French Quarter

714 Orleans Avenue is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 10 permits on record here; the most recent, a dumpster/construction zone permit, was filed in September 2025. 6 are still open. On this block in the past year: 1 request to 311 and 114 calls to police.

Zoning
VCC-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
1,207 sq ft
Parcel
41022097

Everything on record here

10 records, newest first · 6 open

  1. Permit Dumpster/Construction Zone Permit Issued

    TRUCK PARKING - ENTIRE STREET

    Permit
    25-26566-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $375
    Days from application to issue
    6
    Expires
    Mar 8, 2026

    See this permit on One Stop

  2. Permit VCC General Work Permit Issued

    Exterior repairs to address violations cited in case 23-07956-DBNVCC, per attached materials stamped VCC approved 02/06/2026, including: Perform structural repairs at crack in service ell masonry wall, using Simpson heli-ties and VCC mortar formula. Helibond grout not approvable. Modify existing mechanical equipment platform, retain units in courtyard. Relocate rooftop unit and install railings. Replace millwork at several openings in courtyard. Provide full shop drawings for VCC review prior to fabrication and installation. Modify service ell roof, install mortar cap. Install louvered shutters in rear dormer, repair/paint dormer as needed to match existing. Repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached). Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color.

    Permit
    25-23643-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    208
    Expires
    Sep 2, 2026

    See this permit on One Stop

  3. Permit Renovation (Non-Structural) Permit Issued

    EXTERIOR REPAIRS ONLY

    Permit
    25-23643-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $44,300
    Fees
    $518
    Contractor
    Gootee Construction Inc
    Days from application to issue
    385
    Expires
    Feb 24, 2027
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  4. Permit VCC General Work Permit Cancelled

    Response to VCC Notice of Violation letter

    Permit
    21-32699-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  5. Permit Renovation (Structural) Other

    Response to VCC Notice of Violation letter

    Permit
    21-32699-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $10,000
    Fees
    $255
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  6. Permit Dumpster/Construction Zone Other

    Construction zone for fork lift.

    Permit
    20-21869-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
    Days from application to issue
    0
    Expires
    Sep 12, 2020

    See this permit on One Stop

  7. Permit VCC General Work Permit Issued

    Install one (1) new Kichler 9834WH Outdoor Flush fixture, white finish, to be centered above the main entrance and between the fascia and building facade and use with one (1) LED 14W PAR30 dimmable lamp, per application and materials received 04/28/2014, approved by the AC 05/27/14, and stamped approved 05/29/14. Note: All other lighting must be removed. All lighting must be reviewed and approved by the Vieux Carré Commission. AMMENDED 03/03/15 to allow for total of three (3) fixtures to be located each centered above a ground floor opening.

    Permit
    14-16788-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    31
    Expires
    Nov 29, 2014

    See this permit on One Stop

  8. Permit Lead-Based Paint Form Permit Issued

    Removal of exterior paint providing containment or using approved HEPA vacuum system

    Permit
    13-39090-LEAD
    Type
    Lead-Based Paint Form
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
  9. Permit VCC Paint Permit Finaled

    Repaint exterior of building to match existing, as follows: Walls: Sole (SW 6896); Shutters/Doors/Windows/Ironwork: Cascades (SW 7623); Trim: China Doll (SW 7517) Replace cast ironwork to match existing, where needed, on 2nd and 3rd floor galleries.

    Permit
    13-18209-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $6,000
    Fees
    $0
    Days from application to issue
    0
    Expires
    Dec 12, 2013

    See this permit on One Stop

  10. Permit Building

    RE-ROOF (COMMERCIAL) MIXED OCCUPANCY REROOFING EXISTING 4-STY MIXED USE BUILDING AS PER VCC #010330.

    Permit
    B01001702
    Type
    Building
    Days from application to issue
    0