French Quarter
427 Royal Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 60 permits on record here; the most recent, a VCC general work permit, was filed in May 2025. 42 are still open. On this block in the past year: 7 requests to 311 and 57 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 4
- Lot size
- 7,317 sq ft
- Parcel
- 41022185
Everything on record here
60 records, newest first · 42 open
-
Permit VCC General Work Permit Issued
To correct work without permit and demoition by neglect violations, per attached materials stamped VCC approved 10/15/2025, including: Replace balcony decking per attached VCC typical detail sheet.Paint top and sides medium gray, paint underside white. Replace roof drain at Royal-side sidewalk. Remove top bar and closer at alcove gate. Reinstall existing shutters and install new shutters to match existing as needed. Remove vinyl windows and install new Spanish cedar or mahogany windows with true divided lites and single glazing. All millwork to match existing in size, profile, dimension, detail, attachment, function, operation, reveal, color, material and finish. Repair stucco as indicated, per VCC mortar and stucco handout.
- Permit
- 25-16524-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 138
- Expires
- Apr 15, 2026
-
Permit Renovation (Non-Structural) Permit Issued
Modifications to a front vestibule gate and roof drain discharge.
- Permit
- 25-16524-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $50,904
- Fees
- $375
- Contractor
- Mobile Crushing Solutions LLC
- Days from application to issue
- 265
- Expires
- Aug 19, 2026
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Cancelled
“Non-structural renovations to exterior walls, windows, shutters, and balconies on the front, sides, and rear façade of primary and rear service building. Installation of new mechanical equipment screening along rear property line.”
- Permit
- 25-13846-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Permit Cancelled
“Non-structural renovations to exterior walls, windows, and balconies on the front, sides, and rear façade of primary and rear service building. Installation of new mechanical equipment screening along rear property line.”
- Permit
- 25-13846-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $145
- Contractor
- Mobile Crushing Solutions L.L.C.
- Application submitted
-
Permit VCC General Work Other
To install new steel gates in the center alcove of the ground floor of the Royal St. elevation as per Architecture Committee approval of 05/08/18 and final materials stamped VCC approved 09/06/2022. Gate to be made with 5/8” square steel pickets with pyramidal cut tips, turned on 45 degree angle so edge is perpendicular to gate. Paint black, gloss. Install 12" x 12" discharge door with stucco finish and piano hinge for rear roof drainage, paint yellow to match adjacent wall surface.
- Permit
- 22-22315-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 41
- Expires
- Mar 6, 2023
-
Permit Renovation (Non-Structural) Permit Issued
To install new steel gates in the center alcove of the ground floor of the Royal St. elevation as per Architecture Committee approval of 05/08/18 and final materials stamped VCC approved 09/06/2022. Gate to be made with 5/8” square steel pickets with pyramidal cut tips, turned on 45 degree angle so edge is perpendicular to gate. Paint black, gloss. Install 12" x 12" discharge door with stucco finish and piano hinge for rear roof drainage, paint yellow to match adjacent wall surface. ***no lockset is to be installed on gate
- Permit
- 22-22315-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $203
- Days from application to issue
- 79
- Expires
- Apr 12, 2023
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit VCC Paint Permit Issued
Masonry to be repointed where needed using a mortar mix Stucco will be retained as often as possible. All paint to match exisitng To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. Doing so will result in a STOP WORK ORDER being placed Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable
- Permit
- 22-22295-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 4
- Expires
- Jan 29, 2023
-
Permit Electrical Service / Circuit / Feeder Other
install 60AMP disconnect on Verizon small cell pole
- Permit
- 22-21233-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,400
- Fees
- $67
- Contractor
- Brandon Michael Descant
- Application submitted
- Application review
Placed here by its map location from “460 Royal St”.
-
Permit VCC General Work Other
To address violations cited in case 22-00753-DBNVCC, per attached materials stamped VCC approved 03/11/2022: Remove all vinyl windows and install new Spanish cedar or mahogany windows with true divided lites and single glazing. Restore wood head/jamb/sill as needed to match existing historic millwork. Sashes must be installed at same depth within wall as previous, and opening sizes are not to be altered. Muntin profile to match existing historic millwork. Repair missing muntin at first floor storefront. Install lightweight metal flap with piano hinge over PVC drain at sidewalk. Paint yellow to match existing millwork. Reinstall handrail and shutters where missing on rear elevation. Remove secondary non-historic downspouts on Royal elevation. Repair copper downspout to match existing. Repair/replace copper half-round gutters on service ell to match existing. Repair cracked stucco using VCC stucco formula (attached), to match existing finish. Repair/replace deteriorated trim and/or fascia at gallery to match existing. Paint white, semigloss.
- Permit
- 21-18879-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 255
- Expires
- Sep 11, 2022
-
Permit Renovation (Non-Structural) Application Accepted
renovations to the exterior of 427-433 royal street to correct VCC violations cited on May 20th, 2021. Remove vinyl windows and replace with wood windows with true divided lites. add cover flap to pvc pipe on from of building. add wooden muntin to store front at 429. replace twisted gutters. repairs to balconies and reattach handrails as necessary. new proposal for metal security gate at entract for 431 royal.
- Permit
- 21-18879-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $128
- Application submitted
-
Permit Attached Sign Application Accepted
To retain one (1) double-faced PVC sign to read "LolaNOLA" per drawings stamped VCC approved 07/06/2021: • Sign will measure: 30" x 7.88" x 6mm thickness • Sign will hang from existing bracket to left of entrance at 429 Royal • Sign will have a white background with teal and brown lettering • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 19-35368-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $325
- Contractor
- Vivid Ink Graphics
- Application submitted
-
Permit VCC General Work Other
To retain one (1) double-faced PVC sign to read "LolaNOLA" per drawings stamped VCC approved 07/06/2021: • Sign will measure: 30" x 7.88" x 6mm thickness • Sign will hang from existing bracket to left of entrance at 429 Royal • Sign will have a white background with teal and brown lettering • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 19-35368-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 27
- Expires
- Jan 6, 2022
-
Permit VCC Paint Permit Issued
Prepare for painting by washing using a low water pressure (400 psi max) and/or light sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix to be soft with a maximum Portland cement content not to exceed 1 part to 12) and paint to match existing with Benjamin Moore St Ann St Yellow (VC-10). Masonry to be repointed as needed using a mortar mixed and applied per the VCC standards detail sheet. Stucco will be retained as often as possible.
- Permit
- 21-09216-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Oct 6, 2021
-
Permit Small Cell Installation Other
Verizon is proposing to install a small cell antenna on an existing Toro Street light pole. 20' pole to be painted by pole manufacturer. 3-5G radios mounted at 17.15' Rad Center. Non Metered pole with power delivered via underground. Fiber delivered via underground by others. Replace pole
- Permit
- 20-34833-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $2,500
- Days from application to issue
- 397
- Expires
- Feb 18, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
Placed here by its map location from “460 Royal St”.
-
Permit VCC Paint Permit Issued
To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Remove and repair stucco where necessary using the VCC approved mortar mix applicant wil retain as much existing stucco as possible. Paint to match existing Benjamin Moore St Ann St Yellow VC-10 extended for 6 months from 10/20/21
- Permit
- 20-29049-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Nov 22, 2020
-
Permit VCC General Work Other
Renovation to comply with VCC violations Scope of work: installing foundation vent replacing trim under balcony removing and replacing window cap off unused gutters
- Permit
- 19-31800-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Renovation to comply with VCC violations Scope of work: installing foundation vent replacing trim under balcony removing and replacing window cap off unused gutters
- Permit
- 19-31800-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,018
- Fees
- $113
- Application submitted
- Zoning review
- Application review
- Permit approved
-
Permit VCC General Work Other
Install new gray TPO to rear roof to replace deterorated existing TPO per appicaiton and materials recieved 9/5/19 and stamped VCC approved 9/13/19.
- Permit
- 19-27029-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 10
- Expires
- Mar 13, 2020
-
Permit Renovation (Non-Structural) Other
Power wash roof, Install water based emulsion color black, Install grey coating.
- Permit
- 19-27029-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $31,850
- Fees
- $330
- Application submitted
Placed here by an address range from “431-433 Royal St”.
-
Permit Renovation (Non-Structural) Other
Remove/replace bath and kitchen, change outlets,change ceiling fans,paint entire apartment. Remove/replace tub and vanity with shower. Replace hot water heater. Interior repairs.
- Permit
- 19-12061-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $26,968
- Fees
- $195
- Contractor
- Foy Brian
- Days from application to issue
- 0
- Expires
- Oct 16, 2019
- Application submitted
- Application review
- Zoning review
- Permit approved
- Issue date
-
Permit VCC Paint Permit Issued
Walls...,pale yellow, flat finish Shutters...,dark green, semigloss. Final color to have appearance of dark green and not black. Trim...,white semigloss Ironwork…black
- Permit
- 18-05485-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Aug 15, 2018
-
Permit VCC Sign Permit Issued
To install one (1) double-faced wood sign to read “Osterhold & Boudreaux Gallery and Studio” per drawings submitted on 05/27/17 & stamped VCC approved 05/30/17 Sign will measure: 18" x 18" x 3/4" thickness, not to exceed 360 sq. in. per side Sign will hang on chains, perpendicular to the street & centered above the door, from a new 30" steel bracket with 3" ball finial (see attached), painted black, gloss. Sign will have a red background with white and black lettering. No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 17-09960-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 64
- Expires
- Nov 30, 2017
-
Permit Attached Sign Other
Sign
- Permit
- 17-09960-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $325
-
Permit Dumpster/Construction Zone Other
Dumpster in parking lane in front of 427-31 Royal for 10 days beginning 11/21/16 and ending on 11/30/16. A scaffold shall extent to dumpster without blocking public rigth-of-way. Permit is extended for 7 days to 12/7/2016
- Permit
- 16-38552-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $485
- Days from application to issue
- 0
- Expires
- May 21, 2017
Placed here by an address range from “427-31 Royal St”.
-
Permit VCC General Work Permit Issued
To install new steel gates in the center alcove of the ground floor of the Royal St. elevation as per Architecture Committee approval of 05/08/18 and final materials stamped VCC approved 05/29/18 Gate to be made with 5/8” square steel pickets with pyramidal cut tips Pickets to be punched through 3/8” x 1 -1/4” steel flat bars Pickets to be spaced 3” on center Gate to be painted black
- Permit
- 16-33859-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 574
- Expires
- Nov 29, 2018
-
Permit VCC General Work Permit Issued
To repair/rebuild Conti elevation wall of the main building as per Architectural Committee approval of 12/13/16, final plans received 12/05/16, and stamped VCC approved 12/19/16. Work includes but is not limited to: • Removing vertical sections of bricks from between the in-place shoring • Rebuilding the wall in sections, utilizing Helific-CemTies every 16” in a staggered patter to tie the rebuilt sections in with the interior wythe of brick • Removing the shoring as work progresses across the wall • Stuccoing and finishing the wall to match the adjacent surface NOTE: Ties to be placed in mortar joints as much as possible. Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All mortar and stucco to be mixed according to the VCC standard detail sheet (attached).
- Permit
- 16-35059-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 48
- Expires
- Jun 19, 2017
-
Permit VCC General Work Permit Issued
• Remove existing slate roofing material from main and slave quarter buildings • Repair and/or replace underlayment as necessary • Install new natural slate (grey/green), using copper nails • Install/repair half round copper gutters and flashing • Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Metal cap-flashing on the parapets is not allowed • Install new TPO liner in internal gutter All work as per scope of work submitted 10/24/16 and stamped VCC approved 11/04/16. Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. All work must conform to standard VCC policies & guidelines.
- Permit
- 16-35270-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- May 4, 2017
-
Permit Renovation (Non-Structural) Other
Re-roof: remove slate and replace with natural slate
- Permit
- 16-35270-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $86,112
- Fees
- $743
- Contractor
- NuWorx LLC
- Days from application to issue
- 18
- Expires
- May 11, 2017
Placed here by an address range from “429-31 Royal St”.
-
Permit Renovation (Structural) Inspection Phase
Remove the damaged wall in sections. Rebuild using bricks and mortar that comply with Vieux Carre guidlines. Install Helifix Cem Tie masonry anchors.
- Permit
- 16-35059-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $22,500
- Fees
- $353
- Contractor
- Abry Brothers, Inc.
- Days from application to issue
- 70
- Expires
- Jun 30, 2017
-
Permit Renovation (Non-Structural) Other
Proposed new iron gate installed within the center bay entry alcove as per drawings submitted.
- Permit
- 16-33859-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $128
Placed here by an address range from “431 Royal St, 427 Royal St, 427 Royal St Unit B, 427 Royal St Unit C, 427 Royal St Unit D, 427 Royal St Unit E, 427 Royal St Unit F, 427 Royal St Unit G, 427 Royal St Unit H, 427 Royal St Unit I, 429 Royal St, 433 Royal St”.
-
Permit VCC General Work Permit Issued
Emergency temporary shoring to the southwest facing wall at the second level
- Permit
- 16-26729-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 23, 2017
-
Permit Renovation (Structural) Inspection Phase
Emergency temporary shoring to the southwest facing wall at the second level
- Permit
- 16-26729-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $16,000
- Fees
- $210
- Contractor
- Abry Brothers, Inc.
- Days from application to issue
- 8
- Expires
- Feb 23, 2017
-
Permit VCC Paint Permit Issued
Remove deteriorated floor boards and install new 5/4x4 S2S T&G floorboards, as per VCC Standard Detail Sheet No. 12 (attached) All repair/replacement work shall match existing in color, size, material, detail, profile and exposure Gallery decking...grey to match existing
- Permit
- 14-36386-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 10
- Expires
- May 20, 2015
-
Permit Renovation (Non-Structural) Permit Cancelled
Construct a deck on flat roof of 431 Royal St per sketch and VCC approval.
- Permit
- 14-27555-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,500
- Fees
- $120
-
Permit VCC General Work Permit Cancelled
Construct a deck on flat roof of 431 Royal St per plans and VCC approval.
- Permit
- 14-27556-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Permit Cancelled
• Remove deteriorated floor boards, stringers, and fascia boards. • Install new 3"x4" beaded stringers, 5/4x4 S2S T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). • All repair/replacement work shall match existing in color, size, material, detail, profile and exposure • To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: • Gallery deck and underside…White NOTE: Permit never picked up. (NGA - 2.3.15)
- Permit
- 13-46360-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 1
- Expires
- Jun 4, 2014
-
Permit VCC General Work Other
Historical Import Type: Enforcement VCC Permit General User: TMCLEOD Tracking: 86190121905 Status: Permit Issued Status Date: 5/22/2012 12:00:00 AM Owner: Martin Lawrence Gallery Owner Address: 433 Royal Street, New Orleans, LA 70130 Owner Phone: Owner Edited By: 5/22/2012 by TMCLEOD To do the following work according to VCC guidelines: -Replace one (1) HVAC condensing units (Trane- model #4TTB3060D). -Unit to measure 42.4H x 35.1W x 38.7D. -Unit to be installed in same manner and location as existing unit. Note: No other work is approved under this permit.
- Permit
- VCCP-12-0473
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit General Mechanical Other
Work Descripton: REPLACE CONDENSER. (#VCCP-12-0473) KENNETH ROBERT (#043311) / GALLERY Historical Import Type: Permits Mechanical Commercial General Mechanical User: JOSLEE Tracking: 86134068180 Status: Closed Status Date: 5/30/2012 12:00:00 AM Owner: 427-33 Royal Street, LLC Owner Address: 701 Edwards Ave, New Orleans, LA 70123 Owner Edited By: 3/19/2012 by JOSLEE
- Permit
- 12MCH-02148
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $51
- Contractor
- Robert Refrigeration
- Days from application to issue
- 0
- Expires
- Sep 19, 2012
-
Permit General Mechanical Certificate Of Completion - Issued No Meter
..ROBERT REFRIGERATION - KENNETH ROBERT - - CK#040294 - A/C COND -
- Permit
- 09MCH-05097
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $48
- Contractor
- Robert Refrigeration
- Days from application to issue
- 5
-
Permit General Mechanical Application Acceptance - Approved
PAT WAGUESPACK JR PLBG - BRADLEY CARLTON - - CK#2024 - METER OUT OVER 6 MOS
- Permit
- 09MCH-02859
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Pat Waguespack Jr Plbg.
- Days from application to issue
- 5
-
Permit General Mechanical Inspection - Completed
line & 2 wh pat #1973
- Permit
- 09MCH-01808
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $55
- Contractor
- Pat Waguespack Jr Plbg.
- Days from application to issue
- 5
-
Permit Electrical Service / Circuit / Feeder Application Acceptance - Approved
RENOVATIONS
- Permit
- 08ELC-25060
- Type
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $186
- Contractor
- Pizzeck A/C & Elec.
Placed here by the building address from “431 Royal St 1”.
-
Permit General Mechanical Inspection - Completed
REPLACE 18-TON A\C . KENNETY ROBERT (#036038)
- Permit
- 05MCH-05053
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $48
- Contractor
- Robert Refrigeration
- Days from application to issue
- 5
-
Permit Mechanical Annual Renewal Active
- Permit
- 03MCH-06130
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $15
-
Permit Mechanical Renewal Active
- Permit
- 03MCH-06131
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-06991
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1
- Permit
- S04000431
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1
- Permit
- S04000233
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1
- Permit
- S04000234
- Type
- Sign
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2003 PAID FOR 1
- Permit
- S03000662
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2003
- Permit
- S03000107
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE
- Permit
- S02000555
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2002 PAID
- Permit
- S02000071
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000800
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000401
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000313
- Type
- Sign
- Days from application to issue
- 0
-
Permit Building
ALTERATION MIXED OCCUPANCY THIS IS A DUMMY PERMIT FOR INSTRUCTIONAL PURPORPOSES ONLY----- DO NOT USE FOR ANY REASON NO WORK NO USE AND OCCUPANCY
- Permit
- B96001398
- Type
- Building
-
Permit Building
ALTERATION MIXED OCCUPANCY YET ANOTHER BAD PERMIT TO BE DELETED
- Permit
- B96001399
- Type
- Building
-
Permit Building
ALTERATION MIXED OCCUPANCY XXXX
- Permit
- B96001403
- Type
- Building
-
Permit Building
ALTERATION MIXED OCCUPANCY XXX
- Permit
- B96001404
- Type
- Building