French Quarter

509 Decatur Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 21 permits on record here. 11 are still open. There were 2 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 2 requests to 311 and 99 calls to police.

Zoning
VCC-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
3,325 sq ft
Parcel
41022633

Everything on record here

23 records, newest first · 11 open

  1. Permit Permit Permit not required

    Colossus Brass Band wedding 2nd line Saturday 11.15.25 . Formation Time 11:45am, Start time Noon.Start Location French Market Inn 509 Decatur St. End Location Lafittes Blacksmith Shop 941 Bourbon St.

    Permit
    25-34760-SPMA
    1. Application submitted
    2. Application review
  2. Permit Permit Finaled

    "FRIEDMAN SECOND LINE" second line,5/10/25 615 pm formation, 630 pm start, begins at French market inn, ends at crescent city brewhouse. ST LOUIS to BOURBON to TOULOUSE to DECATUR. 15 people.

    Permit
    25-10795-SPMA
    Days from application to issue
    120
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
  3. Permit Mechanical HVAC Application Accepted

    Using a crane remove the existing 12-Ton Mitsubishi VRF condenser and set new Mitsubishi 12-Ton VRF condenser on same stand. Reconnect existing electrical, controls, and copper piping.

    Permit
    25-10044-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $95,025
    Fees
    $72
    1. Application submitted

    See this permit on One Stop

  4. Permit Dumpster/Construction Zone Other

    Placement of dumpster for last phase of hotel room renovation - old carpeting padding, etc.

    Permit
    24-14433-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40
    Contractor
    Val Glo Construction Co

    See this permit on One Stop

  5. Permit Plumbing Permit Permit Finaled

    renovation 108 fixtures

    Permit
    23-31794-PLMB
    Type
    Plumbing Permit
    Work
    Plumbing Permit
    Estimated cost (applicant’s figure)
    $0
    Fees
    $1,080
    Contractor
    CTTraina Plbg&Htg
    Days from application to issue
    0
    Expires
    Jan 18, 2024

    See this permit on One Stop

    Placed here by an address range from “509 Decatur St, 501 Decatur St”.

  6. Permit VCC General Work Permit Cancelled

    French Market Inn Hotel / 501 Decatur St. Conversion of 36 hotel room tub/shower units into a new walk-in shower unit. Replacement of existing guest room electrical receptacles and switches. New guest room furnishings. Repainting rooms - new carpeting. No HVAC or structural elements. Tub/Shower Room Numbers / 501 Decatur Building 200-201-202-203-204-205-206-207-208-209-210-211 300-301-302-303-304-305-306-307-308-309-310-311 400-401-402-403-404-405-406-407-408-409-410-411

    Permit
    23-12780-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    14
    Expires
    Nov 26, 2023

    See this permit on One Stop

    Placed here by an address range from “509 Decatur St, 501 Decatur St”.

  7. Permit Dumpster/Construction Zone Other

    DUMPSTER location on side of hotel for interior demolition removal.

    Permit
    23-12956-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $440
    Contractor
    Val Glo Construction Co
    Days from application to issue
    5
    Expires
    Nov 16, 2023

    See this permit on One Stop

  8. Permit Renovation (Non-Structural) Permit Issued

    French Market Inn Hotel / 501 Decatur St. Conversion of 36 hotel room tub/shower units into a new walk-in shower unit. Replacement of existing guest room electrical receptacles and switches. New guest room furnishings. Repainting rooms - new carpeting. No HVAC or structural elements. Tub/Shower Room Numbers / 501 Decatur Building 200-201-202-203-204-205-206-207-208-209-210-211 300-301-302-303-304-305-306-307-308-309-310-311 400-401-402-403-404-405-406-407-408-409-410-411

    Permit
    23-12780-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $632,000
    Fees
    $5,778
    Contractor
    Val Glo Construction Co
    Days from application to issue
    39
    Expires
    Dec 19, 2023
    1. Application submitted
    2. Zoning review
    3. Application review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

    Placed here by an address range from “509 Decatur St, 501 Decatur St”.

  9. Permit VCC General Work Other

    Repair masonry at front parapet per attached materials stamped VCC approved 01/19/2023. Sound plaster and remove delaminated materials as needed. Stucco bands at parapet must be maintained in profile, size, dimension, and reveal. Mortar cap at top of parapet to be repaired as needed using Portland cement. Metal parapet caps are prohibited. Repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached). Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey in color. Paint stucco to match existing color and finish. Paint PVC pipe on roof black or gray as indicated on stamped materials to reduce visibility. NOTE: Pressure washing must not exceed 400 PSI. No metal cap flashing is permitted.

    Permit
    23-01008-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    9
    Expires
    Jul 23, 2023

    See this permit on One Stop

  10. Permit Renovation (Non-Structural) In Review

    Repair masonry at front parapet per attached materials stamped VCC approved 01/19/2023. Sound plaster and remove delaminated materials as needed. Stucco bands at parapet must be maintained in profile, size, dimension, and reveal. Mortar cap at top of parapet to be repaired as needed using Portland cement. Metal parapet caps are prohibited. Repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached). Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey in color. Paint stucco to match existing color and finish. NOTE: Pressure washing must not exceed 400 PSI. No metal cap flashing is permitted.

    Permit
    23-01008-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $8,952
    Fees
    $248
    Contractor
    R Volker Waterproofing LLC
    1. Application submitted
    2. Zoning review
    3. Application review
    4. Plan review

    See this permit on One Stop

  11. Permit VCC General Work Other

    Replace 55-ton chiller with model of similar size in same rooftop location, per attached materials stamped VCC approved 03/31/2022.

    Permit
    22-08243-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    7
    Expires
    Sep 30, 2022

    See this permit on One Stop

    Placed here by an address range from “509 Decatur St, 511 Decatur St”.

  12. Permit VCC General Work Permit Issued

    Remove existing roofing material. Repair and/or replace underlayment as necessary. Install new, natural slate roof tiles (gray or green) to match existing, using copper nails. Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed to match existing. Torch-applied roofing is not permitted. Metal cap flashing is not permitted on the parapets, chimneys or surrounding walls. Trash chutes are required from removal of debris from all roofs.

    Permit
    21-29462-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Apr 21, 2022

    See this permit on One Stop

  13. Permit Renovation (Structural) Other

    Remove the balance of the roof install new copper step flashing and counter flashing install, a 12 x 18 slate roof remove all the debris from job site

    Permit
    21-29462-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $23,000
    Fees
    $353
    1. Application submitted

    See this permit on One Stop

  14. Permit VCC General Work Permit Issued

    Work on Decatur elevation, per attached materials stamped VCC approved 04/08/2020, as follows: Remove existing fixtures and Install four (4) new "Halo ML-4" LED fixtures with "HS4R" round surface mount housing. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800 lumens per bulb. Fixtures shall be painted or prefinished to match adjacent building surface. All wiring shall be placed in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. Touch up paint on doors and windows to match existing: cream, semigloss Repair/replace deteriorated wood sills and casing on second floor doors as needed, to match existing millwork in dimension, color, size, material, detail, profile and exposure. Retain existing security cameras. Paint housing to match adjacent surface to minimize visibility. Retain "Historic French Market Inn" wood sign, measuring 3'-6" wide x 2'-10" tall

    Permit
    20-23368-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Oct 8, 2020

    See this permit on One Stop

  15. Permit Renovation (Non-Structural) Other

    Renewal of building permit 18-15039-RNVS, and VCC permit 18-33572-VCGEN. Exterior lighting modifications, exterior wood trim repair and painting, exterior sign and camera retention. Exterior work only.

    Permit
    20-23368-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $48,300
    Fees
    $458
    Contractor
    Valglo Construction Company
    Days from application to issue
    18
    Expires
    Oct 13, 2020
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  16. Permit VCC General Work Other

    Work on Decatur elevation, per attached materials stamped VCC approved 12/06/18, as follows: Remove existing fixtures and Install four (4) new "Halo ML-4" LED fixtures with "HS4R" round surface mount housing. All fixtures shall use lamps with the following criteria: 3000K color temperature, 80+ color rendering index, and 800 lumens per bulb. Fixtures shall be painted or prefinished to match adjacent building surface.All wiring shall be placed in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery/balcony purlins at the deck line, and painted to match the adjacent surfaces. Touch up paint on doors and windows to match existing: cream, semigloss Repair/replace deteriorated wood sills and casing on second floor doors as needed, to match existing millwork in dimension, color, size, material, detail, profile and exposure. Retain existing security cameras. Paint housing to match adjacent surface to minimize visibility. Retain "Historic French Market Inn" wood sign, measuring 3'-6" wide x 2'-10" tall

    Permit
    18-33572-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    50
    Expires
    Jun 6, 2019

    See this permit on One Stop

  17. Permit Renovation (Non-Structural) Other

    1. MODIFICATION OF LIGHTING UNDER SECOND FLOOR BALCONY. 2. TOUCH UP PAINT ON EXTERIOR WOOD WORK. COLOR TO MATCH EXISTING. 3. REPAIR OR REPLACE EXISTING WOOD SILLS AND CASINGS AT SECOND FLOOR DOORS AS REQUIRED. MATCH EXISTING DETAILS. 4. RETAIN EXISTING BULLET TYPE SECURITY CAMERA IF 3" MAX DIAMETER AND 8" MAX LENGTH. 5. RETAIN EXISTING HANGING BUSINESS SIGN.Sign retention shall be under separate permit.

    Permit
    18-33572-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $128
    1. Application submitted

    See this permit on One Stop

  18. Permit Electrical Repair / Replacement / Addition Permit Issued

    add 2 circuits - panel is existing

    Permit
    15-25921-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $46
    Contractor
    Elbred Malone Jr.
    Days from application to issue
    0
    Expires
    Feb 27, 2016

    See this permit on One Stop

  19. Permit Electrical Service / Circuit / Feeder Permit Issued

    RENOVATIONS- ADDING CIRCUITS- 12COM-00017

    Permit
    13-38932-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $160
    Contractor
    Steven M. Ordes
    Days from application to issue
    0
    Expires
    Mar 25, 2014

    See this permit on One Stop

  20. Permit Electrical Repair / Replacement / Addition Permit Issued

    PERMIT EXTENSION- 12COM-00017

    Permit
    12-33536-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40
    Contractor
    Steven Ordes
    Days from application to issue
    0
    Expires
    Jun 17, 2013

    See this permit on One Stop

  21. Permit Electrical Service / Circuit / Feeder Permit Issued

    Work Descripton: RENOVATIONS & LOW VOLTAGE- 12COM-00017 Historical Import Type: Permits Electrical Commercial Service-Circuits-Feeders User: DMFOLEY Tracking: 86123446457 Status: Permit Issuance Active Status Date: 3/9/2012 12:00:00 AM Owner: Decatur Hotel Corp Owner Address: Et Al 317 Magazine St, New Orleans, LA 70130 Owner Edited By: 3/9/2012 by DMFOLEY

    Permit
    12ELC-02901
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $610
    Contractor
    Ordes Electric Inc
    Days from application to issue
    0
    Expires
    Sep 9, 2012

    See this permit on One Stop

  22. Code enforcement Case ENVHADJ-941318L Closed

    The property was inspected on 05/08/1994 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 22-08243-VCGEN.

  23. Code enforcement Case ENVHADJ-962632V Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 22-08243-VCGEN.