French Quarter
908 Bourbon Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 42 permits on record here; the most recent, a VCC general work permit, was filed in March 2026. 28 are still open. There was 1 past code enforcement case, the latest in October 2011, all closed. On this block in the past year: 4 requests to 311 and 141 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 4,427 sq ft
- Parcel
- 41022471
Everything on record here
43 records, newest first · 28 open
-
Permit VCC General Work Permit Issued
Remove existing roofing material Repair and/or replace underlayment as necessary Install new CUPA natural slate (grey/black), using copper nails Install all new copper flashing flashing, chimney and valley PERMIT DOES NOT INCLUDE NEW GUTTERS AND DOWNSPOUTS Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Metal cap-flashing on the parapets or chimneys is not allowed install new GRAY TPO in valley behind parapet. TPO is not to come up parapet wall Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 26-08056-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- All Ways Roofing, LLC
- Days from application to issue
- 3
- Expires
- Sep 26, 2026
-
Permit Renovation (Non-Structural) Permit Issued
Remove existing slate roof. Install new, S1 grade “CUPA 14” slate roof with copper nails a flashings. PLEASE NOTE: Re-roofing permits DO NOT require an inspection from Safety and Permits, instead please upload the following photos to this permit PHOTOS REQUIRED 4 geotagged photos (one from each side) showing: -Removal of existing roof material -Installation of water intrusion resistant underlayment -Installation of the drip-edge and flashing -Installation of shingles or metal panels Once all applicable photos have been uploaded to the permit, please email requesting permit closure.
- Permit
- 26-08056-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $49,000
- Fees
- $548
- Contractor
- All Ways Roofing, LLC
- Days from application to issue
- 120
- Expires
- Jan 16, 2027
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
Placed here by an address range from “908-910 Bourbon St”.
-
Permit VCC General Work In Review
Remove synthetic slate roof and install CUPA 14 natural slate roof with copper nails, copper flashings.
- Permit
- 26-07633-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Residential Re-Roofing Other
Remove synthetic slate roof and install CUPA 14 natural slate roof with copper nails, copper flashings.
- Permit
- 26-07633-ROOF
- Type
- Residential Re-Roofing
- Work
- Residential Re-Roofing
- Estimated cost (applicant’s figure)
- $0
- Fees
- $60
- Contractor
- All Ways Roofing, LLC
- Application submitted
-
Permit Electrical Service / Circuit / Feeder Other
Replace failed utility disconnect and damaged feeders. Will require emergency reconnect. Business has refrigeration with no power.
- Permit
- 25-22975-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $100
- Contractor
- Keith Frederick Perrin
- Days from application to issue
- 3
- Expires
- Feb 1, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work In Review
Emergency permit: sound stucco, repoint (using VCC mortar formula), and restucco rear wall of structure to match in thickness, profile, and texture of finished stucco to match existing. pieces of stucco falling from wall onto neighboring properties. Pictures to follow.
- Permit
- 25-12791-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Emergency permit: sound stucco, repoint (using VCC mortar formula), and restucco rear wall of structure to match in thickness, profile, and texture of finished stucco to match existing. pieces of stucco falling from wall onto neighboring properties. Pictures to follow.
- Permit
- 25-12791-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $220
- Contractor
- Kendall Ward
- Application submitted
-
Permit VCC General Work Permit Issued
Remove existing Fire Free Plus roofing material Repair and/or replace underlayment as necessary Install new 18” x 12” CUPA natural slate (black, per manufacturer's specificaitons Install/repair half round copper gutters and flashing where necessary Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 24-33567-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 2
- Expires
- May 6, 2025
-
Permit Renovation (Non-Structural) Other
Remove Existing Synthetic-Slate "Fire-Free" Roof. Install New, S1-Grade Natural Slate Roof "CUPA" Black.
- Permit
- 24-33567-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $45,000
- Fees
- $518
- Contractor
- All Ways Roofing LLC
- Application submitted
- Zoning review
-
Permit VCC General Work In Review
Remove Existing Synthetic-Slate "Fire-Free" Roof. Install "PERMALOCK" Metal Shingle Roof with Slate-Profile. Remove, Clean and Re-install Historic Ridge Tile.
- Permit
- 24-23196-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) In Review
Remove Existing Synthetic-Slate "Fire-Free" Roof. Install "PERMALOCK" Metal Shingle Roof with Slate-Profile. Remove, Clean and Re-install Historic Ridge Tile.
- Permit
- 24-23196-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $45,000
- Fees
- $518
- Contractor
- All Ways Roofing LLC
- Application submitted
- Zoning review
-
Permit VCC General Work Permit Issued
To repair/replace stucco on the rear elevation of the service ell, per materials stamped VCC approved 05/15/2024. Work includes: • Sounding stucco to remove and unsound sections • Repointing/repair underlying bricks, replacing cracked or missing bricks with new matching bricks • Applying new stucco as per VCC standard details
- Permit
- 24-12305-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 16
- Expires
- Nov 15, 2024
-
Permit Renovation (Non-Structural) Permit Issued
Remove stucco, repoint with VCC mortar mix, replace damaged bricks to match in size, color, and hardness. restucco entire wall with three coats of VCC stucco mix.
- Permit
- 24-12305-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $8,000
- Fees
- $240
- Contractor
- Kendall Ward
- Days from application to issue
- 22
- Expires
- Nov 17, 2024
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Finaled
• Remove all existing, unpermitted and/or unshielded light fixtures • Install four (4) Nicor model 11512 single bullet lights to the underside of the balcony • Two (2) fixtures to be centered over the door openings with fixtures aimed straight down • Two (2) fixtures to be installed between the door centers and the sign with the fixtures aimed at the sign face • Fixtures shall be painted or prefinished to match adjacent building surface. • All wiring shall be placed in conduits • All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. • All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800-1200 lumens per bulb • Repair existing wood louvered shutters on the ground floor of the Bourbon St. elevation to match existing. Repaint shutters as needed to match existing All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon
- Permit
- 18-41431-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 165
- Expires
- Dec 3, 2019
-
Permit Renovation (Non-Structural) Other
Non-structural repairs to mixed use structure. Repairs include electrical, shutters, as per VCC approval.
- Permit
- 18-41431-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $700
- Fees
- $98
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
-
Permit VCC General Work Permit Finaled
repair balcony railings, to match existing repair cracked plaster and/or delaminated plaster and install new stucco using VCC stucco formula (attached), as needed repair trim and columns where needed, to match existing repair and reinstall shutters where needed, to match existing remove all vegitation Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). ALL PAINT TO MATCH EXISTING All repair/replacement work shall match existing in color, size, material, detail, profile and exposure NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
- Permit
- 18-27785-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 24, 2019
-
Permit Renovation (Non-Structural) Other
exterior- repair balcony decking, railing, trim, and columns as needed repair and reinstall shutters as needed, remove vegetation and paint parapet (see work description) interior- 2nd and 3rd floor only- demo and replace wood floors, repoint and repair plaster, drywall and paint as needed
- Permit
- 18-27785-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $24,861
- Fees
- $278
- Contractor
- Ransdell Chuck
- Days from application to issue
- 2
- Expires
- Feb 24, 2019
- Application submitted
- Application review
- Zoning review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Cancelled
This permit is being requested pursuant to a notice of violations issued by the City of New Orleans, case no.: 17-03506-DBNVCC. Minor repairs to remedy the following: 1. 166-121. Shutters. Repair 2nd and 3rd floor shutters with matching color and style. 2. 166-121. Stucco. Repair to deteriorated and missing stucco.
- Permit
- 17-43566-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Correct exterior violations as per case 17-03506-DBNVCC: Repair 2nd and 3rd floor shutters with matching color and style; repair deteriorated and missing stucco.
- Permit
- 17-43566-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $128
-
Permit VCC General Work In Review
replace flood lights with approved shielded lights. repaint lower portion of wall white, paint wires to match balcony and wall remove boards holding existing light under balcony
- Permit
- 17-32200-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Permit Issued
To repair/replace masonry headers as needed on the Dumaine elevation of the building, installing new steel lintels as needed and finishing in wood trim to match existing adjacent window details exactly. All mortar to be mixed according to the VCC standard details (attached). All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
- Permit
- 16-22198-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 8
- Expires
- Jan 26, 2017
-
Permit General Mechanical Permit Finaled
gas line and wh/ jeremy/ ck3420/ 302for350
- Permit
- 15-03828-MECH
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $35
- Contractor
- Jeremy Ferret
- Days from application to issue
- 0
- Expires
- Aug 6, 2015
-
Permit General Mechanical Permit Finaled
waf and ac/ sid467-1400/ ck24831/ 302for350/ 14-33551-RNVN
- Permit
- 15-02974-MECH
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $65
- Contractor
- Sidney Lee
- Days from application to issue
- 0
- Expires
- Jul 29, 2015
-
Permit Electrical Service / Circuit / Feeder Permit Finaled
rewire 14-33551-RNVN
- Permit
- 14-38710-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $115
- Contractor
- Joshua Elliot Brockhaus Sr
- Days from application to issue
- 0
- Expires
- Jun 15, 2015
-
Permit Renovation (Non-Structural) Occupancy
Interior renovation to existing apartment(slave quarter) - paint, tile, new fixtures, and re-finish flooring. NO EXTERIOR WORK UNDER THIS PERMIT.
- Permit
- 14-33551-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $62,476
- Fees
- $375
- Contractor
- Carimi Construction & Development LLC
- Days from application to issue
- 0
- Expires
- Apr 29, 2015
-
Permit VCC Sign Permit Issued
-temp sign for filming
- Permit
- 13-07696-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Sep 12, 2013
-
Permit VCC Sign Permit Issued
Another new sign: NOLA Poboys - Install one business sign, with backlit channel lettering - Sign is to measure 40”w x 16”h x 7”d and to be mounted to the building’s façade with a new, 1 ½” steel tube pole mount and 3/8” steel cable support. - Sign is to be constructed of aluminum panels mounted to an aluminum frame, with reverse channel letters reading “Sloppy Roast Beef- Spicy Shrimp- Boudin- Sweets: NOLA POBOYS” and letters below reading “Convenience Store.” -Illumination will be provided by LED lighting within each channel letter, creating a halo effect. Note: Sign must not extend beyond 4’ from the face of the building. All existing signs must be removed. The bottom of the sign shall be at least 9'0" above the surface of the sidewalk beneath it.
- Permit
- 12-22836-VCSGN
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 22, 2013
-
Permit VCC General Work Other
Historical Import Type: Enforcement VCC Permit General User: TMCLEOD Tracking: 86110296818 Status: Permit Issued Status Date: 6/5/2012 12:00:00 AM Owner: James & Richard Realty Owner Address: Holdings LLC 901 Tchoupitoulas, New Orleans, LA 70130 Owner Edited By: 6/5/2012 by TMCLEOD - Repair existing louvered shutters on the ground floor as needed on the Bourbon St façade and paint to match existing. - Repair beaded board and batten shutters on the second and third floor of the Bourbon St. facade. Paint to match existing - Install new beaded board and batten shutters on the second and third floor of the Bourbon St facade to match existing adjacent shutters. Paint to match existing adjacent shutters. APPLICANT MUST SUBMIT MILL WORK SHOP DRAWINGS FOR NEW MILLWORK PRIOR TO FABRICATION AND INSTALLATION NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
- Permit
- VCCP-12-0527
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC Paint Other
Historical Import Type: Enforcement VCC Permit Paint User: RPELL Tracking: 86171519076 Status: Permit Issued Status Date: 2/17/2012 12:00:00 AM Owner: James & Richard Realty Owner Address: Holdings LLC 901 Tchoupitoulas, New Orleans, LA 70130 Owner Edited By: 2/17/2012 by RPELL • Walls, flat or satin finish, White to match existing SW 7077 • Wooden elements including doors, windows, frames, shop windows, fascia /soffit/outriggers of gallery..., semigloss, White to match existing SW 7077 • Shutters ,semigloss, Rockwood Green to match existing, SW2809 • Ironwork, Black as night. SW 6993
- Permit
- VCCP-12-0164
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Other
Historical Import Type: Enforcement VCC Permit General User: RPELL Tracking: 86111737580 Status: Permit Issued Status Date: 2/17/2012 12:00:00 AM Owner: James & Richard Realty Owner Address: Holdings LLC 901 Tchoupitoulas, New Orleans, LA 70130 Owner Edited By: 2/17/2012 by RPELL Repair existing louvered shutters on the ground floor as needed on the Bourbon St façade and paint to match existing. - Repair beaded board and batten shutters on the second and third floor of the Bourbon St. facade. Paint to match existing - Install new beaded board and batten shutters on the second and third floor of the Bourbon St facade to match existing adjacent shutters. Paint to match existing adjacent shutters. APPLICANT MUST SUBMIT MILL WORK SHOP DRAWINGS FOR NEW MILLWORK PRIOR TO FABRICATION AND INSTALLATION NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
- Permit
- VCCP-12-0168
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC Sign Other
Historical Import Type: Enforcement VCC Permit Sign User: RPELL Tracking: 86141766245 Status: Permit Issued Status Date: 2/7/2012 12:00:00 AM Owner: James & Richard Realty Owner Address: Holdings LLC 901 Tchoupitoulas, New Orleans, LA 70130 Owner Edited By: 2/7/2012 by RPELL Install one business sign, with backlit channel lettering - Sign is to measure 40”w x 16”h x 7”d and to be mounted to the building’s façade with a new, 1 ½” steel tube pole mount and 3/8” steel cable support. - Sign is to be constructed of aluminum panels mounted to an aluminum frame, with reverse channel letters reading “Cafe' Iguana,” and black PVC letters attached below reading, “TexMex - Barbeque - Cajun.” -Illumination will be provided by LED lighting within each channel letter, creating a halo effect.
- Permit
- VCCP-12-0121
- Type
- VCC Sign
- Work
- VCC Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Other
Historical Import Type: Enforcement VCC Permit General User: RPELL Tracking: 86186525218 Status: Permit Issued Status Date: 2/3/2012 12:00:00 AM Owner: James & Richard Realty Owner Address: Holdings LLC 901 Tchoupitoulas, New Orleans, LA 70130 Owner Edited By: 2/3/2012 by RPELL - Stucco existing openings with 3 part cement stucco over sheathing on a metal stud frame on the rear elevation of the rear service building. - Stucco surface will be recessed 1" from the face of the rear wall of the service building.
- Permit
- VCCP-12-0107
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Code enforcement Case CEHB-11-7682 Closed
A hearing was held on 12/06/2011 with a result of "Guilty: Public Nuisance Blight".
- Hearing: Initial Hearing Guilty: Public Nuisance Blight
- Hearing: Reset Hearing Guilty: Public Nuisance Blight
The city links this case to permit 26-08056-RNVN.
-
Permit Attached Sign Permit Issuance - Active
Installation of new hanging sign at 908 Bourbon St. "Candy Bar" illuminated sign (16"x40") as per sketch and VCC approval (VCCP-10-0486)
- Permit
- 10SIG-00167
- Type
- Attached Sign
- Work
- NA
- Estimated cost (applicant’s figure)
- $3,500
- Fees
- $260
- Days from application to issue
- 0
-
Permit General Mechanical Inspection - Completed
INSTALL 4-ELEC WAF AND FOUR A\C. (#10COM-00731 CRAIG JOHNSON (#27871) CRAIG JOHNSON
- Permit
- 10MCH-06610
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $192
- Contractor
- Crescent City Air Inc., Dba
- Days from application to issue
- 5
-
Permit Mechanical Permit Issuance Active
INSTALL ELEC WATER HEATER. LEON MOLINARIO (#24062) (#10COM-00731)
- Permit
- 10MCH-06004
- Type
- Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $20
-
Permit Electrical Service / Circuit / Feeder Permit Issuance - Active
INCREAS SERVICE 10COM-00731
- Permit
- 10ELC-05803
- Type
- Electrical Service / Circuit / Feeder
- Work
- Service-Circuits-Feeders
- Estimated cost (applicant’s figure)
- $0
- Fees
- $136
- Contractor
- Carr's Electric
- Days from application to issue
- 0
-
Permit Renovation (Non-Structural) Inspection - Completed
INTERIOR NON-STRUCTURAL RENOVATIONS TO THE RETAIL SPACE(908 BOURBON ST) IN EXISTING MIX USE BUILDING(1-COMMERCIAL SPACE AND 2- RESIDENTIAL SPACES) - REPAIR WALLS, FLOORS, PLUMBING, ELECTRICAL, HVAC, AND PAINT AS PER STATE HEALTH DEPARTMENT AND STATE FIRE MARSHAL APPROVAL. NO EXTERIOR WORK UNDER THIS PERMIT. (908-10 BOURBON ST)
- Permit
- 10COM-00731
- Type
- Renovation (Non-Structural)
- Work
- NA
- Estimated cost (applicant’s figure)
- $50,000
- Fees
- $310
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004 PAID FOR 1
- Permit
- S04000593
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE PAID FOR 1
- Permit
- S03000621
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEES
- Permit
- S02000293
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000372
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN OPERATING FEE FOR 1998
- Permit
- S98000294
- Type
- Sign