French Quarter

410 Bourbon Street is in French Quarter, zoned VCE (French Quarter entertainment area, including bars and live music). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 42 permits on record here. 19 are still open. There was 1 past code enforcement case, the latest in April 2009, all closed. On this block in the past year: 4 requests to 311 and 572 calls to police.

Zoning
VCE
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
4
Lot size
3,690 sq ft
Parcel
41022416

Everything on record here

43 records, newest first · 19 open

  1. Permit Permit Application Submitted

    Non-profit group of about 35 women wearing theme-decorated corsets, sashaying, walking and handing out beads, plastic cups and plastic souvenirs, with a small, local brass band. Starting at 1:00 pm, our walking route will start in the French Quarter, at 410 Bourbon street , then go down Bourbon street, taking a right on St. Phillip, then taking another right onto Decatur street, ending at 410 Decatur Street, in the French Quarter. We have walked this same route, every Friday before Mardi Gras, from previous years in the French Quarter, sashaying under the name "Crescent City Dames." The walking parade takes about little under an hour.

    Permit
    26-20820-SPMA
    1. Application submitted
  2. Permit Electrical Vacancy Other

    Electrical Vacancy Permit

    Permit
    26-02044-EVAC
    Type
    Electrical Vacancy
    Work
    Electrical Vacancy
    Estimated cost (applicant’s figure)
    $425
    Fees
    $40
    Contractor
    Ryan Michael Lowe
    Days from application to issue
    13
    Expires
    Aug 3, 2026
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

    Placed here by the building address from “410 Bourbon St, Suite D”.

  3. Permit Electrical Vacancy Other

    Electrical Vacancy Permit

    Permit
    26-02043-EVAC
    Type
    Electrical Vacancy
    Work
    Electrical Vacancy
    Estimated cost (applicant’s figure)
    $425
    Fees
    $40
    Contractor
    Ryan Michael Lowe
    Days from application to issue
    13
    Expires
    Aug 3, 2026
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

    Placed here by the building address from “410 Bourbon St, Suite C”.

  4. Permit Electrical Vacancy Other

    Electrical Vacancy Permit for suite b

    Permit
    26-02042-EVAC
    Type
    Electrical Vacancy
    Work
    Electrical Vacancy
    Estimated cost (applicant’s figure)
    $425
    Fees
    $40
    Contractor
    Ryan Michael Lowe
    Days from application to issue
    13
    Expires
    Aug 3, 2026
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

    Placed here by the building address from “410 Bourbon St, Suite B”.

  5. Permit Electrical Vacancy Other

    Vacancy permit suite A for electrical permit

    Permit
    26-02041-EVAC
    Type
    Electrical Vacancy
    Work
    Electrical Vacancy
    Estimated cost (applicant’s figure)
    $1,700
    Fees
    $40
    Contractor
    Ryan Michael Lowe
    Days from application to issue
    13
    Expires
    Aug 3, 2026
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

    Placed here by the building address from “410 Bourbon St, Suite A”.

  6. Permit VCC General Work In Review

    Retention of metal rails, sign location, front under-balcony lighting locations, stucco courtyard service ell infill wall cladding, and 7 board wood fence atop CMU wall in courtyard.

    Permit
    24-12858-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  7. Permit Renovation (Non-Structural) In Review

    Retention of metal rails, sign location, front under-balcony lighting locations, stucco courtyard service ell infill wall cladding, and 7 board wood fence atop CMU wall in courtyard.

    Permit
    24-12858-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $25,000
    Fees
    $368
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  8. Permit VCC Security Camera Application Permit Issued

    To install one dome style security camera mounted to the underside of the balcony per cut sheet submitted & stamped VCC approved 04/05/24. Cameras shall be painted to match the attached surface or prefinished to match the attached service Cameras are to be mounted flush on the building. Conduit boxes and wires should not be visible. Mounting arms are not allowed. All wiring shall be placed in conduits and located as discretely as possible. All conduits to be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line and painted to match the adjacent surfaces. All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. The security camera is not to be attached to the granite or any other location other than the approved location All work must conform to standard VCC policies & guidelines.

    Permit
    24-08821-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $1,100
    Fees
    $0
    Days from application to issue
    10
    Expires
    Oct 5, 2024

    See this permit on One Stop

  9. Permit VCC General Work Application Accepted

    Connect sign to existing power

    Permit
    23-26210-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  10. Permit Electrical Repair / Replacement / Addition Permit Finaled

    Bar / Apartment

    Permit
    23-34291-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $875
    Fees
    $40
    Contractor
    Michael Andrew Adams
    Days from application to issue
    18
    Expires
    Jul 2, 2024
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  11. Permit Electrical Repair / Replacement / Addition Permit Cancelled

    Connect sign to existing power

    Permit
    23-26210-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $260
    Fees
    $40
    1. Application submitted
    2. Application review
    3. Permit approved

    See this permit on One Stop

  12. Permit VCC Sign Other

    Install (1) Double-Sided Neon Cabinet Sign

    Permit
    23-15025-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    45
    Expires
    Jan 17, 2024

    See this permit on One Stop

    Placed here by an address range from “410-412 Bourbon St”.

  13. Permit Attached Sign Inspection Phase

    To install one (1) double-faced neon cabinet sign to read "69 Taps Quarter Keg" per drawings stamped VCC approved 07/17/2023: • Sign will measure: 4'-0" x 3'-2" x 14" • Sign will hang perpendicular to the street, centered above the front entry door • Sign will hang from chains from the existing balcony • Sign will have a brown background with green, yellow and orange lettering • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.

    Permit
    23-15025-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $165
    Contractor
    Pro Signs & Graphics
    Days from application to issue
    70
    Expires
    Feb 11, 2024
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

    Placed here by an address range from “410-412 Bourbon St”.

  14. Permit VCC General Work Other

    Renovations to abate violations cited in VCC cases 21-03244-DBNVCC and 22-01278-DBNVCC, per attached materials stamped VCC approved 07/05/2022. NOTE: All VCC notes on drawings are required. Contact VCC prior to any deviations from approved materials. All stucco and mortar to be VCC formulas, per attached. Prepackaged mixes are NOT allowed. Contact VCC staff for inspection or provide photos of areas where exploratory demolition is undertaken before proceeding with work. Replace third floor windows on front and rear elevation of main building with new six-over-six double-hung windows. All new millwork must be single glazed with true divided lights. Color, size, material, reveal, detail, profile and exposure to match existing. Remove existing asphalt roofing material. Repair and/or replace underlayment as necessar. Install new 12" x 18" natural slate (grey/green), using copper nails. Install/repair half round copper gutters and flashing. Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed

    Permit
    21-31193-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    235
    Expires
    Jan 5, 2023

    See this permit on One Stop

  15. Permit Renovation (Non-Structural) Occupancy

    Exterior renovations in response to VCC violations. TEMPORARY CERTIFICATE OF OCCUPANCY ISSUED ON 4-18-24 FOR 90 DAYS

    Permit
    21-31193-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $187,000
    Fees
    $1,898
    Days from application to issue
    280
    Expires
    Feb 12, 2023
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  16. Permit VCC General Work Permit Cancelled

    General Renovation Needed

    Permit
    21-17752-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  17. Permit Renovation (Structural) Permit Cancelled

    General Renovation Needed

    Permit
    21-17752-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $200,000
    Fees
    $1,890
    1. Application submitted

    See this permit on One Stop

  18. Permit VCC General Work Permit Cancelled

    Address VCC violations: scope of work will be attached in separate document for VCC review.

    Permit
    21-07483-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  19. Permit Renovation (Non-Structural) Permit Cancelled

    Address VCC violations: scope of work will be attached in separate document for VCC review.

    Permit
    21-07483-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $0
    Fees
    $90
    1. Application submitted

    See this permit on One Stop

  20. Permit Street Cut Other

    Install Fiber Optic Cable only for Homeland Security Cameras.

    Permit
    19-17959-RSTC
    Type
    Street Cut
    Work
    Street Cut
    Estimated cost (applicant’s figure)
    $0
    Fees
    $112
    Contractor
    Uniti Fiber

    See this permit on One Stop

  21. Permit VCC General Work Permit Cancelled

    Exterior repairs to address VCC violations.

    Permit
    18-10004-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  22. Permit Renovation (Non-Structural) Permit Cancelled

    Exterior repairs to address VCC violations.

    Permit
    18-10004-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $4,850
    Fees
    $128
    Contractor
    Earth Inc
    1. Application submitted

    See this permit on One Stop

  23. Permit VCC General Work Permit Cancelled

    To remove all foliage growth from the masonry To remove using hand tools, without expanding the existing joints between bricks, any deteriorated or failing mortar To repoint the masonry utilizing the VCC mortar formula (alternatively a mortar analysis may be submitted to the VCC for approval of a mortar mix designed to exactly imitate the existing mortar) Replace all severally damaged bricks with brick carefully selected to match existing as close as possible in color, size, material, porosity, detail, profile and exposure Reconstruct damaged parapets with brick to match existing All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations but additional violations exist that are not addressed by this permit. Applicant to submit additional information to address other outstanding violation. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work. RE-ISSUE January 30, 2018

    Permit
    17-15342-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 3, 2017

    See this permit on One Stop

  24. Permit VCC General Work Permit Cancelled

    To remove all foliage growth from the masonry To remove using hand tools, without expanding the existing joints between bricks, any deteriorated or failing mortar To repoint the masonry utilizing the VCC mortar formula (alternatively a mortar analysis may be submitted to the VCC for approval of a mortar mix designed to exactly imitate the existing mortar) Replace all severally damaged bricks with brick carefully selected to match existing as close as possible in color, size, material, porosity, detail, profile and exposure Reconstruct damaged parapets with brick to match existing All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations but additional violations exist that are not addressed by this permit. Applicant to submit additional information to address other outstanding violation. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.

    Permit
    16-21268-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    169
    Expires
    Jun 15, 2017

    See this permit on One Stop

  25. Permit Renovation (Structural) Permit Cancelled

    Structural repairs to existing bar: repairs include balcony, painting, soffit, windows, masonry and stucco repair, remove balcony extensions, replace spotlights. All work as per plans.

    Permit
    16-21268-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $5,545
    Fees
    $135
    Contractor
    Earth Inc
    Days from application to issue
    174
    Expires
    Jun 19, 2017

    See this permit on One Stop

  26. Permit VCC General Work Permit Cancelled

    To complete work as per plans approved by the Architecture Committee at the 04/28/15 and stamped approved 5/14/15. Work includes repairs to masonry near top of Bourbon elevation, window replacement, and repairs to courtyard balconies, handrails, roofs, and other balcony elements. Courtyard balcony handrails to be constructed according to Hand rail no 1 and details “A” and “H” all found on Standard detail sheet No. 11. All light fixtures to be Remcraft 110. All conduit and wiring shall be placed along the inside corners of building surfaces as much as possible, such as along balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb. NOTE: Work concerning mechanical platform and reconstruction of stairs to be permitted separately once documentation is provided stating mechanical equipment allowed to be installed on neighboring property. Work concerning the Bourbon balcony to be permitted separately once application is received from neighboring property owner to raise balcony guardrail.

    Permit
    14-04084-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  27. Permit VCC General Work Permit Issued

    -To install temporary bracing under balcony on Bourbon per drawing received 02/27/14. -Bracing will be installed on 2/27/14 and will be removed no later than 03/05/14. Note: • Temporary bracing must be installed in a manner that does not damage the existing balconies, galleries, facades, sidewalks, etc., and does not obstruct the sidewalk. •The attachment of temporary supports by welding, bolting, screwing, etc., to the balcony/gallery structure is NOT PERMITTED. • Type of support system must be reviewed, approved, and have permits issued by the Department of Safety and Permits, Department of Public Works, and any other agency with jurisdiction. • The VCC defers all issues of safety, stability, & soundness of the bracing system to the Dept. of Safety & Permits, whose role is to guarantee those intended qualifications.

    Permit
    14-06470-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Aug 27, 2014

    See this permit on One Stop

  28. Permit Renovation (Non-Structural) Permit Issued

    Non-structural repairs to existing bar/souvenir shop. Repairs include replacing ceiling tiles, interior stairs, remove/replace termite infested plywood wall (non-load bearing), replace counter top and base boards.

    Permit
    13-39317-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $4,675
    Fees
    $85
    Contractor
    Earth Inc
    Days from application to issue
    0
    Expires
    Mar 27, 2014

    See this permit on One Stop

  29. Permit Renovation (Non-Structural) Permit Issued

    Non-structural interior repairs. Repairs include new floor.

    Permit
    13-17609-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,800
    Fees
    $70
    Contractor
    Larry King
    Days from application to issue
    0
    Expires
    Dec 6, 2013

    See this permit on One Stop

  30. Permit VCC General Work Permit Finaled

    Erect temporary bracing for 2nd floor balcony or gallery, as per application, engineer's letter, and drawings received on 1/31/13. Temporary bracing will be installed on 2/1/13 and will be removed no later than 2/13/13.

    Permit
    13-03287-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $200
    Fees
    $0
    Days from application to issue
    0
    Expires
    Aug 1, 2013

    See this permit on One Stop

  31. Permit Special Event Permit Issuance Active

    CERTIFICATE OF OCCUPANCY FOR BALCONY BRACING FOR 2012 MARDI GRAS AS PER OWNER'S LETTER,ENGINEER'S, VCCP-12-0114,PUBLIC WORKS MG-2012-057.

    Permit
    12SPE-00123
    Type
    Special Event
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $285
  32. Permit VCC General Work Permit Finaled

    Historical Import Type: Enforcement VCC Permit General User: CABERG Tracking: 86127800901 Status: Permit Issued Status Date: 2/6/2012 12:00:00 AM Owner: 410 Bourbon Street LLC Owner Address: Et Al 994 Topaz St, New Orleans, LA 70124 Owner Phone: 586-9843 Owner Edited By: 2/6/2012 by CABERG Install temporary bracing under balcony/gallery structure, starting Thursday, February 16, 2012 and removed no later than Wednesday, February 22, 2012. • Temporary bracing must be installed in a manner that does not damage the existing balconies, galleries, facades, sidewalks, etc., and does not obstruct the sidewalk. • The attachment of temporary supports by welding, bolting, screwing, etc., to the balcony/gallery structure is not permitted. • Type of support system must be reviewed, approved, and have permits issued by the Department of Safety and Permits, Department of Public Works, and any other agency with jurisdiction. All work must conform to standard VCC policies & guidelines Estimated cost: $400.00 CAB, 02/06/2012

    Permit
    VCCP-12-0114
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  33. Permit Film Master Permit Issuance - Active

    CERTIFICATE OF OCCUPANCY FOR BALCONY BRACING FOR 2011 MARDI GRAS PER OWNER'S LETTER,ENGINEER'S, VCCP-11-0119,PUBLIC WORKS MG-2011-048

    Permit
    11SPE-00121
    Type
    Film Master
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $285
    Days from application to issue
    0
  34. Permit Film Master Application Acceptance - Approved No Review

    Certificate of Occupancy for Mardi Gras bracing as per sketch, dpw permit #2010-052, VCC permit #VCCP-10-0108, and owner's/engineer's letter.

    Permit
    10SPE-00093
    Type
    Film Master
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
    Days from application to issue
    5
  35. Code enforcement Case ENVHADJ-20052701SN Closed

    The property was inspected on 04/11/2005 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 26-20820-SPMA.

  36. Permit Film Master Inspection - None Required

    CERTIFICATE OF OCCUPANCY FOR BRACING FROM JANUARY 23, 2005 THROUGH FEBRUARY 9, 2005 AS PER SKETCH, ENGINEER'S AND OWNER'S LETTER, VCC PERMIT #050039, & DPW PERMIT # MG-2005-544.

    Permit
    05SPE-00082
    Type
    Film Master
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $225
    Days from application to issue
    5
  37. Permit Mechanical Annual Renewal Active
    Permit
    03MCH-06555
    Type
    Mechanical
    Work
    Stationary Equipment Annual
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
  38. Permit Building

    BRACING MIXED OCCUPANCY CERT. OF OCCUPANCY FOR BRACING FROM 02/12/24 THRU 02/25/04 AS PER SKETCH, DPW MG-533, OWNER LTR,VCC #040049, ENG LTR.

    Permit
    B04000672
    Type
    Building
  39. Permit Building

    BRACING MIXED OCCUPANCY CERT. OF OCCUPANCY FOR BRACING FROM 02/12/04 THRU 02/25/04, AS PER SKETCH, ENG. LTR, OWNER LTR, DPW MG-533, AND VCC #040049.

    Permit
    B04000673
    Type
    Building
  40. Permit Building

    BRACING BAR/COCKTAIL CERTIFICATE OF OCCUPANCY FOR BRACING FEBRUARY 20,2003 THRU MARCH 5,03 AS PER ENG.& OWNER'S LETTER,SKETCH,DPW MG-2003- 517 AND VCC #030099.

    Permit
    B03000692
    Type
    Building
  41. Permit Building

    BRACING BAR/COCKTAIL CERTIFICATE OF OCCUPANCY FOR BRACING JANUARY 30TH THRU FEB.15,2002 AS PER OWNER'S & ENG'S LTR'S,SKTCH,MG-2002-02-5 33 AND VCC #020080.B01000939.

    Permit
    B02000429
    Type
    Building
  42. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING INSTALL 2-ELEC WARM AIR FURNACE,4 AND 5-TON A\C SYSTEM. SIDNEY LEE - 467-1400

    Permit
    M01005497
    Type
    Mechanical
    Days from application to issue
    0
  43. Permit Building

    BRACING RETAIL STORE CERTIFICATE OF OCCUMANCY FOR BRACING FOR MARDI GRAS FROM 2-13-01 THRU 2-28-01 PER PUBLIC WORKS' APPROVAL,MG-2001-560, ENGINEER'S LETTER AND VCC #010192.

    Permit
    B01000939
    Type
    Building