French Quarter

601 Bourbon Street is in French Quarter, zoned VCE (French Quarter entertainment area, including bars and live music). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 82 permits on record here; the most recent, a VCC general work permit, was filed in November 2026. 33 are still open. There were 4 past code enforcement cases, the latest in March 2024, all closed. On this block in the past year: 14 requests to 311 and 345 calls to police.

Zoning
VCE
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
7,131 sq ft
Parcel
41022433

Everything on record here

86 records, newest first · 33 open

  1. Permit VCC General Work In Review

    repairs (sound out) stucco per violation 25-34556-VCGEN paint color SW9117 Urban Jungle

    Permit
    26-27526-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    1. Final VCC
    2. Application Submitted Complete
    3. Vieux Carré Commission Pending

    See this permit on One Stop

  2. Permit Renovation (Structural or Non-structural) In Review

    repairs (sound out) stucco per violation 25-34556-VCGEN paint color SW9117 Urban Jungle

    Permit
    26-27526-RENO
    Type
    Renovation (Structural or Non-structural)
    Work
    Renovation (Structural or Non-structural)
    Estimated cost (applicant’s figure)
    $0
    Fees
    $270
    Contractor
    Constance Restoration
    1. VCC Review Unpaid
    2. Building Unpaid
    3. Building Plan Review Unpaid
    4. Permit Intake Pending
    5. Parks and Parkways Tree Review Pending
    6. Plan Review Pending
    7. Application Submitted Complete
    8. Orleans Levee District Pending
    9. Application submitted
    10. Zoning Review Complete
    11. Zoning Complete
    12. Zoning review

    See this permit on One Stop

  3. Permit VCC Security Camera Application Other

    Retain and relocate two Wi-Fi booster devices per materials stamped VCC approved 09/30/2026. Devices to be relocated to be behind the existing lattice screening a minimum of 6”.

    Permit
    26-27828-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $500
    Fees
    $0
    Days from application to issue
    9
    Expires
    Mar 30, 2027
    1. Final VCC
    2. Application Submitted Complete
    3. Application Review Complete
    4. Permit Approved Complete
    5. Permit Issued Complete
    6. Permit Picked Up Complete
    7. Vieux Carré Commission Complete

    See this permit on One Stop

  4. Permit VCC Paint Application Accepted

    repair and paint storefront window per violation 25-34556-VCGEN

    Permit
    26-27524-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    1. Final VCC
    2. Application Submitted Complete
    3. Vieux Carré Commission Pending

    See this permit on One Stop

  5. Permit VCC Paint Application Accepted

    abate violations in case 25-34556-VCGEN 1. remove vegetation 2. repair, replace, and paint missing fascia and breaded trim boards of fascia boards paint color SW7005 3.

    Permit
    26-27523-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    1. Final VCC
    2. Application Submitted Complete
    3. Vieux Carré Commission Pending

    See this permit on One Stop

  6. Permit VCC Security Camera Application Permit Cancelled

    remove two inactive security cameras per 25-34556-VCGEN install two new cameras on Toulouse elevation.

    Permit
    26-27522-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $1,500
    Fees
    $0
    1. Final VCC
    2. Application Submitted Complete
    3. Vieux Carré Commission Pending

    See this permit on One Stop

  7. Permit VCC Security Camera Application Permit Issued

    To install new Illumivue dual 8MP IP Camera on the Toulouse elevation per materials stamped VCC approved 10/16/2026. NOTE: Camera has built in red and blue warning lights. Warning lights to be deactivated at all times. Any use of these warning lights voids the approval of this camera.

    Permit
    26-27521-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $2,500
    Fees
    $0
    Days from application to issue
    29
    Expires
    Apr 16, 2027
    1. Final VCC
    2. Application Submitted Complete
    3. Materials resubmitted Complete
    4. Application Review Complete
    5. Returned for revision Complete
    6. Vieux Carré Commission Complete
    7. Materials resubmitted Complete
    8. Permit Approved Complete
    9. Permit Issued Complete

    See this permit on One Stop

  8. Permit VCC Sign Other

    To install/retain one (1) double-faced aluminum or steel sign to read “Slush Daiquiris Pizza ” per drawings stamped VCC approved 08/13/2026 • Sign will measure: 3’8” w x 3’ h x 1’4” thickness • Sign will hang perpendicular to the street, from existing mast arm • Sign will hang from chains • Top portion of sign will have a white background with multi-colored lettering reading “Slush”. “Slush” letters to be illuminated channel letters with translucent faces. LEDs behind letters to only feature consistent white light at 3000K color temperature and 80+ color rendering index. • Middle portion of sign will have a white background with red neon lettering reading “DAIQUIRIS”. • Bottom portion of sign will have a yellow background with red neon lettering reading “PIZZA”. • No additional illumination or lighting is approved NOTE: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face. Sign must comply with all requirements of the Comprehensive Zoning Ordinance in addition to VCC Guidelines.

    Permit
    26-18563-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    35
    Expires
    Feb 13, 2027

    See this permit on One Stop

  9. Permit Attached Sign Other

    This application is to permit work previously completed. Please note existing double faced sign cabinet remained and ONLY lettering was changed. AFTER THE FACT SIGN PERMIT for 3'-0" x 3'-8" illuminated double faced hanging sign from mast arm

    Permit
    26-18563-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $1,088
    Contractor
    Buras Signs
    Days from application to issue
    48
    Expires
    Feb 26, 2027
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  10. Permit VCC General Work Permit Cancelled

    CHANGE OF USE TO RETAIL TOBACCO STORE

    Permit
    26-19843-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  11. Permit Renovation (Non-Structural) Other

    CHANGE OF USE TO RETAIL TOBACCO STORE NO WORK DONE UNDER THIS PERMIT AND NO EXTERIOR CHANGES PERMITTED.

    Permit
    26-19843-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1
    Fees
    $125
    Days from application to issue
    29
    Expires
    Feb 4, 2027
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  12. Permit VCC Paint Other

    trim, wndows and doors: SW 700 Pure white, semigloss shutters: SW6216 jasper, semigloss

    Permit
    26-02263-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Constance Restoration
    Days from application to issue
    0
    Expires
    Jul 29, 2026

    See this permit on One Stop

  13. Permit VCC Sign Other

    To install one (1) double-faced Sintra board sign to read “Big Easy Daiquiris Chicken Pizza Jello Shots” per drawings stamped VCC approved 01/28/2026: • Sign will measure: 30” w x 42” h x 1” thickness • Sign will hang perpendicular to the street from existing mast arm • Sign will hang from chains attached to existing bracket • Sign will have a black background with yellow and red neon lettering • No additional illumination or lighting is approved Note: Sign approved for installation until approved neon sign is ready for installation. This sign to be removed at time of the installation of the neon sign. All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.

    Permit
    26-00698-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    19
    Expires
    Jul 28, 2026

    See this permit on One Stop

  14. Permit Attached Sign Other

    TEMPORARY SIGN to hang while permanent sign application is being approved. The temporary sign is 24 x 36" same artwork as the sign in the permit. Please see attached. The material is Sintra/Styrene This will be placed in the same position on the building as the permanent sign and will hang from existing mast arm.

    Permit
    26-00698-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $230
    Contractor
    Buras Signs
    Days from application to issue
    41
    Expires
    Aug 19, 2026
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  15. Permit VCC Sign Other

    To install one (1) double-faced neon sign to read “Big Easy Daiquiris” per drawings stamped VCC approved 01/16/2026: • Sign will measure: 24” w x 36” h x 18” thickness • Sign will hang perpendicular to the street from existing mast arm • Sign will hang from chains attached to existing bracket • Sign will have a black background with yellow and red neon lettering • Sign will feature clear Lexan vandal cover • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 8’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face

    Permit
    25-38736-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    31
    Expires
    Jul 16, 2026

    See this permit on One Stop

  16. Permit Attached Sign Other

    Attached Sign Permit

    Permit
    25-38736-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $370
    Contractor
    Buras Signs
    Days from application to issue
    65
    Expires
    Aug 19, 2026
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  17. Permit VCC General Work Other

    To remove unpermitted exterior conduit, locating all wiring to the interior of the building, and install four new Remcraft 200 light fixtures in locations above door openings on the Toulouse elevation of the building, per materials stamped VCC approved 03/12/2026. • Fixtures shall be painted or prefinished to match adjacent building surface. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb To install two HikVision turret style cameras on the Toulouse elevation per materials stamped VCC approved 03/12/2026 • Cameras shall be painted or prefinished to match the attached surface • Cameras are to be mounted flush on the building. Conduit boxes and wires should not be visible. • Mounting arms are not allowed. • All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. *NOTE 6/26/26* Camera scope withdrawn from this permit. New application to be submitted for security cmaeras.

    Permit
    25-34556-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    128
    Expires
    Sep 12, 2026

    See this permit on One Stop

  18. Permit Renovation (Non-Structural) Permit Cancelled

    Installation of 4 Remcraft Series 200 Sconces above each first floor door opening on Toulouse St. side. Exposed conduit as previously existed before demolition of wall.

    Permit
    25-34556-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,200
    Fees
    $195
    Contractor
    Constance Restoration, LLC
    1. Application submitted
    2. Application review

    See this permit on One Stop

  19. Permit VCC Security Camera Application Permit Cancelled

    To install two HIKVISION fixed turret cameras on Toulouse elevation per cut sheet submitted 11/04/25 & stamped VCC approved 11/05/25. CAMERAS ARE TO ME SURFACE MOUNTED, NO ARMS OR PROJECTIONS Cameras shall be painted to match the attached surface or prefinished to match the attached service Cameras are to be mounted flush on the building. Conduit boxes and wires should not be visible. Mounting arms are not allowed. All wiring shall be placed in conduits and located as discretely as possible. All conduits to be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line and painted to match the adjacent surfaces. All cameras to be installed a minimum of 9-feet above the sidewalk and a maximum of 18-inches below the bottom of the balcony, gallery, porch ceiling, roof overhang, or soffit. The security camera is not to be attached to the granite or any other location other than the approved location All work must conform to standard VCC policies & guidelines.

    Permit
    25-34554-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $600
    Fees
    $0
    Days from application to issue
    1
    Expires
    May 5, 2026

    See this permit on One Stop

  20. Permit Dumpster/Construction Zone Permit Issued

    EMERGENCY PERMIT APPLICATION to shore, remove and replace wall on the Toulouse Street side of the building that is in imminent danger of collapsing. Requesting the sidewalk on Toulouse and Bourbon streets be barricaded and closed to the public until the emergency repairs are complete. The property bearing municipal address 601 Bourbon Street is located at the corner of Bourbon and Toulouse Street. The Department of Safety & Permits Building Permit (25-21237-RNVS) and the Vieux Carre Commission Permit (25-21237-VCGEN) authorizing the performance of the work have already been approved, paid for and issued.

    Permit
    25-21600-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $315
    Contractor
    Constance Restoration
    Days from application to issue
    27
    Expires
    Feb 13, 2026

    See this permit on One Stop

  21. Permit VCC General Work Other

    To install emergency shoring on the Toulouse and Bourbon St. elevations of the main building as per materials stamped VCC approved 07/16/2025. Reconstruct brick masonry wall on new concrete footing as per attached drawings and engineering letters, approved 9/5/2025. Soft red bricks reviewed and approved on site as part of a larger lot shall be used as per attached approved architectural drawing. VCC staff to be requested for review of brick masonry construction as per discussion on site.

    Permit
    25-21237-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Jan 16, 2026

    See this permit on One Stop

  22. Permit Renovation (Structural) Other

    EMERGENCY PERMIT APPLICATION TO SHORE, REMOVE AND REPLACE WALL THAT IS IN IMMINENT DANGER OF COLLAPSING. According to the attached Engineer’s report dated July 14, 2025, the wall on the Toulouse Street side of the building bearing municipal address 601 Bourbon Street “is well outside of sound engineering and construction tolerances and should be replaced immediately” to prevent a collapse of the wall. This permit request includes the shoring of the Toulouse Street and Bourbon Street (partial) sides of the building; erection of a construction wall around the shoring area; removal of approximately 35 feet of the Toulouse Street wall to the parapet; recapping foundation rebar and concrete; rebuilding the wall three wythe thick; and related cosmetic restoration all in accordance with the attached stamped Engineer’s Masonry Wall Shoring and Repair Plans.

    Permit
    25-21237-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $419,950
    Fees
    $3,870
    Contractor
    Constance Restoration, LLC
    Days from application to issue
    2
    Expires
    Jan 16, 2026
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  23. Permit VCC Paint Permit Cancelled

    ALL COLORS TO MATCH EXISTING

    Permit
    24-14342-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    Nov 13, 2024

    See this permit on One Stop

  24. Code enforcement Case 24-01905-MPM Closed

    A hearing was held on 12/17/2025 but the result of the hearing is still pending.

    1. Inspection: Inspection Violation: No WIP
    2. Violation: 165 Defacement of Property
    3. Inspection: Inspection No Violation
    4. Hearing: Initial Hearing Result Pending

    The city links this case to permit 26-27526-VCGEN.

  25. Permit VCC Paint Other

    We would like to paint the front of our business. Currently it is blue and we would like to change it to red.

    Permit
    24-06338-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  26. Permit VCC Sign Permit Cancelled

    To install one (1) double-faced aluminum and neon sign to read “Booze and Barbecue, Swig and Swine, Bourbon Street New Orleans” per drawings stamped VCC approved 05/24/2023: • Sign will measure: 25” w x 23” h x 12” thickness • Sign will hang perpendicular to the street, centered between the two doors • Sign will hang from new 1.5” square tubing arm, installed below decorative stucco banding • Sign will have a green background with white neon lettering • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.

    Permit
    23-09846-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    36
    Expires
    Nov 24, 2023

    See this permit on One Stop

  27. Permit Attached Sign Other

    new business double sided neon sign hanging from bracket.

    Permit
    23-09846-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $128
    Contractor
    OPA Graphics
    1. Application submitted

    See this permit on One Stop

  28. Permit Electrical Service / Circuit / Feeder Other

    install 60AMP disconnect on Verizon small cell pole

    Permit
    22-21201-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $2,400
    Fees
    $67
    Contractor
    Brandon Michael Descant
    1. Application submitted
    2. Application review

    See this permit on One Stop

    Placed here by its map location from “651 Bourbon St”.

  29. Permit VCC Paint Permit Cancelled

    To prepare for painting by washing using a low water pressure (400 psi max) and/or sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows in new colors: Walls: Cathedral gray, flat or eggshell Doors, Windows and Trim: Gov Nicholls green, semigloss

    Permit
    22-10075-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    93
    Expires
    Jan 7, 2023

    See this permit on One Stop

  30. Permit VCC General Work Permit Issued

    To retain rooftop mechanical equipment, make repairs to building, and correct violations per Architecture Committee approval of 05/24/2022 and materials stamped VCC approved 06/30/2022. Work includes: • Retention of HVAC units and hood equipment installed on the roof of the courtyard infill • Removal all existing, unpermitted and/or unshielded light fixtures • Installation of new fixtures as per plans. Fixtures shall be painted or prefinished to match adjacent building surface. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb • Repairs to stucco as per VCC standard details (attached) • Removal of all unpermitted satellite dishes, TVs from windows, merchandise, signs, etc. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.

    Permit
    22-08975-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    77
    Expires
    Dec 15, 2022

    See this permit on One Stop

  31. Permit Renovation (Non-Structural) Application Accepted

    VCC violations per Case #: 21-02805-DBNVCC.See attached compliance plan, architectural drawing and HVAC details.

    Permit
    22-08975-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $10,000
    Fees
    $705
    1. Application submitted

    See this permit on One Stop

  32. Permit Electrical Service / Circuit / Feeder Other

    Install 70 amp disconnect

    Permit
    22-01534-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $2,500
    Fees
    $88
    Contractor
    Timothy Jason Carman
    1. Application submitted
    2. Application review
    3. Permit approved

    See this permit on One Stop

    Placed here by its map location from “651 Bourbon St, NA”.

  33. Permit VCC Paint Other

    AT&T to place vertical conduit to conceal telecommunications cable at 601-609 Bourbon street per VCC stamped approved photographs dated 07/15/2021. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery purlins at the deck line, and painted to match the adjacent surfaces. Conduit to match building wall colors as follows: 601-03 Bourbon: Sherwin Williams Pirate's Gold, flat or satin finish, and lower seciton of conduit (lower base of building) Bourbon St. Blue or equivalent 605-609: Light blue to match existing (color should match as closely as possible to wall color existing)

    Permit
    21-18710-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Grady Crawford Construction Co
    Days from application to issue
    16
    Expires
    Jan 15, 2022

    See this permit on One Stop

  34. Permit Small Cell Installation Other

    Multi-Carrier Small Cell Installation – Replace Existing Lamp Post

    Permit
    21-14584-SMCL
    Type
    Small Cell Installation
    Work
    Small Cell Installation
    Estimated cost (applicant’s figure)
    $0
    Fees
    $2,500
    Days from application to issue
    79
    1. Application submitted
    2. Application review
    3. Permit approved

    See this permit on One Stop

    Placed here by its tax bill number from “651 Bourbon St”.

  35. Permit VCC Paint Permit Cancelled

    Repaint building as follows: walls: cathedral gray, flat or eggshell doors, windows and trim: Gov Nicholls green, semigloss

    Permit
    20-22066-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Sep 13, 2020

    See this permit on One Stop

  36. Permit VCC Security Camera Application Other

    Place Uniti HH at MMP at ROW of Bourbon Street and leave 150' slack. Then trench 6' from the right of way to the side of the building, then rise up 15' in existing conduit and then over 5' to Camera. UF to run 50 foot preterm fiber jumper down the inside of street light pole into 12x12 UF HH set in front of street light. UF to splice fiber jumper coming from small HH to tie cable from MMHH that OSP will set. Construction 1-2 days/12 ct. UF will notify property at least 24 hours prior to construction. Ground conditions will be restored to existing or better conditions.

    Permit
    19-13470-VCCAM
    Type
    VCC Security Camera Application
    Work
    VCC Security Camera Application
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $0
    Contractor
    Southern Light LLC

    See this permit on One Stop

  37. Permit VCC General Work Permit Cancelled

    To renovate the Bourbon St. elevation of the 605-609 Bourbon St. building as per Architecture Committee approval of 05/14/19 and materials stamped VCC approved 06/21/19. Work includes: • Replacement of existing ten (10) lite French doors with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Replacement of existing two (2) lite French doors at 605 Bourbon with new eight (8) lite, wood, true divided lite French doors to exactly match existing French doors at 601-603 Bourbon • Removal of all existing, unpermitted and/or unshielded light fixtures • Installation of two (2) Konial 5” outdoor wall sconces to the wall above the door openings at 605 and 609 Bourbon • Fixtures shall be painted or prefinished to match adjacent building surface. • All wiring shall be placed in conduits • All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, or exposures as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    19-08359-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    84
    Expires
    Dec 24, 2019

    See this permit on One Stop

  38. Permit VCC General Work Permit Cancelled

    The installation of new vent hood that will require an exhaust vent that will penetrate the roof and a fresh air intake vent on the side wall as shown on plan and the addition of a 8'x8' wood deck on the roof and cooling equipment.

    Permit
    19-08363-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  39. Permit Renovation (Non-Structural) Other

    The installation of new vent hood that will require an exhaust vent that will penetrate the roof and a fresh air intake vent on the side wall as shown on plan and the addition of a 8'x8' wood deck on the roof and cooling equipment.

    Permit
    19-08363-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $22,000
    Fees
    $345
    Contractor
    Constance Restoration LLC
    1. Application submitted

    See this permit on One Stop

  40. Permit Renovation (Non-Structural) Permit Cancelled

    The replacement of a bay window and a set of French doors with 2 new sets of French doors that match existing doors in the same building.

    Permit
    19-08359-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,200
    Fees
    $240
    Contractor
    Constance Restoration LLC
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved

    See this permit on One Stop

  41. Permit Electrical Sign Permit Issued

    Connect sign to existing electrical feed. 27143

    Permit
    19-09778-ESGN
    Type
    Electrical Sign
    Work
    Electrical Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40
    Contractor
    Casper Phillip Gelbke III
    Days from application to issue
    0
    Expires
    Sep 27, 2019
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

  42. Permit VCC General Work Permit Cancelled

    Proposal to install new hood vent, per application received 03/12/19.

    Permit
    19-07646-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Eric Percle

    See this permit on One Stop

  43. Permit Hoods Permit Issued

    Install a 1 ft roof. 37675

    Permit
    19-07646-HOOD
    Type
    Hoods
    Work
    Hoods
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
    Contractor
    Eric Percle
    Days from application to issue
    0
    Expires
    Sep 12, 2019
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  44. Permit Electrical Repair / Replacement / Addition Permit Issued

    Renovations to interior

    Permit
    19-00739-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $8,000
    Fees
    $412
    Contractor
    Stephen Michael Guillot
    Days from application to issue
    1
    Expires
    Jul 9, 2019
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  45. Permit VCC Sign Permit Finaled

    • To install one (1) double-faced aluminum or steel sign to read “Slush Frozen Cocktails Epic Fires ” per drawings stamped VCC approved 01/28/19 • Sign will measure: 3’8” w x 3’ h x 1’10” thickness • Sign will hang perpendicular to the street, from existing mast arm • Sign will hang from chains • Top portion of sign will have a white background with multi-colored lettering reading “Slush”. “Slush” letters to be illuminated channel letters with translucent faces. LEDs behind letters to only feature consistent white light at 3000K color temperature and 80+ color rendering index. Top portion of sign will also feature blue vinyl lettering reading “Frozen Cocktails”. • Bottom portion of sign will have a yellow background with horizontal yellow colored neon lines. Bottom portion will feature red neon lettering reading “Epic Fries”. • No additional illumination or lighting is approved Note: All existing signs must be removed and no additional signs may be installed. The bottom of the sign shall be at least 7’-0” above the surface of the sidewalk beneath it. Signs shall not extend beyond 4'-0" from the building face.

    Permit
    18-41442-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    47
    Expires
    Aug 5, 2019

    See this permit on One Stop

  46. Permit Attached Sign Permit Issued

    Install new sign for business

    Permit
    18-41442-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $345
    Contractor
    A-1 Signs Inc
    Days from application to issue
    49
    Expires
    Aug 6, 2019
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  47. Permit Mechanical HVAC Permit Finaled

    (2) 15 Ton Air Conditioning Systems with 20 kw heat

    Permit
    18-40122-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $14,000
    Fees
    $191
    Days from application to issue
    0
    Expires
    Jun 7, 2019
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  48. Permit Street Cut Other

    Install fiber optic cable for Creole Cuisine

    Permit
    18-29603-RSTC
    Type
    Street Cut
    Work
    Street Cut
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    815
    Expires
    May 30, 2021

    See this permit on One Stop

  49. Permit VCC Sign Permit Cancelled

    To retain as the single business sign for 607 Bourbon hanging on existing bracket. "Huge Ass Beers" sign 25" x 30"

    Permit
    18-28490-VCSGN
    Type
    VCC Sign
    Work
    VCC Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  50. Permit VCC General Work Permit Cancelled

    VCC application to retain awning installed on Dauphine side of building without a permit.

    Permit
    18-28486-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  51. Permit Renovation (Non-Structural) Other

    Interior repair work only including painting the entire interior, installation of new floors, installation of new bar counter top and new tile floors in the restrooms.

    Permit
    18-29098-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $73,000
    Fees
    $425
    Days from application to issue
    0
    Expires
    Feb 28, 2019
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Permit approved
    5. Issue date
    6. First inspection

    See this permit on One Stop

  52. Permit Attached Sign Other

    To retain as the single business sign for 607 Bourbon hanging on existing bracket. "Huge Ass Beers" sign 25" x 30"

    Permit
    18-28490-SATT
    Type
    Attached Sign
    Work
    Attached Sign
    Estimated cost (applicant’s figure)
    $0
    Fees
    $285
    1. Application submitted

    See this permit on One Stop

  53. Permit Renovation (Non-Structural) Other

    VCC application to retain awning installed on Dauphine side of building without a permit.

    Permit
    18-28486-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $0
    Fees
    $90
    1. Application submitted

    See this permit on One Stop

  54. Permit Renovation (Non-Structural) Other

    Place Uniti HH at MMP at ROW of Toulouse Street and leave 150' slack. Trench 5' from the right of way to the side of the building, then rise up 10' in existing conduit and penetrate into closed courtyard area. Pull fiber along inside wall 75' in EMT, penetrate into the 2nd Floor. Pull another 25' to 2nd Floor Telco Closet Backboard and leave 50' slack. Construction 2-3 days/12 ct. MPO - Customer to install Space & Power. UF contractor will need to pull an additional pull string through existing conduit. UF will notify property at least 24 hours prior to construction. Ground conditions will be restored to existing or better conditions.

    Permit
    18-27347-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $85
    Contractor
    Southern Light LLC
    Days from application to issue
    93
    Expires
    May 20, 2019
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  55. Permit VCC General Work Permit Cancelled

    To renovate building and correct violations as per materials stamped VCC approved 08/28/18. Work includes: • Repairing/replacing deteriorated woodwork to exactly match existing including storefront windows, doors, vitrines, and balcony fascia • Repairing/replacing gutter and downspout on the Bourbon elevation of the 811 Toulouse building • Removing all unused wires from the building’s exterior • Removing all unpermitted signage • Painting all repaired/replaced woodwork to match existing color…white, semigloss All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.

    Permit
    18-25433-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    26
    Expires
    Feb 28, 2019

    See this permit on One Stop

  56. Permit Renovation (Non-Structural) Permit Cancelled

    Repairs in response to VCC Case No.: 18-4991-DBNVCC for the following municipal addresses: 601, 605, 609 Bourbon Street and 811 Toulouse Street. The purpose of this permit is to remedy and include the following: 1. 166-121. Windows. Repair storefront window. 2. 166-121. Doors. Repair doors on Bourbon Street. 3. 166-121. Balconies. Repair deterioration on 811 Toulouse building. 4. 166-121. Paint. Repair paint deterioration. 5. 166-121. Gutters. Repair gutter and downspout on Bourbon street. 6. 166-35. Awnings. Installation of awning on second story of Dauphine elevation at 811 Toulouse. 7. 166-35. Lighting. Replace exterior light fixtures with shielded fixtures on 605 and 609 Bourbon street. 8. 166-35. Windows. Remove plywood installed in window. 9. 166-35. Wires. Remove unused wires and paint necessary cables to match building. 10. 166-80. Permit required for signs. Need to apply for sign permit, if one is not already applied and approved. 11. 166-77. General Prohibition of Misc. Signs. Impermissible exit sign. 12. 166-84. Signs shall not be placed on fence. Regarding the aforementioned exit sign. 13. 166-125. Merchandising of certain items. Hanging merchandise on the doors and shutters. All to be removed.

    Permit
    18-25433-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,500
    Fees
    $150
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review

    See this permit on One Stop

  57. Permit VCC Paint Permit Cancelled

    Utility (Entergy Gas) work required to convert customer onto new High Pressure gas lines being installed with City Reconstruction Project. A gas service line will be installed from sidewalk base and elbow into building for gas supply. An iron curb valve access port will be installed at sidewalk surface with below grade valve for emergency service isolation. Per application and materials recieved 4/10/18 adn stamped VCC approved 4/12/18. The new line will be painted to match the adjacent surface.

    Permit
    18-12040-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    Oct 12, 2018

    See this permit on One Stop

  58. Permit VCC Paint Permit Cancelled

    Utility (Entergy Gas) work required to convert customer onto new High Pressure gas lines being installed with City Reconstruction Project. A gas service line will be installed from sidewalk base and elbow into building for gas supply. An iron curb valve access port will be installed at sidewalk surface with below grade valve for emergency service isolation. Per application and materials recieved 4/10/18 and stamped VCC approved 4/12/18. The new line will be painted to match the adjacent surface.

    Permit
    18-12039-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    Oct 12, 2018

    See this permit on One Stop

  59. Permit VCC Paint Permit Finaled

    • Walls...Pirates Gold, flat or satin finish • Wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery...white, semigloss • Shutters…Barracks Grey, semigloss

    Permit
    14-24465-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Feb 5, 2015

    See this permit on One Stop

  60. Permit VCC General Work Permit Issued

    Remove seven (7) existing pairs of floodlights on facade of building; Replace with six (6) pairs of shielded floodlights, using "Affordable Lamps" fixtures shown in drawing received with application 6/10/13 and stamped VCC approved on 6/12/13. Two sets of floodlights to go over doorway, two over vitrine/display window, and two at edge of roof. Remove metal alarm box over doorway. Repaint dormers and trim: color to be white. Replace missing slate in kind on sides of dormers. Remove vegetation from brick masonry, and re-mortar/stucco where necessary, using appropriate soft lime mortar mix (see formula below.) Repair rotten/missing wood trim on vitrine/display window to match existing, and repaint: color to be white.

    Permit
    13-18220-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $1,789
    Fees
    $0
    Days from application to issue
    0
    Expires
    Dec 12, 2013

    See this permit on One Stop

  61. Permit Electrical Service / Circuit / Feeder Permit Issued

    Work Descripton: ADD CIRCUITS- 11COM-00985 Historical Import Type: Permits Electrical Commercial Service-Circuits-Feeders User: DMFOLEY Tracking: 86156848137 Status: Permit Issuance Active Status Date: 4/26/2012 12:00:00 AM Owner: Mintz Willie Owner Address: 5529 Magazine St, New Orleans, LA 70115 Owner Edited By: 4/26/2012 by DMFOLEY

    Permit
    12ELC-04685
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $52
    Contractor
    Pelican Elect Contr
    Days from application to issue
    0
    Expires
    Oct 26, 2012

    See this permit on One Stop

  62. Permit General Mechanical Inspection Phase

    Work Descripton: new gasline;2-deepfryers/1-griddle/david /ck#11162. Historical Import Type: Permits Mechanical Residential General Mechanical User: RHARDOUIN Tracking: 186176556162 Status: Meter Released Status Date: 12/21/2011 12:00:00 AM Owner: Mintz Willie Owner Address: 5529 Magazine St, New Orleans, LA 70115 Owner Edited By: 12/16/2011 by RHARDOUIN

    Permit
    11MCH-10128
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $75
    Contractor
    David Carter's Plbg LLC
    Expires
    Jun 21, 2012
  63. Permit Mechanical Closed

    INSTALL KITCHEN HOOD. JOHN WOOD (#1587)

    Permit
    11MCH-10099
    Type
    Mechanical
    Work
    Hoods
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
  64. Permit Electrical Permit Issuance Active

    UPGRADE- 11COM-00985

    Permit
    11ELC-12441
    Type
    Electrical
    Work
    Service-Circuits-Feeders
    Estimated cost (applicant’s figure)
    $0
    Fees
    $49
  65. Permit Commercial Permit Issuance Active

    REMOVE/REPLACE OLD KITCHEN HOOD SYSTEM ALONG WITH NEW FIRE SYSTEM AS PER SKETCH AND STATE FIRE MARSHALL APPROVAL. NO EXTERIOR WORK ALLOWED UNDER THIS PERMIT.

    Permit
    11COM-01560
    Type
    Commercial
    Work
    NA
    Estimated cost (applicant’s figure)
    $10,000
    Fees
    $110
  66. Permit Commercial Permit Issuance Active

    INTERIOR RENOVATIONS IN THE KITCHEN AREA, NEW EQUIPMENT,NEW FRYERS,GRILL;HOOD AND SINKS.

    Permit
    11COM-00985
    Type
    Commercial
    Work
    NA
    Estimated cost (applicant’s figure)
    $35,000
    Fees
    $235
  67. Code enforcement Case ENVHADJ-994171F Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 26-27524-VCPNT.

  68. Code enforcement Case ENVHADJ-20001819F Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 26-27524-VCPNT.

  69. Code enforcement Case ENVHADJ-2000355F Closed

    The property was inspected on 12/03/1999 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 26-27524-VCPNT.

  70. Permit Mechanical Annual Fee Pending
    Permit
    03MCH-06679
    Type
    Mechanical
    Work
    Stationary Equipment Annual
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
  71. Permit Sign

    PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2004 PAID FOR 1

    Permit
    S04000660
    Type
    Sign
    Days from application to issue
    0
  72. Permit Sign

    PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1

    Permit
    S04000071
    Type
    Sign
    Days from application to issue
    0
  73. Permit Electrical

    ELECTRICAL VACANCY REPAIRS RETAIL STORE FRED VANLANGENDONCK

    Permit
    E03007229
    Type
    Electrical
    Days from application to issue
    0

    Placed here by the building address from “811 TOULOUSE ST UNIT D”.

  74. Permit Sign

    PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2003 PAID FOR 1

    Permit
    S03000748
    Type
    Sign
    Days from application to issue
    0
  75. Permit Sign

    PROJECTING SIGN RETAIL STORE SIGN FEE 2003

    Permit
    S03000048
    Type
    Sign
    Days from application to issue
    0
  76. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT RESTAURANT 49 AND UNDER INSTALLATION OF 6 TON A/C UNIT. RONALD 469-3760.

    Permit
    M02004929
    Type
    Mechanical
    Days from application to issue
    3
  77. Permit Building

    RE-ROOF (COMMERCIAL) MIXED OCCUPANCY ROOF REPLACEMENT AS PER VCC # 020282

    Permit
    B02003340
    Type
    Building
  78. Permit Building

    RE-ROOF (COMMERCIAL) MIXED OCCUPANCY REROOF EXISTING MIXED USE BUILDING PER VCC #020282

    Permit
    B02003341
    Type
    Building
  79. Permit Building

    RE-ROOF (COMMERCIAL) MIXED OCCUPANCY REROOF EXISTING MIXED USE BUILDING PER VCC # 020282

    Permit
    B02003343
    Type
    Building
    Days from application to issue
    8
  80. Permit Building

    RE-ROOF (COMMERCIAL) BAR/COCKTAIL REROOF EXISTING BAR AS PER VCC 020281

    Permit
    B02003344
    Type
    Building
    Days from application to issue
    8
  81. Permit Sign

    PROJECTING SIGN RETAIL STORE SIGN FEES 2002 PAID

    Permit
    S02000153
    Type
    Sign
    Days from application to issue
    0
  82. Permit Sign

    PROJECTING SIGN BAR/COCKTAIL SIGN FEES 2002 PAID

    Permit
    S02000129
    Type
    Sign
    Days from application to issue
    0
  83. Permit Sign

    PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2001 PAID

    Permit
    S01000485
    Type
    Sign
    Days from application to issue
    0
  84. Permit Sign

    PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID

    Permit
    S01000080
    Type
    Sign
    Days from application to issue
    0
  85. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING

    Permit
    M99003597
    Type
    Mechanical
  86. Permit Sign

    PROJECTING SIGN RETAIL STORE SIGN OPERATING FEE FOR 1998

    Permit
    S98000545
    Type
    Sign