French Quarter
601 Bourbon Street is in French Quarter, zoned VCE (French Quarter entertainment area, including bars and live music). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 82 permits on record here; the most recent, a VCC general work permit, was filed in November 2026. 33 are still open. There were 4 past code enforcement cases, the latest in March 2024, all closed. On this block in the past year: 14 requests to 311 and 345 calls to police.
- Zoning
- VCE
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 7,131 sq ft
- Parcel
- 41022433
Everything on record here
86 records, newest first · 33 open
-
Permit VCC General Work In Review
repairs (sound out) stucco per violation 25-34556-VCGEN paint color SW9117 Urban Jungle
- Permit
- 26-27526-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Final VCC
- Application Submitted Complete
- Vieux Carré Commission Pending
-
Permit Renovation (Structural or Non-structural) In Review
repairs (sound out) stucco per violation 25-34556-VCGEN paint color SW9117 Urban Jungle
- Permit
- 26-27526-RENO
- Type
- Renovation (Structural or Non-structural)
- Work
- Renovation (Structural or Non-structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $270
- Contractor
- Constance Restoration
- VCC Review Unpaid
- Building Unpaid
- Building Plan Review Unpaid
- Permit Intake Pending
- Parks and Parkways Tree Review Pending
- Plan Review Pending
- Application Submitted Complete
- Orleans Levee District Pending
- Application submitted
- Zoning Review Complete
- Zoning Complete
- Zoning review
-
Permit VCC Security Camera Application Other
Retain and relocate two Wi-Fi booster devices per materials stamped VCC approved 09/30/2026. Devices to be relocated to be behind the existing lattice screening a minimum of 6”.
- Permit
- 26-27828-VCCAM
- Type
- VCC Security Camera Application
- Work
- VCC Security Camera Application
- Estimated cost (applicant’s figure)
- $500
- Fees
- $0
- Days from application to issue
- 9
- Expires
- Mar 30, 2027
- Final VCC
- Application Submitted Complete
- Application Review Complete
- Permit Approved Complete
- Permit Issued Complete
- Permit Picked Up Complete
- Vieux Carré Commission Complete
-
Permit VCC Paint Application Accepted
repair and paint storefront window per violation 25-34556-VCGEN
- Permit
- 26-27524-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Final VCC
- Application Submitted Complete
- Vieux Carré Commission Pending
-
Permit VCC Paint Application Accepted
abate violations in case 25-34556-VCGEN 1. remove vegetation 2. repair, replace, and paint missing fascia and breaded trim boards of fascia boards paint color SW7005 3.
- Permit
- 26-27523-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Final VCC
- Application Submitted Complete
- Vieux Carré Commission Pending
-
Permit VCC Security Camera Application Permit Cancelled
remove two inactive security cameras per 25-34556-VCGEN install two new cameras on Toulouse elevation.
- Permit
- 26-27522-VCCAM
- Type
- VCC Security Camera Application
- Work
- VCC Security Camera Application
- Estimated cost (applicant’s figure)
- $1,500
- Fees
- $0
- Final VCC
- Application Submitted Complete
- Vieux Carré Commission Pending
-
Permit VCC Security Camera Application Permit Issued
To install new Illumivue dual 8MP IP Camera on the Toulouse elevation per materials stamped VCC approved 10/16/2026. NOTE: Camera has built in red and blue warning lights. Warning lights to be deactivated at all times. Any use of these warning lights voids the approval of this camera.
- Permit
- 26-27521-VCCAM
- Type
- VCC Security Camera Application
- Work
- VCC Security Camera Application
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $0
- Days from application to issue
- 29
- Expires
- Apr 16, 2027
- Final VCC
- Application Submitted Complete
- Materials resubmitted Complete
- Application Review Complete
- Returned for revision Complete
- Vieux Carré Commission Complete
- Materials resubmitted Complete
- Permit Approved Complete
- Permit Issued Complete
-
Permit VCC Sign Other
To install/retain one (1) double-faced aluminum or steel sign to read “Slush Daiquiris Pizza ” per drawings stamped VCC approved 08/13/2026 • Sign will measure: 3’8” w x 3’ h x 1’4” thickness • Sign will hang perpendicular to the street, from existing mast arm • Sign will hang from chains • Top portion of sign will have a white background with multi-colored lettering reading “Slush”. “Slush” letters to be illuminated channel letters with translucent faces. LEDs behind letters to only feature consistent white light at 3000K color temperature and 80+ color rendering index. • Middle portion of sign will have a white background with red neon lettering reading “DAIQUIRIS”. • Bottom portion of sign will have a yellow background with red neon lettering reading “PIZZA”. • No additional illumination or lighting is approved NOTE: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face. Sign must comply with all requirements of the Comprehensive Zoning Ordinance in addition to VCC Guidelines.
- Permit
- 26-18563-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 35
- Expires
- Feb 13, 2027
-
Permit Attached Sign Other
This application is to permit work previously completed. Please note existing double faced sign cabinet remained and ONLY lettering was changed. AFTER THE FACT SIGN PERMIT for 3'-0" x 3'-8" illuminated double faced hanging sign from mast arm
- Permit
- 26-18563-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $1,088
- Contractor
- Buras Signs
- Days from application to issue
- 48
- Expires
- Feb 26, 2027
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Permit Cancelled
CHANGE OF USE TO RETAIL TOBACCO STORE
- Permit
- 26-19843-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
CHANGE OF USE TO RETAIL TOBACCO STORE NO WORK DONE UNDER THIS PERMIT AND NO EXTERIOR CHANGES PERMITTED.
- Permit
- 26-19843-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1
- Fees
- $125
- Days from application to issue
- 29
- Expires
- Feb 4, 2027
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC Paint Other
trim, wndows and doors: SW 700 Pure white, semigloss shutters: SW6216 jasper, semigloss
- Permit
- 26-02263-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Constance Restoration
- Days from application to issue
- 0
- Expires
- Jul 29, 2026
-
Permit VCC Sign Other
To install one (1) double-faced Sintra board sign to read “Big Easy Daiquiris Chicken Pizza Jello Shots” per drawings stamped VCC approved 01/28/2026: • Sign will measure: 30” w x 42” h x 1” thickness • Sign will hang perpendicular to the street from existing mast arm • Sign will hang from chains attached to existing bracket • Sign will have a black background with yellow and red neon lettering • No additional illumination or lighting is approved Note: Sign approved for installation until approved neon sign is ready for installation. This sign to be removed at time of the installation of the neon sign. All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 26-00698-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 19
- Expires
- Jul 28, 2026
-
Permit Attached Sign Other
TEMPORARY SIGN to hang while permanent sign application is being approved. The temporary sign is 24 x 36" same artwork as the sign in the permit. Please see attached. The material is Sintra/Styrene This will be placed in the same position on the building as the permanent sign and will hang from existing mast arm.
- Permit
- 26-00698-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $230
- Contractor
- Buras Signs
- Days from application to issue
- 41
- Expires
- Aug 19, 2026
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC Sign Other
To install one (1) double-faced neon sign to read “Big Easy Daiquiris” per drawings stamped VCC approved 01/16/2026: • Sign will measure: 24” w x 36” h x 18” thickness • Sign will hang perpendicular to the street from existing mast arm • Sign will hang from chains attached to existing bracket • Sign will have a black background with yellow and red neon lettering • Sign will feature clear Lexan vandal cover • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face
- Permit
- 25-38736-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 31
- Expires
- Jul 16, 2026
-
Permit Attached Sign Other
Attached Sign Permit
- Permit
- 25-38736-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $370
- Contractor
- Buras Signs
- Days from application to issue
- 65
- Expires
- Aug 19, 2026
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Other
To remove unpermitted exterior conduit, locating all wiring to the interior of the building, and install four new Remcraft 200 light fixtures in locations above door openings on the Toulouse elevation of the building, per materials stamped VCC approved 03/12/2026. • Fixtures shall be painted or prefinished to match adjacent building surface. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb To install two HikVision turret style cameras on the Toulouse elevation per materials stamped VCC approved 03/12/2026 • Cameras shall be painted or prefinished to match the attached surface • Cameras are to be mounted flush on the building. Conduit boxes and wires should not be visible. • Mounting arms are not allowed. • All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. *NOTE 6/26/26* Camera scope withdrawn from this permit. New application to be submitted for security cmaeras.
- Permit
- 25-34556-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 128
- Expires
- Sep 12, 2026
-
Permit Renovation (Non-Structural) Permit Cancelled
Installation of 4 Remcraft Series 200 Sconces above each first floor door opening on Toulouse St. side. Exposed conduit as previously existed before demolition of wall.
- Permit
- 25-34556-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1,200
- Fees
- $195
- Contractor
- Constance Restoration, LLC
- Application submitted
- Application review
-
Permit VCC Security Camera Application Permit Cancelled
To install two HIKVISION fixed turret cameras on Toulouse elevation per cut sheet submitted 11/04/25 & stamped VCC approved 11/05/25. CAMERAS ARE TO ME SURFACE MOUNTED, NO ARMS OR PROJECTIONS Cameras shall be painted to match the attached surface or prefinished to match the attached service Cameras are to be mounted flush on the building. Conduit boxes and wires should not be visible. Mounting arms are not allowed. All wiring shall be placed in conduits and located as discretely as possible. All conduits to be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line and painted to match the adjacent surfaces. All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. The security camera is not to be attached to the granite or any other location other than the approved location All work must conform to standard VCC policies & guidelines.
- Permit
- 25-34554-VCCAM
- Type
- VCC Security Camera Application
- Work
- VCC Security Camera Application
- Estimated cost (applicant’s figure)
- $600
- Fees
- $0
- Days from application to issue
- 1
- Expires
- May 5, 2026
-
Permit Dumpster/Construction Zone Permit Issued
EMERGENCY PERMIT APPLICATION to shore, remove and replace wall on the Toulouse Street side of the building that is in imminent danger of collapsing. Requesting the sidewalk on Toulouse and Bourbon streets be barricaded and closed to the public until the emergency repairs are complete. The property bearing municipal address 601 Bourbon Street is located at the corner of Bourbon and Toulouse Street. The Department of Safety & Permits Building Permit (25-21237-RNVS) and the Vieux Carre Commission Permit (25-21237-VCGEN) authorizing the performance of the work have already been approved, paid for and issued.
- Permit
- 25-21600-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $315
- Contractor
- Constance Restoration
- Days from application to issue
- 27
- Expires
- Feb 13, 2026
-
Permit VCC General Work Other
To install emergency shoring on the Toulouse and Bourbon St. elevations of the main building as per materials stamped VCC approved 07/16/2025. Reconstruct brick masonry wall on new concrete footing as per attached drawings and engineering letters, approved 9/5/2025. Soft red bricks reviewed and approved on site as part of a larger lot shall be used as per attached approved architectural drawing. VCC staff to be requested for review of brick masonry construction as per discussion on site.
- Permit
- 25-21237-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jan 16, 2026
-
Permit Renovation (Structural) Other
EMERGENCY PERMIT APPLICATION TO SHORE, REMOVE AND REPLACE WALL THAT IS IN IMMINENT DANGER OF COLLAPSING. According to the attached Engineer’s report dated July 14, 2025, the wall on the Toulouse Street side of the building bearing municipal address 601 Bourbon Street “is well outside of sound engineering and construction tolerances and should be replaced immediately” to prevent a collapse of the wall. This permit request includes the shoring of the Toulouse Street and Bourbon Street (partial) sides of the building; erection of a construction wall around the shoring area; removal of approximately 35 feet of the Toulouse Street wall to the parapet; recapping foundation rebar and concrete; rebuilding the wall three wythe thick; and related cosmetic restoration all in accordance with the attached stamped Engineer’s Masonry Wall Shoring and Repair Plans.
- Permit
- 25-21237-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $419,950
- Fees
- $3,870
- Contractor
- Constance Restoration, LLC
- Days from application to issue
- 2
- Expires
- Jan 16, 2026
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit VCC Paint Permit Cancelled
ALL COLORS TO MATCH EXISTING
- Permit
- 24-14342-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- Nov 13, 2024
-
Code enforcement Case 24-01905-MPM Closed
A hearing was held on 12/17/2025 but the result of the hearing is still pending.
- Inspection: Inspection Violation: No WIP
- Violation: 165 Defacement of Property
- Inspection: Inspection No Violation
- Hearing: Initial Hearing Result Pending
The city links this case to permit 26-27526-VCGEN.
-
Permit VCC Paint Other
We would like to paint the front of our business. Currently it is blue and we would like to change it to red.
- Permit
- 24-06338-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC Sign Permit Cancelled
To install one (1) double-faced aluminum and neon sign to read “Booze and Barbecue, Swig and Swine, Bourbon Street New Orleans” per drawings stamped VCC approved 05/24/2023: • Sign will measure: 25” w x 23” h x 12” thickness • Sign will hang perpendicular to the street, centered between the two doors • Sign will hang from new 1.5” square tubing arm, installed below decorative stucco banding • Sign will have a green background with white neon lettering • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 23-09846-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 36
- Expires
- Nov 24, 2023
-
Permit Attached Sign Other
new business double sided neon sign hanging from bracket.
- Permit
- 23-09846-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $128
- Contractor
- OPA Graphics
- Application submitted
-
Permit Electrical Service / Circuit / Feeder Other
install 60AMP disconnect on Verizon small cell pole
- Permit
- 22-21201-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,400
- Fees
- $67
- Contractor
- Brandon Michael Descant
- Application submitted
- Application review
Placed here by its map location from “651 Bourbon St”.
-
Permit VCC Paint Permit Cancelled
To prepare for painting by washing using a low water pressure (400 psi max) and/or sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows in new colors: Walls: Cathedral gray, flat or eggshell Doors, Windows and Trim: Gov Nicholls green, semigloss
- Permit
- 22-10075-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 93
- Expires
- Jan 7, 2023
-
Permit VCC General Work Permit Issued
To retain rooftop mechanical equipment, make repairs to building, and correct violations per Architecture Committee approval of 05/24/2022 and materials stamped VCC approved 06/30/2022. Work includes: • Retention of HVAC units and hood equipment installed on the roof of the courtyard infill • Removal all existing, unpermitted and/or unshielded light fixtures • Installation of new fixtures as per plans. Fixtures shall be painted or prefinished to match adjacent building surface. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb • Repairs to stucco as per VCC standard details (attached) • Removal of all unpermitted satellite dishes, TVs from windows, merchandise, signs, etc. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 22-08975-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 77
- Expires
- Dec 15, 2022
-
Permit Renovation (Non-Structural) Application Accepted
VCC violations per Case #: 21-02805-DBNVCC.See attached compliance plan, architectural drawing and HVAC details.
- Permit
- 22-08975-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $10,000
- Fees
- $705
- Application submitted
-
Permit Electrical Service / Circuit / Feeder Other
Install 70 amp disconnect
- Permit
- 22-01534-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $88
- Contractor
- Timothy Jason Carman
- Application submitted
- Application review
- Permit approved
Placed here by its map location from “651 Bourbon St, NA”.
-
Permit VCC Paint Other
AT&T to place vertical conduit to conceal telecommunications cable at 601-609 Bourbon street per VCC stamped approved photographs dated 07/15/2021. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery purlins at the deck line, and painted to match the adjacent surfaces. Conduit to match building wall colors as follows: 601-03 Bourbon: Sherwin Williams Pirate's Gold, flat or satin finish, and lower seciton of conduit (lower base of building) Bourbon St. Blue or equivalent 605-609: Light blue to match existing (color should match as closely as possible to wall color existing)
- Permit
- 21-18710-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Grady Crawford Construction Co
- Days from application to issue
- 16
- Expires
- Jan 15, 2022
-
Permit Small Cell Installation Other
Multi-Carrier Small Cell Installation – Replace Existing Lamp Post
- Permit
- 21-14584-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $2,500
- Days from application to issue
- 79
- Application submitted
- Application review
- Permit approved
Placed here by its tax bill number from “651 Bourbon St”.
-
Permit VCC Paint Permit Cancelled
Repaint building as follows: walls: cathedral gray, flat or eggshell doors, windows and trim: Gov Nicholls green, semigloss
- Permit
- 20-22066-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Sep 13, 2020
-
Permit VCC Security Camera Application Other
Place Uniti HH at MMP at ROW of Bourbon Street and leave 150' slack. Then trench 6' from the right of way to the side of the building, then rise up 15' in existing conduit and then over 5' to Camera. UF to run 50 foot preterm fiber jumper down the inside of street light pole into 12x12 UF HH set in front of street light. UF to splice fiber jumper coming from small HH to tie cable from MMHH that OSP will set. Construction 1-2 days/12 ct. UF will notify property at least 24 hours prior to construction. Ground conditions will be restored to existing or better conditions.
- Permit
- 19-13470-VCCAM
- Type
- VCC Security Camera Application
- Work
- VCC Security Camera Application
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $0
- Contractor
- Southern Light LLC
-
Permit VCC General Work Permit Cancelled
To renovate the Bourbon St. elevation of the 605-609 Bourbon St. building as per Architecture Committee approval of 05/14/19 and materials stamped VCC approved 06/21/19. Work includes: • Replacement of existing ten (10) lite French doors with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Replacement of existing two (2) lite French doors at 605 Bourbon with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Removal of all existing, unpermitted and/or unshielded light fixtures • Installation of two (2) Konial 5” outdoor wall sconces to the wall above the door openings at 605 and 609 Bourbon • Fixtures shall be painted or prefinished to match adjacent building surface. • All wiring shall be placed in conduits • All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, or exposures as specified in permit will result in a VCC violation and mandated repair of improper work.
- Permit
- 19-08359-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 84
- Expires
- Dec 24, 2019
-
Permit VCC General Work Permit Cancelled
The installation of new vent hood that will require an exhaust vent that will penetrate the roof and a fresh air intake vent on the side wall as shown on plan and the addition of a 8'x8' wood deck on the roof and cooling equipment.
- Permit
- 19-08363-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
The installation of new vent hood that will require an exhaust vent that will penetrate the roof and a fresh air intake vent on the side wall as shown on plan and the addition of a 8'x8' wood deck on the roof and cooling equipment.
- Permit
- 19-08363-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $22,000
- Fees
- $345
- Contractor
- Constance Restoration LLC
- Application submitted
-
Permit Renovation (Non-Structural) Permit Cancelled
The replacement of a bay window and a set of French doors with 2 new sets of French doors that match existing doors in the same building.
- Permit
- 19-08359-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $7,200
- Fees
- $240
- Contractor
- Constance Restoration LLC
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
-
Permit Electrical Sign Permit Issued
Connect sign to existing electrical feed. 27143
- Permit
- 19-09778-ESGN
- Type
- Electrical Sign
- Work
- Electrical Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Casper Phillip Gelbke III
- Days from application to issue
- 0
- Expires
- Sep 27, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Cancelled
Proposal to install new hood vent, per application received 03/12/19.
- Permit
- 19-07646-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Eric Percle
-
Permit Hoods Permit Issued
Install a 1 ft roof. 37675
- Permit
- 19-07646-HOOD
- Type
- Hoods
- Work
- Hoods
- Estimated cost (applicant’s figure)
- $0
- Fees
- $50
- Contractor
- Eric Percle
- Days from application to issue
- 0
- Expires
- Sep 12, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Electrical Repair / Replacement / Addition Permit Issued
Renovations to interior
- Permit
- 19-00739-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $8,000
- Fees
- $412
- Contractor
- Stephen Michael Guillot
- Days from application to issue
- 1
- Expires
- Jul 9, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit VCC Sign Permit Finaled
• To install one (1) double-faced aluminum or steel sign to read “Slush Frozen Cocktails Epic Fires ” per drawings stamped VCC approved 01/28/19 • Sign will measure: 3’8” w x 3’ h x 1’10” thickness • Sign will hang perpendicular to the street, from existing mast arm • Sign will hang from chains • Top portion of sign will have a white background with multi-colored lettering reading “Slush”. “Slush” letters to be illuminated channel letters with translucent faces. LEDs behind letters to only feature consistent white light at 3000K color temperature and 80+ color rendering index. Top portion of sign will also feature blue vinyl lettering reading “Frozen Cocktails”. • Bottom portion of sign will have a yellow background with horizontal yellow colored neon lines. Bottom portion will feature red neon lettering reading “Epic Fries”. • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.
- Permit
- 18-41442-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 47
- Expires
- Aug 5, 2019
-
Permit Attached Sign Permit Issued
Install new sign for business
- Permit
- 18-41442-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $345
- Contractor
- A-1 Signs Inc
- Days from application to issue
- 49
- Expires
- Aug 6, 2019
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Mechanical HVAC Permit Finaled
(2) 15 Ton Air Conditioning Systems with 20 kw heat
- Permit
- 18-40122-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $14,000
- Fees
- $191
- Days from application to issue
- 0
- Expires
- Jun 7, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Street Cut Other
Install fiber optic cable for Creole Cuisine
- Permit
- 18-29603-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 815
- Expires
- May 30, 2021
-
Permit VCC Sign Permit Cancelled
To retain as the single business sign for 607 Bourbon hanging on existing bracket. "Huge Ass Beers" sign 25" x 30"
- Permit
- 18-28490-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Permit Cancelled
VCC application to retain awning installed on Dauphine side of building without a permit.
- Permit
- 18-28486-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Interior repair work only including painting the entire interior, installation of new floors, installation of new bar counter top and new tile floors in the restrooms.
- Permit
- 18-29098-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $73,000
- Fees
- $425
- Days from application to issue
- 0
- Expires
- Feb 28, 2019
- Application submitted
- Application review
- Zoning review
- Permit approved
- Issue date
- First inspection
-
Permit Attached Sign Other
To retain as the single business sign for 607 Bourbon hanging on existing bracket. "Huge Ass Beers" sign 25" x 30"
- Permit
- 18-28490-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $285
- Application submitted
-
Permit Renovation (Non-Structural) Other
VCC application to retain awning installed on Dauphine side of building without a permit.
- Permit
- 18-28486-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $90
- Application submitted
-
Permit Renovation (Non-Structural) Other
Place Uniti HH at MMP at ROW of Toulouse Street and leave 150' slack. Trench 5' from the right of way to the side of the building, then rise up 10' in existing conduit and penetrate into closed courtyard area. Pull fiber along inside wall 75' in EMT, penetrate into the 2nd Floor. Pull another 25' to 2nd Floor Telco Closet Backboard and leave 50' slack. Construction 2-3 days/12 ct. MPO - Customer to install Space & Power. UF contractor will need to pull an additional pull string through existing conduit. UF will notify property at least 24 hours prior to construction. Ground conditions will be restored to existing or better conditions.
- Permit
- 18-27347-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $85
- Contractor
- Southern Light LLC
- Days from application to issue
- 93
- Expires
- May 20, 2019
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Cancelled
To renovate building and correct violations as per materials stamped VCC approved 08/28/18. Work includes: • Repairing/replacing deteriorated woodwork to exactly match existing including storefront windows, doors, vitrines, and balcony fascia • Repairing/replacing gutter and downspout on the Bourbon elevation of the 811 Toulouse building • Removing all unused wires from the building’s exterior • Removing all unpermitted signage • Painting all repaired/replaced woodwork to match existing color…white, semigloss All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 18-25433-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 26
- Expires
- Feb 28, 2019
-
Permit Renovation (Non-Structural) Permit Cancelled
Repairs in response to VCC Case No.: 18-4991-DBNVCC for the following municipal addresses: 601, 605, 609 Bourbon Street and 811 Toulouse Street. The purpose of this permit is to remedy and include the following: 1. 166-121. Windows. Repair storefront window. 2. 166-121. Doors. Repair doors on Bourbon Street. 3. 166-121. Balconies. Repair deterioration on 811 Toulouse building. 4. 166-121. Paint. Repair paint deterioration. 5. 166-121. Gutters. Repair gutter and downspout on Bourbon street. 6. 166-35. Awnings. Installation of awning on second story of Dauphine elevation at 811 Toulouse. 7. 166-35. Lighting. Replace exterior light fixtures with shielded fixtures on 605 and 609 Bourbon street. 8. 166-35. Windows. Remove plywood installed in window. 9. 166-35. Wires. Remove unused wires and paint necessary cables to match building. 10. 166-80. Permit required for signs. Need to apply for sign permit, if one is not already applied and approved. 11. 166-77. General Prohibition of Misc. Signs. Impermissible exit sign. 12. 166-84. Signs shall not be placed on fence. Regarding the aforementioned exit sign. 13. 166-125. Merchandising of certain items. Hanging merchandise on the doors and shutters. All to be removed.
- Permit
- 18-25433-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $7,500
- Fees
- $150
- Application submitted
- Application review
- Zoning review
- Plan review
-
Permit VCC Paint Permit Cancelled
Utility (Entergy Gas) work required to convert customer onto new High Pressure gas lines being installed with City Reconstruction Project. A gas service line will be installed from sidewalk base and elbow into building for gas supply. An iron curb valve access port will be installed at sidewalk surface with below grade valve for emergency service isolation. Per application and materials recieved 4/10/18 adn stamped VCC approved 4/12/18. The new line will be painted to match the adjacent surface.
- Permit
- 18-12040-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- Oct 12, 2018
-
Permit VCC Paint Permit Cancelled
Utility (Entergy Gas) work required to convert customer onto new High Pressure gas lines being installed with City Reconstruction Project. A gas service line will be installed from sidewalk base and elbow into building for gas supply. An iron curb valve access port will be installed at sidewalk surface with below grade valve for emergency service isolation. Per application and materials recieved 4/10/18 and stamped VCC approved 4/12/18. The new line will be painted to match the adjacent surface.
- Permit
- 18-12039-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- Oct 12, 2018
-
Permit VCC Paint Permit Finaled
• Walls...Pirates Gold, flat or satin finish • Wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery...white, semigloss • Shutters…Barracks Grey, semigloss
- Permit
- 14-24465-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 5, 2015
-
Permit VCC General Work Permit Issued
Remove seven (7) existing pairs of floodlights on facade of building; Replace with six (6) pairs of shielded floodlights, using "Affordable Lamps" fixtures shown in drawing received with application 6/10/13 and stamped VCC approved on 6/12/13. Two sets of floodlights to go over doorway, two over vitrine/display window, and two at edge of roof. Remove metal alarm box over doorway. Repaint dormers and trim: color to be white. Replace missing slate in kind on sides of dormers. Remove vegetation from brick masonry, and re-mortar/stucco where necessary, using appropriate soft lime mortar mix (see formula below.) Repair rotten/missing wood trim on vitrine/display window to match existing, and repaint: color to be white.
- Permit
- 13-18220-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $1,789
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Dec 12, 2013
-
Permit Electrical Service / Circuit / Feeder Permit Issued
Work Descripton: ADD CIRCUITS- 11COM-00985 Historical Import Type: Permits Electrical Commercial Service-Circuits-Feeders User: DMFOLEY Tracking: 86156848137 Status: Permit Issuance Active Status Date: 4/26/2012 12:00:00 AM Owner: Mintz Willie Owner Address: 5529 Magazine St, New Orleans, LA 70115 Owner Edited By: 4/26/2012 by DMFOLEY
- Permit
- 12ELC-04685
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $52
- Contractor
- Pelican Elect Contr
- Days from application to issue
- 0
- Expires
- Oct 26, 2012
-
Permit General Mechanical Inspection Phase
Work Descripton: new gasline;2-deepfryers/1-griddle/david /ck#11162. Historical Import Type: Permits Mechanical Residential General Mechanical User: RHARDOUIN Tracking: 186176556162 Status: Meter Released Status Date: 12/21/2011 12:00:00 AM Owner: Mintz Willie Owner Address: 5529 Magazine St, New Orleans, LA 70115 Owner Edited By: 12/16/2011 by RHARDOUIN
- Permit
- 11MCH-10128
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $75
- Contractor
- David Carter's Plbg LLC
- Expires
- Jun 21, 2012
-
Permit Mechanical Closed
INSTALL KITCHEN HOOD. JOHN WOOD (#1587)
- Permit
- 11MCH-10099
- Type
- Mechanical
- Work
- Hoods
- Estimated cost (applicant’s figure)
- $0
- Fees
- $50
-
Permit Electrical Permit Issuance Active
UPGRADE- 11COM-00985
- Permit
- 11ELC-12441
- Type
- Electrical
- Work
- Service-Circuits-Feeders
- Estimated cost (applicant’s figure)
- $0
- Fees
- $49
-
Permit Commercial Permit Issuance Active
REMOVE/REPLACE OLD KITCHEN HOOD SYSTEM ALONG WITH NEW FIRE SYSTEM AS PER SKETCH AND STATE FIRE MARSHALL APPROVAL. NO EXTERIOR WORK ALLOWED UNDER THIS PERMIT.
- Permit
- 11COM-01560
- Type
- Commercial
- Work
- NA
- Estimated cost (applicant’s figure)
- $10,000
- Fees
- $110
-
Permit Commercial Permit Issuance Active
INTERIOR RENOVATIONS IN THE KITCHEN AREA, NEW EQUIPMENT,NEW FRYERS,GRILL;HOOD AND SINKS.
- Permit
- 11COM-00985
- Type
- Commercial
- Work
- NA
- Estimated cost (applicant’s figure)
- $35,000
- Fees
- $235
-
Code enforcement Case ENVHADJ-994171F Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 26-27524-VCPNT.
-
Code enforcement Case ENVHADJ-20001819F Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 26-27524-VCPNT.
-
Code enforcement Case ENVHADJ-2000355F Closed
The property was inspected on 12/03/1999 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 26-27524-VCPNT.
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-06679
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2004 PAID FOR 1
- Permit
- S04000660
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1
- Permit
- S04000071
- Type
- Sign
- Days from application to issue
- 0
-
Permit Electrical
ELECTRICAL VACANCY REPAIRS RETAIL STORE FRED VANLANGENDONCK
- Permit
- E03007229
- Type
- Electrical
- Days from application to issue
- 0
Placed here by the building address from “811 TOULOUSE ST UNIT D”.
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2003 PAID FOR 1
- Permit
- S03000748
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2003
- Permit
- S03000048
- Type
- Sign
- Days from application to issue
- 0
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT RESTAURANT 49 AND UNDER INSTALLATION OF 6 TON A/C UNIT. RONALD 469-3760.
- Permit
- M02004929
- Type
- Mechanical
- Days from application to issue
- 3
-
Permit Building
RE-ROOF (COMMERCIAL) MIXED OCCUPANCY ROOF REPLACEMENT AS PER VCC # 020282
- Permit
- B02003340
- Type
- Building
-
Permit Building
RE-ROOF (COMMERCIAL) MIXED OCCUPANCY REROOF EXISTING MIXED USE BUILDING PER VCC #020282
- Permit
- B02003341
- Type
- Building
-
Permit Building
RE-ROOF (COMMERCIAL) MIXED OCCUPANCY REROOF EXISTING MIXED USE BUILDING PER VCC # 020282
- Permit
- B02003343
- Type
- Building
- Days from application to issue
- 8
-
Permit Building
RE-ROOF (COMMERCIAL) BAR/COCKTAIL REROOF EXISTING BAR AS PER VCC 020281
- Permit
- B02003344
- Type
- Building
- Days from application to issue
- 8
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEES 2002 PAID
- Permit
- S02000153
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEES 2002 PAID
- Permit
- S02000129
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2001 PAID
- Permit
- S01000485
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000080
- Type
- Sign
- Days from application to issue
- 0
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING
- Permit
- M99003597
- Type
- Mechanical
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN OPERATING FEE FOR 1998
- Permit
- S98000545
- Type
- Sign