French Quarter

715 Dauphine Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 35 permits on record here; the most recent, a VCC general work permit, was filed in October 2026. 17 are still open. On this block in the past year: 1 request to 311 and 100 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
2,404 sq ft
Parcel
41022761

Everything on record here

35 records, newest first · 17 open

  1. Permit VCC General Work Permit Issued

    To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. The resulting mix should range in color from off-white to beige but should not be grey or white in color. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Lath, mesh, or adherents of any kind are prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    26-30648-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    4
    Expires
    Apr 20, 2027
    1. Final VCC
    2. Application Submitted Complete
    3. Application Review Complete
    4. Permit Approved Complete
    5. Permit Issued Complete
    6. Vieux Carré Commission Approved

    See this permit on One Stop

  2. Permit Renovation (Structural or Non-structural) In Review

    To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS.

    Permit
    26-30648-RENO
    Type
    Renovation (Structural or Non-structural)
    Work
    Renovation (Structural or Non-structural)
    Estimated cost (applicant’s figure)
    $29,550
    Fees
    $330
    Contractor
    Stucco Paz, LLC
    1. VCC Review Unpaid
    2. Building Unpaid
    3. Building Plan Review Unpaid
    4. Application Submitted Complete
    5. Plan Review Pending
    6. Application submitted
    7. Zoning Review Complete
    8. Parks and Parkways Tree Review Complete
    9. Zoning Complete
    10. Zoning review
    11. Property Management - ROW Complete
    12. Permit Intake Under Review
    13. Plan review

    See this permit on One Stop

  3. Permit VCC Paint Permit Issued

    repair cracks in stucco using VCC stucoo formula and paint to match existing. Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. LATH OF ANY KIND IS NOT ALLOWED.

    Permit
    26-16137-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    3
    Expires
    Dec 1, 2026

    See this permit on One Stop

  4. Permit VCC Paint Permit Issued

    ALL PAINT COLORS TO MATCH EXISTING reglaze windows where necessary reinstall missing ironwork, to match.

    Permit
    25-08517-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    Raymond W Hostetter
    Days from application to issue
    0
    Expires
    Sep 18, 2025

    See this permit on One Stop

  5. Permit VCC General Work Permit Cancelled

    Paint all Iron Work Black to match existing. Repair Iron work as needed.

    Permit
    25-08389-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  6. Permit Renovation (Non-Structural) Permit Cancelled

    Paint all Iron Work Black to match existing. Repair Iron work as needed.

    Permit
    25-08389-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $20,000
    Fees
    $220
    Contractor
    Raymond W Hostetter
    1. Application submitted

    See this permit on One Stop

  7. Permit VCC General Work Permit Issued

    To repair stucco on the Orleans and St. Peter elevations as per materials stamped VCC approved 03/02/2022. All repair work to match existing including finish, paint, and scoring pattern.

    Permit
    22-03279-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Sep 2, 2022

    See this permit on One Stop

  8. Permit Renovation (Non-Structural) In Review

    Repair cracks and damaged stucco on west/ southwest wall, as well as around garage door on Orleans st as needed. All repairs to be painted to match existing colors.

    Permit
    22-03279-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $17,525
    Fees
    $225
    Contractor
    Jose A Paz
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  9. Permit VCC General Work Other

    To replace roofs of both the main building and the rear service building as per materials stamped VCC approved 03/04/2021. Work includes: • Remove existing roofing materials • Repair and/or replace underlayment as necessary • Install new 12” x 18” natural slate (grey/green), using copper nails • Install/repair copper flashing • Reinstall terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.

    Permit
    21-03689-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    265
    Expires
    May 1, 2022

    See this permit on One Stop

  10. Permit Renovation (Structural) Other

    Replace existing roof with new slate roof covering

    Permit
    21-03689-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $37,493
    Fees
    $375
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved

    See this permit on One Stop

  11. Permit VCC Paint Other

    ironwork: black, semigloss (to match existing) gallery: extra white, semigloss (to match existing)

    Permit
    20-29041-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 22, 2020

    See this permit on One Stop

  12. Permit VCC General Work Permit Cancelled

    -Remove existing cracked/broken shingles, and hip/ridge caps from bottom of rear hip, right side. Hip and ridge caps to be salvaged for reinstallation. -Nail one (1) layer of 30# felt underlay over wood decking. -Install shingles to match existing shingles in type, size and profile on each side of hip ridge to match existing conditions. -Reinstall existing hip and ridge caps.

    Permit
    19-38272-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    Jun 11, 2020

    See this permit on One Stop

  13. Permit Renovation (Non-Structural) Other

    Replace damaged slate roof tiles as needed to match existing

    Permit
    19-38272-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,000
    Fees
    $98
    1. Application submitted

    See this permit on One Stop

  14. Permit VCC General Work Permit Finaled

    To remove vegetation from Burgundy elevation of main building and from gallery ironwork as follows: • Cutting plants at ground level and/or spraying with herbicide • Allowing plants to wilt for a minimum of three days prior to attempting to remove If additional repair work is needed following plant removal applicant to submit for separate permit. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. can close 3/11/2020

    Permit
    19-36410-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    May 13, 2020

    See this permit on One Stop

  15. Permit VCC General Work In Review

    Permission to remove wisteria growing from the courtyard onto the gallery, replace wrought iron and touch up paint in existing colors as needed. Request to retain fig ivy presently growing on the Burgundy/St.Ann elevation walls (see photo). All in response to VCC violation case 18-07089-DBNVCC

    Permit
    19-09405-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  16. Permit Renovation (Non-Structural) Other

    Permission to remove wisteria growing from the courtyard onto the gallery, replace wrought iron and touch up paint in existing colors as needed. Request to retain fig ivy presently growing on the Burgundy/St.Ann elevation walls (see photo). All in response to VCC violation case 18-07089-DBNVCC

    Permit
    19-09405-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,500
    Fees
    $105
    1. Application submitted

    See this permit on One Stop

  17. Permit VCC General Work Permit Cancelled

    replace or repair damaged slate shingles on main roof. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    18-30771-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    1
    Expires
    Mar 21, 2019

    See this permit on One Stop

  18. Permit Renovation (Non-Structural) Application Accepted

    A few slate shingles have fallen in the courtyard, after evaluation by a licensed roofer there are several that are loose or missing. Scope of renovation is to replace or repair missing or damaged slate shingles to match existing roof.

    Permit
    18-30771-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $871
    Fees
    $98
    1. Application submitted

    See this permit on One Stop

  19. Permit VCC General Work Permit Finaled

    remove vegitaiton from courtyard wall, windows, shutters and from gutters along the gallery To repoint masonry utilizing mortar mix and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. repait where needed using existing colors All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.

    Permit
    18-27922-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Feb 27, 2019

    See this permit on One Stop

  20. Permit Renovation (Non-Structural) Other

    Permit to cover removal of vines from courtyard wall, windows, shutters and along gutters as well as gallery, repair mortar as needed using VCC approved mortar mix and to repaint as needed to match existing colors.

    Permit
    18-27922-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $2,000
    Fees
    $105
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved

    See this permit on One Stop

  21. Permit VCC Paint Permit Cancelled

    Wood rail: black (to match existing), semigloss Gallery decking: light gray (to match existing), semigloss

    Permit
    17-02735-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    1
    Expires
    Jul 26, 2017

    See this permit on One Stop

  22. Permit VCC General Work Permit Finaled

    To repair/replace two gallery columns damaged by auto accident. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.

    Permit
    16-38908-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    May 30, 2017

    See this permit on One Stop

  23. Permit Renovation (Non-Structural) Other

    replace 2 iron gallery support posts

    Permit
    16-38908-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $3,200
    Fees
    $120

    See this permit on One Stop

  24. Permit VCC General Work Permit Issued

    All repair/replacement work shall match existing in color, size, material, detail, profile and exposure Repair and repaint damaged stucco, to match existing, flat or satin finish Repair concrete gallery bases, Repair louvered shutters as needed. To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows: Prep and paint underside of gallery and outriggers: white, semigloss Prep and paint gallery poles: black. This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastomeric coatings/paints, waterproofing/water repellent coatings.

    Permit
    15-15128-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 19, 2015

    See this permit on One Stop

  25. Permit VCC General Work Permit Finaled

    Remove deteriorated garage door on Orleans side of service wing, Install new pre-primed, treated plywood garage door, to match existing, per Architectural Committee approval 12/22/15 and VCC approval 01/07/16. Install new motor and wheels, existing tracks to remain, Paint all sides and edges of garage door to match existing, Repair, prime and paint stucco to match existing per VCC stucco formula: Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part Portland Cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: No more than 1 Part Portland cement, 3 Parts Lime, 9 Parts Sand, Enough water to form a workable mix. The resulting mix should range in color from white to beige but should not be grey in color. Note: RATIO OF PORTLAND CEMENT NOT TO EXCEED 1:12.

    Permit
    15-08672-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $2,000
    Fees
    $0
    Days from application to issue
    291
    Expires
    Jul 8, 2016

    See this permit on One Stop

  26. Permit VCC Paint Permit Issued

    Remove deteriorated fascia install new Spanish cedar fascia, 6" in height to match existing Paint...White

    Permit
    14-25435-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    1
    Expires
    Feb 14, 2015

    See this permit on One Stop

  27. Permit VCC General Work Permit Finaled

    retain NOPD security camera, per AC & VCC approval 4/22/14 & 5/7/14, and stamped approved 5/8/14. This permit addresses the same cameras approved by Permit No. 090140: • Per Vieux Carré Commission approval (February 17, 2009) to retain the SpeedDome Ultra 8 Camera Dome (approximately 8” in diameter and 8” long), extending about 15” out from the 2nd floor gallery at the corner of Dauphine and Orleans Street. • Per the VCC approval, the applicant must return in five (5) years, i.e., February 2014, for re-approval by the VCC

    Permit
    14-14598-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    43
    Expires
    Nov 8, 2014

    See this permit on One Stop

  28. Permit VCC Paint Other

    Historical Import Type: Enforcement VCC Permit Paint User: RPELL Tracking: 86162714817 Status: Permit Issued Status Date: 1/27/2012 12:00:00 AM Owner: 715 Dauphine St La, LLC Owner Address: 16885 Dallas Pkwy, Addison, TX 75001 Owner Edited By: 1/27/2012 by RPELL To prepare for painting by washing using a low water pressure; sanding (rotary sanders cannot be used); making minor millwork and/or masonry repairs as necessary to match existing conditions (masonry mix must be soft with portland cement content not to exceed 1 part to 12); and to paint as follows: • Wooden elements including doors, White to match existing, semigloss • Shutters, French Quarter Green to amtch existing, semigloss

    Permit
    VCCP-12-0066
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
  29. Permit Renovation (Non-Structural) Certificate of Occupancy - Issued No Meter

    RENOVATE KITCHEN BY REMOVING CABINETS, CONSTRUCTION OF CUSTOM CABINETS AND INSTALLING SAME. WORK IS FOR 900 ORLEANS.

    Permit
    07BLD-10226
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,000
    Fees
    $85
    Days from application to issue
    5
  30. Permit Renovation (Non-Structural) Certificate of Occupancy - Issued No Meter

    INSTALLATION OF WOOD FLOORING TO MATCH EXISTING PINE FLOOR APPROXIMATELY 16'X16'. WORK TO BE PERFORMED AT 900 ORLEANS.

    Permit
    07BLD-10227
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $75
    Days from application to issue
    5
  31. Permit General Mechanical Inspection - Completed

    INSTALL NEW CONDENSER UNITS (5-TON & (2) 2-TON) OCTAVE PEPPO (#258)

    Permit
    07MCH-13904
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $72
    Contractor
    Prppo Brothers
    Days from application to issue
    5
  32. Permit General Mechanical Inspection - Completed

    INstall 3-ton condenser. Octave Peppo (#258)

    Permit
    07MCH-13906
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $42
    Contractor
    Prppo Brothers
    Days from application to issue
    5
  33. Permit Renovation (Non-Structural) Application Acceptance - Approved No Review

    Interior ONLY Minor drywall repair, painting, and wall paper.

    Permit
    07BLD-08130
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $15,000
    Fees
    $75
    Days from application to issue
    5
  34. Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved

    EMERGENCY RECONNECT

    Permit
    07ELC-20970
    Type
    Electrical Repair / Replacement / Addition
    Work
    Repair-Replacement-Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    C. J's Electric LLC.
    Days from application to issue
    10
  35. Permit Electrical

    EMERGENCY RECONNECT

    Permit
    07ELC-20971
    Type
    Electrical
    Work
    Repair-Replacement-Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30