603 Royal Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 22 permits on record here; the most recent, a VCC general work permit, was filed in October 2025. 10 are still open. On this block in the past year: 7 requests to 311 and 53 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 1,814 sq ft
- Parcel
- 41022204
Everything on record here
22 records, newest first · 10 open
-
Permit VCC General Work Permit Issued
Tuck point 2nd and 3rd floor masonry wall using VCC approved mortar mix. To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Lath or adherents of any kind are prohibited unless preapproved by VCC staff prior to installation. Replace any damaged balcony wood flooring ( to match exisitng). the VCC does not allow sythetic wood products. Prep and paint doors, shutters, balcony floors, cielings and iron railings (all paint to match existing).
- Permit
- 25-30020-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- Apr 6, 2026
-
Permit Renovation (Non-Structural) In Review
Tuck point front masonry wall at 2nd and 3rd floor. VCC approved mortar mix will be used. Replace any damaged balcony flooring boards as needed. Prep and paint doors, shutters, balcony flooring and ceilings and iron railings. Existing colors to remain. Doors and trim white, Shutters- Essex Green, Iron work- Black.
- Permit
- 25-30020-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $28,883
- Fees
- $398
- Contractor
- LEO A. DUVERNAY, L.L.C.
- Application submitted
- Application review
- Zoning review
-
Permit VCC Paint Other
ALL WORK TO MATCH EXISITNG On St. Peter St. facade, repair & paint four pairs of fixed louvered shutters on the third floor; Reattach & repair damaged sections of downspouts and paint unpainted areas of downspout - on St. Peter side of building.
- Permit
- 25-08557-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Bywater Woodworks Inc
- Days from application to issue
- 3
- Expires
- Sep 21, 2025
-
Permit VCC General Work In Review
Request to retain existing PVC plumbing pipes on rear of house.
- Permit
- 24-08418-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Request to retain existing PVC plumbing pipes on rear of house.
- Permit
- 24-08418-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $180
- Application submitted
- Zoning review
-
Permit VCC Sign Application Accepted
Sign for business, Toulouse Royale Gifts @ 603 Royal St Store name and logo
- Permit
- 23-28750-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Attached Sign Other
Sign for business, Toulouse Royale Gifts @ 603 Royal St Store name and logo
- Permit
- 23-28750-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $98
- Application submitted
-
Permit VCC General Work Permit Issued
***ALL WORK ON FRONT FACADE To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.
- Permit
- 23-25571-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Mar 22, 2024
-
Permit Renovation (Non-Structural) In Review
Minor masonry work to facade of building.
- Permit
- 23-25571-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,650
- Fees
- $210
- Application submitted
- Zoning review
-
Permit VCC General Work In Review
• Remove existing Fire Free Plus roofing material • Repair and/or replace underlayment as necessary • Install new natural slate (grey/green), using copper nails • Install/repair half round copper gutters and flashing • Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 21-26838-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Application Accepted
Roof replacement. Install natural Slate roof and all new copper flashings and box valleys. Roof shingles are 12" x 18" Slate semi weathering.
- Permit
- 21-26838-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $31,963
- Fees
- $330
- Application submitted
-
Permit Electrical Service / Circuit / Feeder Permit Issued
increase and relocate service
- Permit
- 19-37415-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $17,885
- Fees
- $85
- Contractor
- Fred J Vanlangendonck III
- Days from application to issue
- 11
- Expires
- Jun 3, 2020
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Electrical Service / Circuit / Feeder Permit Issued
increase and relocate service
- Permit
- 19-37414-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $17,885
- Fees
- $85
- Contractor
- Fred J Vanlangendonck III
- Days from application to issue
- 11
- Expires
- Jun 3, 2020
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
Placed here by the building address from “605 Royal St, apt 3 flr”.
-
Permit Electrical Service / Circuit / Feeder Permit Issued
increase and relocate service
- Permit
- 19-37413-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $17,885
- Fees
- $100
- Contractor
- Fred J Vanlangendonck III
- Days from application to issue
- 11
- Expires
- Jun 3, 2020
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Permit Cancelled
Non-structural renovation to units B&C in multi-family dwelling. Scope of work includes plumbing, electrical, drywall, kitchen, and bathroom repairs. No exterior work.
- Permit
- 19-34730-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Apr 30, 2020
-
Permit Renovation (Non-Structural) Other
Non-structural renovation to residential units B&C in mixed-use structure . Scope of work includes plumbing, electrical, drywall, kitchen, and bathroom repairs. No exterior work.
- Permit
- 19-34730-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $120,220
- Fees
- $786
- Contractor
- Duvernay Leo
- Application submitted
- Application review
- Zoning review
-
Permit VCC General Work Other
Tuck point Royal St. elevation as needed with VCC approved mortar. Chimney- Repair masonry and tuck point chimney as needed using VCC approved mortar and stucco mix. Replace existing exposed PVC plumbing pipes on rear of 605 Royal St. with cast iron pipe with no hub fittings. To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. *****Business Signs- To be resolved by tenant. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspe
- Permit
- 19-25326-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 14, 2020
-
Permit Renovation (Non-Structural) Other
Repairs as per VCC violations as listed below: Brick Work- Tuck point Royal St. elevation as needed with VCC approved mortar. Chimney- Repair masonry and tuck point as needed. Plumbing- Replace existing exposed PVC plumbing pipes on rear of 605 Royal St. with cast iron pipe with no hub fittings. Business Signs- To be resolved by tenant.
- Permit
- 19-25326-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $18,600
- Fees
- $155
- Application submitted
-
Permit Street Cut Other
Install 2 4" conduit services to building
- Permit
- 19-24667-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $274
- Contractor
- NOLA Construction Services LLC
- Days from application to issue
- 22
- Expires
- Feb 28, 2020
-
Permit Renovation (Non-Structural) Other
Non-structural repairs to multi-family dwelling. Repairs include electrical only. No exterior work allowed under this permit.
- Permit
- 19-24659-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $23,150
- Fees
- $180
- Contractor
- Leo A Duvernay, LLC
- Days from application to issue
- 0
- Expires
- Feb 6, 2020
- Application submitted
- Application review
- Zoning review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Finaled
Historical Import Type: Enforcement VCC Permit General User: HIRVIN Tracking: 86169203877 Status: Permit Issued Status Date: 1/26/2012 12:00:00 AM Owner: Su Lu Ette De LLC Owner Address: 5805 Argonne Blvd, New Orleans, LA 70124 Owner Edited By: 1/26/2012 by HIRVIN •Install temporary bracing under balcony/gallery structure, starting Friday, February 10, 2012 and removed no later than Thursday, February 23, 2012. •Temporary bracing must be installed in a manner that does not damage the existing balconies, galleries, facades, sidewalks, etc., and does not obstruct the sidewalk. •The attachment of temporary supports by welding, bolting, screwing, etc., to the balcony/gallery structure is not permitted. •Type of support system must be reviewed, approved, and have permits issued by the Department of Safety and Permits, Department of Public Works, and any other agency with jurisdiction.
- Permit
- VCCP-12-0064
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 06ELC-43044
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Technical System Specialties
- Days from application to issue
- 10