French Quarter
1212 Royal Street is in French Quarter, zoned VCR-2 (French Quarter residential, with somewhat higher density than VCR-1). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 20 permits on record here. 15 are still open. There were 4 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 9 requests to 311 and 276 calls to police.
- Zoning
- VCR-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 6
- Lot size
- 6,654 sq ft
- Parcel
- 41022287
Everything on record here
24 records, newest first · 15 open
-
Permit Permit Finaled
Night of a 1,000 Mona Lisa's Block Closure - 1212 Royal St 8/16/2025 Block Closure: 1200 Royal (between Barracks & Gov Nichols St) 5:00 PM - 9:00 PM 8/16/2025 No admission. No outside sales. Dj, sound amplification outdoors. 1,000 Attendees Event Hours: 5:00 PM - 9:00 PM ***Block Closure Law Enforcement Detail Must Be Present.*** We are looking to have a community-based event in support of a beloved local restaurant, Mona Lisa's on August 16th from 5 p.m. to 8:30 p.m. The event will be in celebration of the restaurant, who is facing a removal from the building, due to new owners. The restaurant has been a valuable member of the French Quarter and a queer affirming space for over thirty five years. The event is intended to show support, both moral and financial for the restaurant and their staff. We are looking to have a possible street fair or block party aesthetic, if permits allow. If not, we will gather on the sidewalks. As of now, the event has a reach of over 1,200 people that are interested in attending the event.
- Permit
- 25-23640-SPMA
- Days from application to issue
- 24
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Issued
Remove existing Fire Free Plus roofing material Repair and/or replace underlayment as necessary Install new 12” x 18” natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Metal cap-flashing on the parapets or chimneys is not allowed **front building only remove siding on walls newar roof surface, instill step flashing and reinstall existing siding. ALL siding is to be natural wood. Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 23-26453-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Apr 4, 2024
-
Permit Renovation (Non-Structural) Permit Issued
Roof Replacement.
- Permit
- 23-26453-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $205,135
- Fees
- $1,944
- Days from application to issue
- 59
- Expires
- May 27, 2024
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit Dumpster/Construction Zone Other
- Permit
- 20-31105-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $70
-
Permit VCC Paint Permit Issued
shutters and doors: SW Ivay Wall (to match existing), semigloss windows and trim: White Satin PPU18-08, semigloss Walls: Gray, (see attached for exact formula specificaitons), flat or eggshell
- Permit
- 17-17825-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 37
- Expires
- Apr 5, 2018
-
Permit VCC General Work Permit Issued
To perform masonry, header, and balcony work as per materials stamped VCC approved 09/15/17. Work includes but is not necessarily limited to: Replacing the header above second floor door on the Royal St. elevation, closest to the Governor Nicholls property line, with new 6x6 header Painting headers to match existing conditions…white, semigloss Repointing masonry above second floor door on the Royal St. elevation, second opening from the Barracks property line, utilizing the VCC standard detail sheet (attached) Repairing/replacing stucco above both repaired/replaced headers utilizing the VCC standard detail sheet (attached) Remove existing balcony deck boards and stringers Install new 3x4 beaded stringers and new 5/4 x 4 T&G deck boards as per VCC Standard detail sheet no. 12 (attached) Paint deck boards and associated components... Underside of balcony/fascia/sleepers…white, semigloss Tops and sides of deckboards…grey, semigloss Remove window AC unit from transom on the Royal St. elevation and reinstall previously existing transom window NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 17-29795-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 17
- Expires
- Mar 15, 2018
-
Permit VCC General Work Permit Issued
To remove broken glass from a total of three (3) window lites. To install three (3) new panes of glass to replace broken glass. Glass to be 1/8” thick and clear. Windows to be glazed using glazing putty, once “skin” has formed on glazing, glazing to be primed with oil based primer and painted white to match existing.
- Permit
- 16-17655-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Nov 30, 2016
-
Permit Renovation (Non-Structural) Other
Repair 3 broken window panes.
- Permit
- 16-17655-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $75
- Fees
- $98
-
Permit VCC General Work In Review
Stabilize second floor brick header, cornice and parapet by installing temporary pressure treated wood lintel and bricks within missing lintel space (lintel removed without benefit of VCC review or approval), at middle window of left, Barracks-side bay. Perform minor exploratory demolition at second floor lintel/header of right window of right, Gov. Nicholls-side bay, evaluating extent of damage and possible lintel failure. Petitioner to submit application for structural renovation within 30 days for final Architectural Committee review and approval. Application to include full scope of work, corresponding engineer's report and detailed wall sections All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
- Permit
- 16-16282-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Nov 16, 2016
-
Permit VCC General Work Permit Issued
Remove deteriorated balcony floor boards, Install new 5/4x4 T&G floor boards, per VCC Standard Detail Sheet No. 12 (attached). Prime & paint deck boards prior to installation, Paint deck boards with additional coat of gray on top and sides, and paint underside white to match stringers and outriggers, after installation. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
- Permit
- 16-08006-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Sep 24, 2016
-
Permit Renovation (Non-Structural) Other
Remove 5/4 x 3 tongue& groove (t&g) deck boards (4' X 48' area) and replace with new 5/4 X 3 t&g deck boards at second floor balcony. All new boards will be primed and painted prior to installation. benjamin moore platinum gray deck paint
- Permit
- 16-08006-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $90
- Contractor
- Clarence T Jr Coleman
-
Permit VCC General Work Permit Issued
Repair stucco finish above second story window, second from the Barracks property line using VCC approved stucco formula Mortar: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent.
- Permit
- 14-35099-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 7
- Expires
- May 18, 2015
-
Permit Renovation (Non-Structural) Other
repair brick and stucco at second window. see attached.
- Permit
- 14-35099-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1,800
- Fees
- $105
-
Permit VCC General Work Permit Issued
Remove all existing, unpermitted and/or unshielded light fixtures Install three (3) Remcraft Series 102 white fixtures to the underside of the balcony, centered over the window & door openings per cut sheet submitted 09/07/14 & stamped VCC approved 09/12/14 Install three (3) Lorex (Model #LBV1521) security cameras mounted to underside of gallery per cut sheet submitted 09/02/14 & stamped VCC approved 09/12/14. Light Fixtures and cameras shall be painted to match adjacent building surface if necessary All conduit and wiring shall be placed along the inside corners of building surfaces as much as possible, such as along balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 600-800 lumens per bulb Repair second story, louvered shutters to match existing in color (Essex Green #43), size, material, detail, profile and exposure
- Permit
- 14-28451-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Mar 12, 2015
-
Code enforcement Case ENVHADJ-20041075F Closed
The property was inspected on 01/09/2004 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 25-23640-SPMA.
-
Code enforcement Case ENVHADJ-20041092F Closed
The property was inspected on 01/09/2004 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 25-23640-SPMA.
-
Code enforcement Case ENVHADJ-20041340F Closed
A hearing was held on 04/10/2009 with a result of "Dismissed". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Dismissed
The city links this case to permit 25-23640-SPMA.
-
Code enforcement Case ENVHADJ-911017SH Closed
The property was inspected on 04/10/2009 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 25-23640-SPMA.
-
Permit Mechanical Annual Inspection Completed
- Permit
- 03MCH-06450
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $22
-
Permit Sign
PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2004 PAID FOR 1
- Permit
- S04000271
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2003 PAID FOR 1
- Permit
- S03000466
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE
- Permit
- S02000450
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2001 PAID
- Permit
- S01000454
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RESTAURANT 50 PEOPLE AND OVER SIGN FEE 2000PD
- Permit
- S00000543
- Type
- Sign