French Quarter

1205 Bourbon Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 6 permits on record here; the most recent, a VCC general work permit, was filed in April 2018. 3 are still open. There was 1 past code enforcement case, the latest in April 2009, all closed. On this block in the past year: 10 requests to 311 and 42 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
6
Lot size
2,715 sq ft
Parcel
41022491

Everything on record here

7 records, newest first · 3 open

  1. Permit VCC General Work Permit Issued

    Install 4 dome style security cameras on the four corners of the main building to soffit.

    Permit
    18-11489-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Oct 5, 2018

    See this permit on One Stop

  2. Permit VCC General Work Permit Issued

    Repoint masonry throughout property as needed, using VCC mortar formula, attached. Repair stucco wainscot on rear building to match existing, using VCC stucco formula, attached. Parge coat front elevation of main house on Bourbon only, using thin coats of VCC mortar formula to protect exposed brick. Paint permit to be issued separately. Remove vegetation from masonry. Cut vegetation down and apply “RoundUp” or equal. Remove dead roots after 1-2 days, once the roots have shriveled. Install new VCC mortar as needed where deteriorated All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Failure to exactly match materials or VCC mortar/stucco as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted.

    Permit
    17-36720-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Kendall Ward
    Days from application to issue
    71
    Expires
    Jul 5, 2018

    See this permit on One Stop

  3. Permit VCC General Work Permit Issued

    Repair 2nd story windows as needed to match existing.

    Permit
    17-36709-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Apr 26, 2018

    See this permit on One Stop

  4. Permit VCC Paint Permit Finaled

    Walls: Stonington Gray HC-170, flat or satin finish Shutters: Lafayette Green HC-135 Doors, Trim and Windows: Snowbound SW 7004 Ironwork: Black Foundation: Corentry Gray HC-169

    Permit
    15-26428-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $1,750
    Fees
    $0
    Days from application to issue
    0
    Expires
    Mar 2, 2016

    See this permit on One Stop

  5. Permit VCC General Work Permit Issued

    Remove broken slate where necessary Repair and/or replace underlayment if necessary Remove any galvanized flashing, replace all galvanized materials with copper equivalent Install new natural slate (grey/green), using copper nails, where needed Install/repair copper gutters, flashing and vents, Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles, as needed Paint plastered chimney with dark gray latex paint. Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.

    Permit
    15-21689-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    4
    Expires
    Feb 4, 2016

    See this permit on One Stop

  6. Permit Renovation (Non-Structural) In Review

    Roof repairs and flashing

    Permit
    15-21689-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $3,460
    Fees
    $120

    See this permit on One Stop

  7. Code enforcement Case ENVHADJ-2001438SN Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 15-21689-VCGEN.