-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- Dec 10, 2016
Placed here by its tax bill number from “Solomon Pl/ N Solomon/ St Ann/ N Hennessey/ Dumaine”.