French Quarter
937 Burgundy Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 14 permits on record here; the most recent, a change of address permit, was filed in November 2023. 3 are still open. On this block in the past year: 12 requests to 311 and 52 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 2,408 sq ft
- Parcel
- 41022566
Everything on record here
14 records, newest first · 3 open
-
Permit Change of Address Permit Issued
23-28890-RNVN Three to Four Family CHANGE 939 Burgundy St Apt 1 to 939 Burgundy St Apt 1A (AM12169503) CHANGE 939 Burgundy St Apt 2 to 939 Burgundy St Apt 2A (AM12169502) CHANGE 939 Burgundy St Apt 3 to 939 Burgundy St Apt 3A (AM12169505) CHANGE 939 Burgundy St Apt 4 to 939 Burgundy St Apt 1B (AM12169504) RETIRE 937 Burgundy St
- Permit
- 23-30341-ECOA
- Type
- Change of Address
- Work
- Change of Address
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 1
- Expires
- May 3, 2024
- Application submitted
- Permit approved
- Issue date
Placed here by an address range from “939 Burgundy St, 937 Burgundy St, 939 Burgundy St Apt 1A, 939 Burgundy St Apt 1B, 939 Burgundy St Apt 2A, 939 Burgundy St Apt 3A”.
-
Permit VCC General Work Permit Finaled
to install VCC apporved mortar cap on chimney using VCC stucco mix ***Brick chimney is not to be stuccoed in whole •Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). remove vegitation repair front door trim as necessary to match existing NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
- Permit
- 23-28890-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 7
- Expires
- Apr 27, 2024
-
Permit Renovation (Non-Structural) Other
Routine maintenance on the facade of the building.
- Permit
- 23-28890-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $4,900
- Fees
- $218
- Contractor
- Crescent City Contractors & Consultants Inc
- Days from application to issue
- 15
- Expires
- May 3, 2024
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Permit Finaled
to repair a small section of stucco on the facade of the building (to match existing) using VCC stucco mix. Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. LATH OF ANY KIND IS NOT ALLOWED. The resulting mix should range in color from off-white to beige but should not be grey in color. Note: RATIO OF PORTLAND CEMENT NOT TO EXCEED 1:12. An incorrect mortar can damage an historic building and it materials.
- Permit
- 23-22336-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- Feb 18, 2024
-
Permit Renovation (Non-Structural) In Review
We need to repair a small section of stucco on the facade of the building (to match existing).
- Permit
- 23-22336-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,400
- Fees
- $210
- Application submitted
- Zoning review
-
Permit VCC General Work Permit Finaled
Remove stringlights attached to the building Remove vegetation growing from the building Repoint masonry Retain replacement of the lower portion of the copper downspout *In response to a violation*
- Permit
- 20-29753-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 109
- Expires
- Mar 18, 2021
-
Permit Renovation (Non-Structural) Other
Correct minor maintenance issues noted by VCC letter dated 5/15/20.
- Permit
- 20-29753-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $200
- Fees
- $98
- Contractor
- Crescent City Contractors
- Application submitted
-
Permit VCC General Work Permit Finaled
Exterior repairs to correct violations cited under 16-12535-VCCNOP, per materials stamped VCC approved 05/09/18, as follows: Remove vegetation from masonry. Cut vegetation down and apply “RoundUp” or equal. Remove dead roots after 1-2 days. Install new VCC mortar (formula attached) as needed where deteriorated. Remove copper cap flashing and install convex Portland cement mortar cap with embedded aluminum mesh. Install copper cap flashing into reglet or mortar joint and seal with VCC mortar formula (attached). Remove inappropriate plywood & lowered header from Burgundy-side dormer and restore window sashes to original head location. Remove first floor sconces and repair stucco/wood trim as needed, using VCC stucco formula (attached). Paint to match existing surface. Install three (3) Remcraft 100 series to the underside of the balcony/gallery centered over the window/door openings. Fixtures shall be painted or finished to match adjacent building surface (white). All wiring shall be placed in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 600-800 lumens per bulb
- Permit
- 18-11897-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 29
- Expires
- Nov 9, 2018
-
Permit Renovation (Non-Structural) Other
Exterior repairs to correct violations in 16-12535-VCCNOP
- Permit
- 18-11897-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,500
- Fees
- $120
- Contractor
- Crescent City Contractors & Consultants Inc
- Application submitted
-
Permit VCC General Work Permit Cancelled
Retain metal cap flashing over parapet and surrounding walls Install appropriate dormer window on Burgundy elevation to match original Repair/replace two light fixtures at the front entrance. VCC staff input requested Remove vegetation per VCC method In response to a violation
- Permit
- 17-11403-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit VCC General Work Permit Issued
Remove existing roofing material Repair and/or replace underlayment as necessary Install new natural slate (grey/green), using copper nails Remove any existing galvanized gutters, flashing and vents, replace with copper gutters, flashing and vents Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles Metal cap-flashing on the parapets is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 15-11985-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Oct 27, 2015
-
Permit Renovation (Non-Structural) Permit Cancelled
Remove existing roofing material Repair and/or replace underlayment as necessary Install new natural slate (grey/green), using copper nails Remove any existing galvanized gutters, flashing and vents, replace with copper gutters, flashing and vents Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles Metal cap-flashing on the parapets is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 15-11985-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $240
-
Permit VCC Paint Permit Issued
Shutters ................ “Derby Green” (1D28C) (Gloss or semigloss) All trim including door and window frames; upper level openings; balcony soffit & fascia boards.... White
- Permit
- 14-15182-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 9
- Expires
- Nov 14, 2014
-
Permit General Mechanical Inspection - Completed
meter out over 6 months; carl ; ck#55782.
- Permit
- 10MCH-10106
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Al Bourgeois Plg&Htg
- Days from application to issue
- 5