French Quarter
827 Burgundy Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 18 permits on record here; the most recent, a dumpster/construction zone permit, was filed in August 2025. 11 are still open. There were 2 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 6 requests to 311 and 29 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 2,080 sq ft
- Parcel
- 41022549
Everything on record here
20 records, newest first · 11 open
-
Permit Dumpster/Construction Zone Application Accepted
Request to place an 8x16-foot dumpster on the sidewalk, In Front of the property for 2 days Thur Aug 28th & Fri Aug 29th... .... If the location being requested must be changed, please, please simply MARK the location where the dumpster must be placed and continue with issuance of the permit... 827 Burgundy... related to permit # 25-02732-rnvn
- Permit
- 25-25901-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Mackie One Construction LLC
-
Permit VCC General Work Permit Issued
Install a new SLATE roofing system (12"x18" gray/ green), chimney base flashing, copper wall & cap flashing & Flat Roofing per applicaiton and materials recieved 5/22/25 and stamped VCC approved 5/30/25. PLEASE BE AWARE the VCC does not allow metal cap flashing on parapets or chimneys. Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding wall. Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 25-02732-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 8
- Expires
- Nov 30, 2025
-
Permit Renovation (Non-Structural) Permit Issued
Install a new roofing system, chimney base flashing, copper wall & cap flashing & Flat Roofing
- Permit
- 25-02732-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $45,745
- Fees
- $350
- Contractor
- Mackie One Construction LLC
- Days from application to issue
- 130
- Expires
- Dec 6, 2025
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Finaled
Replace existing 2-ton system per attached materials stamped VCC approved 12/07/2022.
- Permit
- 22-33782-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 23
- Expires
- Jun 7, 2023
-
Permit Mechanical HVAC Permit Finaled
Replace HVAC system 2 ton.
- Permit
- 22-33782-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $8,500
- Fees
- $65
- Contractor
- MARTIN E HUGHES, SR.
- Days from application to issue
- 239
- Expires
- Jan 5, 2024
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Electrical Repair / Replacement / Addition Permit Issued
REPLACE FIXTURES
- Permit
- 17-07665-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Jesse Earl Carr Sr.
- Days from application to issue
- 0
- Expires
- Sep 7, 2017
-
Permit VCC General Work Permit Finaled
Remove unused or unecessary wiring on the front facade of the building. Walls...Peeble Stone, 759D-4,, oil-based paint in flat or satin finish Shutters & facade entrance door... Burnished Mahogany, semigloss (new shutters will be applied for and covered under a separate permit) Trim including door and window frames, windows, fascia and soffit of facade balcony, components of service wing gallery...Antique White RM, 43YY 78/053, semigloss Ironwork...Black Installation of (2) Nest Cam outdoor security cameras on the first floor Burgundy elevation. Installation of (2) white Kichler 9834 WH lights mounted to the underside of the balcony and located above each window on the first floor of the Burgundy elevation. NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 16-40572-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 30
- Expires
- Jul 12, 2017
-
Permit Renovation (Non-Structural) Other
Permit to fix Violation 16-12377-VCCNOP
- Permit
- 16-40572-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1,000
- Fees
- $98
-
Permit Dumpster/Construction Zone Other
Operate a man lift to pressure wash and paint existing single family from 10/28/2015 to 10/30/2015.
- Permit
- 15-32082-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $190
-
Permit VCC General Work Permit Finaled
Pressure wash the font of the structure at 827 Burgundy. (pressure washing must be bellow 400 PSI). Walls: Peeble Stone 759D-4 (to match existing), flat or satin finish Wooden elements including windows, frames, shop windows, fascia/soffit/outriggers of gallery: Antique White RM 43YY 78/053, semigloss. Shutters and facade entry door: Burnished Mahogany (to match existing), semigloss Ironwork: Black
- Permit
- 15-24633-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $8,000
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 17, 2016
-
Permit VCC General Work Permit Issued
Pressure wash using no greater than 500 psi the St. Ann elevations of main and service structures Replace deteriorated bricks as needed using reclaimed or soft red bricks to match existing in composition and density Tuck point masonry walls as needed using VCC approved mortar formula Hand sand all windows on the N. Rampart elevation of main structure Caulk and reglaze windows, and paint to match existing...White Re-install or replace any slipped or broken slates on roof Remove the bottom three (3) rows of slates over leak in rear wall Replace felt underlayment as necessary Install new copper flashing Re-install natural slates Mortar: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent.
- Permit
- 14-27756-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Mar 7, 2015
-
Code enforcement Case ENVHADJ-984469SN Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 25-25909-TOVR.
-
Code enforcement Case ENVHADJ-984618SN Closed
A hearing was held on 04/10/2009 with a result of "Dismissed". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Dismissed
The city links this case to permit 25-25909-TOVR.
-
Permit General Mechanical Certificate Of Completion - Issued No Meter
Warm air furnace-elec a/c 1.5 ton David A. Meyer ck#10718
- Permit
- 06MCH-10075
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $62
- Contractor
- Air-It Inc
- Days from application to issue
- 5
-
Permit General Mechanical Certificate Of Completion - Issued No Meter
Warm air furnace-elect A/C 1.5 ton David A. Meyer ck#10719
- Permit
- 06MCH-10076
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $62
- Contractor
- Air-It Inc
- Days from application to issue
- 5
-
Permit General Mechanical Application Acceptance - Approved
l.j.c. david meyey 1-a.c. split system & w.a.f.
- Permit
- 06MCH-01407
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $62
- Contractor
- Air-It Inc
- Days from application to issue
- 5
-
Permit General Mechanical Application Acceptance - Approved
l.j.c. david meyer tele. 340 8541 1-a.c. split system & 1-w.a.f.
- Permit
- 06MCH-01409
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $62
- Contractor
- Air-It Inc
- Days from application to issue
- 5
-
Permit General Mechanical Application Acceptance - Approved
l.j.c. david meyer tele. 340 8541 1-a.c. split system & w.a.f.
- Permit
- 06MCH-01410
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $62
- Contractor
- Air-It Inc
- Days from application to issue
- 5
-
Permit Electrical
GENERAL REPAIRS APARTMENT HOUSE OVILE BREAUX
- Permit
- E03001405
- Type
- Electrical
- Days from application to issue
- 0
Placed here by the building address from “827 BURGUNDY ST UNIT 4”.
-
Permit Electrical
ELECTRICAL RECONNECT APARTMENT HOUSE JOSEPH METZLER
- Permit
- E02005712
- Type
- Electrical
- Days from application to issue
- 0
Placed here by the building address from “827 BURGUNDY ST UNIT 2”.