French Quarter
1013 Royal Street is in French Quarter, zoned VCR-2 (French Quarter residential, with somewhat higher density than VCR-1). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 13 permits on record here; the most recent, a VCC general work permit, was filed in September 2025. 7 are still open. There were 2 past code enforcement cases, the latest in June 2012, all closed. On this block in the past year: 5 requests to 311 and 68 calls to police.
- Zoning
- VCR-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 6
- Lot size
- 4,073 sq ft
- Parcel
- 41022254
Everything on record here
15 records, newest first · 7 open
-
Permit VCC General Work Permit Issued
Remove existing roofing material Repair and/or replace underlayment as necessary Install new 12” x 18” natural Vermont slate (Hlltop grey/green), using copper nails Install/repair half round copper gutters, drip edge and flashing where necessary Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Metal cap-flashing on the parapets or chimneys is not allowed ***traditional masonry cap must be istalled on parapet per VCC guidelines remove and replace jacks and vents, to be located in same locatio Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 25-29677-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 7
- Expires
- Apr 3, 2026
-
Permit Residential Re-Roofing Permit Issued
Remove existing roofing · Remove and replace jacks and vents, all in same locations · Remove felt · Install new copper drip edge · Install new copper flashing · Install ice and water shield on entire roof · Install real slate shingles with copper nails · Reinstall existing terra cotta ridge caps or replace with new to match existing. Complete masonry cap work on parapet walls per vcc guidelines. Work to be completed by Spectrum Commercial/Spectrum Roofing Geo-Tagged photos should be taken and uploaded at every stage in lieu of inspections as indicated on Nola.gov.
- Permit
- 25-29677-ROOF
- Type
- Residential Re-Roofing
- Work
- Residential Re-Roofing
- Estimated cost (applicant’s figure)
- $0
- Fees
- $90
- Contractor
- Spectrum Commercial Construction LLC
- Days from application to issue
- 14
- Expires
- Apr 10, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Renovation (Non-Structural) Other
· Remove existing roofing · Remove and replace jacks and vents, all in same locations · Remove felt · Install new copper drip edge · Install new flashing · Install ice and water shield on entire roof · Install real slate shingles with copper nails · Reinstall existing terra cotta ridge caps or replace with new to match existing
- Permit
- 25-29115-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $45,500
- Fees
- $350
- Application submitted
-
Permit VCC General Work Permit Issued
remove existing roofing remove and replace jacks and vents, all in same location remove one layer of felt install new copper drip edge install new flashing insatll ice and water shield on entire roof install READY SLATE shingles per manufacturer's specifications reinstall existing terra cotta ridge caps or realce with new to match existig Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs..All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 24-35439-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 58
- Expires
- Jul 29, 2025
-
Permit Renovation (Non-Structural) Other
remove existing roofing remove and replace jacks and vents, all in same location remove one layer of felt install new copper drip edge install new flashing insatll ice and water shield on entire roof install READY SLATE shingles per manufacturer's specifications reinstall existing terra cotta ridge caps or realce with new to match existig Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs..All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 24-35439-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $23,000
- Fees
- $353
- Contractor
- Nodis Constructions, L.L.C.
- Application submitted
- Zoning review
-
Permit VCC Paint Other
To make minor repairs and paint to match as per materials stamped VCC approved 11/15/2023. Work includes: • Removal of any vegetation growing from the building • Cutting spitters/removing spitter extensions from two gutter spitters on the Royal St. elevation gutter • Repoint the masonry wall as per VCC standard details (attached) • Repair missing shutter slats to match existing • Paint previously pained masonry, shutters, soffit, fascia, and trim to match existing colors and sheens NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 23-30082-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Nodis Constructions
- Days from application to issue
- 14
- Expires
- May 15, 2024
-
Permit Dumpster/Construction Zone Other
We would like to place a 30 yard dumpster for trash removal.
- Permit
- 17-16192-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $100
- Days from application to issue
- 7
- Expires
- Nov 16, 2017
-
Permit Renovation (Non-Structural) Permit Cancelled
replace a few missing bricks approximately 2 dozen using VCC standard mortar mix and paint with approved colors already being used for exterior walls. apply/repair flashing on exiting scheduled "brown building" roof which is a small storage shed. paint touch up with approved existing wall color if needed anywhere.
- Permit
- 15-20352-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $90
-
Permit VCC General Work Permit Issued
Remove broken window panes and replace with new glass
- Permit
- 15-14509-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $100
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Nov 13, 2015
-
Permit VCC Paint Permit Issued
Walls: Valspar 4007-1B "Autumn Fog" flat or satin finish Wooden elements including doors (excluding front doors) windows, frames, shop windows, fascia/soffit/outriggers of gallery: Benjamin Moore #1065 "Wood Ash" semigloss Shutters: Benjamin Moore #677 "Azure Water" semigloss Front doors and steps: Benjamin Moore #1299 "Crimson" semigloss Ironwork: Black
- Permit
- 15-13815-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Nov 13, 2015
-
Permit VCC General Work Permit Issued
install exterior security cameras IR Dome Camera Model 2060 IR 5" diameter base 1.14.15 - email sent to applicant
- Permit
- 15-00548-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- Jul 14, 2015
Placed here by an address range from “1013 Royal St, 1019 Royal St, 1021 Royal St”.
-
Permit Renovation (Structural) In Review
install exterior security cameras
- Permit
- 15-00548-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $500
- Fees
- $98
-
Permit VCC General Work Permit Issued
- Repair deteriorated masonry on rear service building using VCC approved mortar mix (below) - Repair hole in tar paper roof on service building storage structure to match existing - Re-align and secure column of balcony on service building - To service structure balcony: Remove deteriorated floor boards, stringers, and fascia boards, and install new 3"x4" beaded stringers, 5/4x4 S2S T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). All repair/replacement work shall match existing in color, size, material, detail, profile and exposure - Replace broken roof ridge tiles on masonry wall of service building adjacent to 1019 Royal to match existing - Remove vegetation growing on main cottage in courtyard. - Remove colored light bulbs (green) installed in hanging fixtures at front facade - Remove light fixture mounted on upriver door frame of front facade Mortar: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. permit reissued 7.9,15
- Permit
- 14-21421-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 16
- Expires
- Jan 10, 2015
-
Code enforcement Case 12-06559-PNBL Closed
The property was inspected on 06/23/2012 with a finding of "Violation: No WIP". The file was subsequently closed.
- Inspection: Inspection Violation: No WIP
- Violation: 28-31 Doors
- Violation: 28-12 Foundation
The city links this case to permit 25-29677-VCGEN.
-
Code enforcement Case ENVHADJ-20044575SN Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 25-29677-VCGEN.