French Quarter

824 Burgundy Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 16 permits on record here; the most recent, a VCC paint permit, was filed in October 2025. 13 are still open. On this block in the past year: 6 requests to 311 and 29 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
4,776 sq ft
Parcel
41022548

Everything on record here

16 records, newest first · 13 open

  1. Permit VCC Paint Permit Issued

    On Burgundy elevation, as needed: Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). Paint balconies and railings to match existing color and finish. NOTE: If outriggers are to be painted, they must be painted white, not black. Outriggers under balconies or galleries should be painted white as they are not decorative ironwork elements. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure unless otherwise noted.

    Permit
    25-32518-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Couvillion Construction Group, Inc. dba Couvillion Construction Group, Inc.
    Days from application to issue
    19
    Expires
    May 4, 2026

    See this permit on One Stop

  2. Permit Dumpster/Construction Zone Permit Issued

    I am selling my condo and need a Pods Storage container to be on the street outside the building my condo is in. The dimensions. of the unit is 8x7x7.

    Permit
    25-13553-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $80
    Days from application to issue
    1
    Expires
    Nov 5, 2025

    See this permit on One Stop

  3. Permit VCC General Work Application Accepted

    Change metal chimney cap and metal cap flashing to address VCC violation

    Permit
    19-33962-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  4. Permit Renovation (Non-Structural) Other

    Change metal chimney cap and metal cap flashing to address VCC violation

    Permit
    19-33962-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $128
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Permit approved

    See this permit on One Stop

  5. Permit VCC General Work Other

    Replace half-round copper gutter at Burgundy side cornice to match existing. Paint Sussex Green, HC-109, flat or satin finish, to match existing wall color and finish.

    Permit
    19-07353-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Sep 8, 2019

    See this permit on One Stop

  6. Permit VCC General Work Permit Cancelled

    Retain metal cap on chimney Secure/seal chimney cap edges Paint to blend if necessary

    Permit
    18-09299-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  7. Permit VCC General Work Permit Issued

    To resolve VCC violations per case number 16-12368, as follows: Install new balcony decking, to match existing tongue and groove in size, profile, and dimension. Remove any unused wiring. Remaining wiring must be installed tightly and discretely and painted to match adjacent surface. To prepare for painting by washing using a low water pressure (400 psi max); sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: • Walls: Sussex Green, HC-109, flat or satin finish Gutters & downspouts: Sussex Green, HC-109, flat or satin finish • Wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery: white, semigloss • Shutters: Dark green, semigloss. Shutters must read as green, not black Balcony decking: Dark green, semigloss, to match shutters • Ironwork: black, gloss Failure to exactly match permit specified colors will result in a VCC violation and mandated repainting. This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastomeric coatings/paints, waterproofing/water repellent coatings.

    Permit
    17-11392-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Oct 4, 2017

    See this permit on One Stop

  8. Permit VCC General Work Permit Issued

    Install temporary shop-coated steel angle lintel, measuring 3 1/2" x 3 1/2" x 1/4" (compliant with requirements listed in ASTM A36), into masonry wall, three courses above existing wood lintel. Remove the three courses of brickwork and existing wood lintel. Square up bricks to the left and right of window jamb. Install new treated wood lintel, to match existing dimensions and exposure, painted to match trim using semigloss paint. Reinstall masonry above lintel, using VCC mortar formula (attached). Remove temporarily installed steel angle lintel. Contact VCC staff at for inspection before steel lintel is removed and work completed. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar forumla (attached). Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    16-21187-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $3,211
    Fees
    $0
    Contractor
    Richard Volker
    Days from application to issue
    22
    Expires
    Jan 21, 2017

    See this permit on One Stop

  9. Permit Renovation (Non-Structural) Other

    Non-structural exterior repairs to single family residence as per VCC approval.

    Permit
    16-21187-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $3,211
    Fees
    $120
    Contractor
    R Volker Waterproofing LLC

    See this permit on One Stop

  10. Permit VCC General Work Permit Issued

    -To remove all unpermiited metal cap-flashing and to install mortar caps with VCC approved mortar formula (below). -Wire mesh may be embedded in mortar cap to facilitate better weather-proofing. Mortar: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.

    Permit
    14-07810-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    5
    Expires
    Sep 12, 2014

    See this permit on One Stop

  11. Permit Electrical

    ELECTRICAL RECONNECT MULTI-FAMILY DWELLING GERALD BORDELON

    Permit
    E03002084
    Type
    Electrical
    Days from application to issue
    0

    Placed here by the building address from “824 BURGUNDY ST UNIT 8”.

  12. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING REPLACE ELEC WATER HEATER ALVIN LETO - 271-0764

    Permit
    M03000569
    Type
    Mechanical
    Days from application to issue
    0
  13. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING REPLACE ELEC WATER HEATER ALVIN LETO - 271-0764

    Permit
    M03000570
    Type
    Mechanical
    Days from application to issue
    0
  14. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING INSTALL 3-TON A\C SYSTEM AND ELEC WARM AIR FURNACE. EARL BOTSAY - 452-3490

    Permit
    M02006557
    Type
    Mechanical
    Days from application to issue
    1
  15. Permit Electrical

    CIRCUITS ONLY MULTI-FAMILY DWELLING JOHN WARD RELOCATION/REWIRE KITCHEN

    Permit
    E02008179
    Type
    Electrical
    Days from application to issue
    0
  16. Permit Building

    GENERAL REPAIRS CONDOMINIUM SINGLE FAMILY REPAIRS TO REAR UPPER SINGLE UNIT #6, WORK TO CONSIST OF: PAINTING, INSTALLING BATH & KITCHEN CABINETS, BEADED CEILING, SHEETROCK 2 RMS,NO EXTERIOR WORK ALLOWED

    Permit
    B02004970
    Type
    Building
    Days from application to issue
    0