French Quarter
915 Bourbon Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 7 permits on record here; the most recent, a renovation (non-structural) permit, was filed in September 2021. 5 are still open. On this block in the past year: 4 requests to 311 and 141 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 6,202 sq ft
- Parcel
- 41022474
Everything on record here
7 records, newest first · 5 open
-
Permit Renovation (Non-Structural) Application Accepted
Repair cracks in exterior stucco walls of main house using VCC approved material. Match existing scored stucco finish.
- Permit
- 21-26588-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,500
- Fees
- $120
- Contractor
- Kirk C. Vallery
- Application submitted
-
Permit VCC General Work In Review
remove and replace all lose existing stucco on the parapet wall and the sidewall below the parapet. tuckpoint the brick as necessary using VCC approved mix Apply stucco finish to match as existing using VCC approved stucco mix To replace all missing slate shíngles to match as existng where necessary. To fabricate and install an apron flashing made out of copper sheet metal on one existing window to stop water from going inside the building, to match existing To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHI
- Permit
- 20-33736-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
The Scope of Work: 1. To pull off all lose existing stucco on the parapet wall also the sidewall below the parapet. 2. To tuckpoint the brick as necessary using the VCC mix over the areas where water is going inside the parapet wall. Apply masonry finish to match as existing. 3. To replace all missing slate shíngles matching as existing. 4. To fabricate and install an apron flashing made out of copper sheet metal on one existing window to stop water from going inside the building.
- Permit
- 20-33736-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $113
- Application submitted
- Application review
-
Permit General Mechanical Permit Finaled
install elect warm air furnace and a/c Robert Ronald (#046512) 15-01621-VCGEN
- Permit
- 15-02823-MECH
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $65
- Contractor
- Ron Robert Jr
- Days from application to issue
- 0
- Expires
- Jul 28, 2015
-
Permit VCC General Work Permit Issued
Remove existing two-ton package unit on unrated, rear addition Install in same location new two-ton package (model #4TCY4024/030), per specifications stamped VCC approved 01/21/15 Note: White screening will be removed; replacement of the screen must be reviewed by the VCC.
- Permit
- 15-01621-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Ron Robert Jr
- Days from application to issue
- 6
- Expires
- Jul 21, 2015
-
Permit VCC General Work Permit Issued
Install security cameras To install two (2) Aposonic A-E650V 650 TV-line Sony Exview II surveillance cameras per cut sheet stamped approved (attached). -Cameras are to be mounted to either side of abat-vent (upriver and downriver corners) on Bourbon Street elevation. -Wiring is to be painted the same color as the adjacent building surface.
- Permit
- 12-23173-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 24, 2013
-
Permit VCC Paint Other
Historical Import Type: Enforcement VCC Permit Paint User: HIRVIN Tracking: 86197335698 Status: Permit Issued Status Date: 6/18/2012 12:00:00 AM Owner: Jaffe Bernard M Owner Address: 915 Bourbon St, New Orleans, LA 70116 Owner Edited By: 6/18/2012 by HIRVIN As follows to match existing conditions: 1. Stucco walls...light gray 2. Wainscoting (front facade)...dark gray 3. Shutters/ironwork...deep aquamarine 4. Trim...white 5. Front door...wood stain to match exisitng and past conditions
- Permit
- VCCP-12-0572
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0