French Quarter
617 Dumaine Street is in French Quarter, zoned VCR-2 (French Quarter residential, with somewhat higher density than VCR-1). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 8 permits on record here; the most recent, a VCC general work permit, was filed in June 2025. 3 are still open. On this block in the past year: 5 requests to 311 and 18 calls to police.
- Zoning
- VCR-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 5,612 sq ft
- Parcel
- 41022876
Everything on record here
8 records, newest first · 3 open
-
Permit VCC General Work Other
To replace roofs of rear and side buildings as per materials stamped VCC approved 07/01/2025. Work includes: • Remove existing slate roofing material • Repair and/or replace underlayment as necessary • Install new ¬¬¬18” x 12” natural slate (Royal Purple – to match existing), using copper nails • Install/repair half round copper gutters and flashing • Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Replace roofing of small flat roof with new grey TPO roofing • Metal cap-flashing on the parapets or chimneys is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 25-18064-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 15
- Expires
- Jan 1, 2026
-
Permit Residential Re-Roofing Permit Issued
Slate Roof Replacement Manufacturer- Camaro slate products VT Brand/Grade- ASTM grade A Color- Vermont Royal Purple Tear Off- YES Underlayment- High Temp Ice and Water Shield Valley- Copper Valleys Ventilation- Replace Lourve Vents (Copper) Turtle Vent- Replace with Copper Drip Edge- Copper Drip Edge Heat Stacks- 3 piece 1 piece Pipe Boots- Replace Chimney Flashing- Replace/Copper Installation Method- Handnail 68 PCs. 12’ x 9 1/2” x 7/8” for decking One Beam 28’ x 7” x 4” Replace chimney flashing on (4) Chimneys, (3) half chimneys and (1) dormer flashing: Copper. Flat Roof Replacement (on rear on building where mechanical sits) -Remove existing flat roof -Replace wall flashings and install 60 mil TPO fully adhered -remove and replace 2 skylights
- Permit
- 25-18064-ROOF
- Type
- Residential Re-Roofing
- Work
- Residential Re-Roofing
- Estimated cost (applicant’s figure)
- $0
- Fees
- $90
- Contractor
- Parish Construction and Roofin
- Days from application to issue
- 28
- Expires
- Jan 10, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Electrical Service / Circuit / Feeder Other
Install 70 amp disconnect
- Permit
- 22-01418-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $88
- Contractor
- Timothy Jason Carman
- Application submitted
- Application review
- Permit approved
Placed here by its map location from “621 Dumaine St”.
-
Permit Small Cell Installation Other
Multi-Carrier Small Cell Installation – Replace Existing Lamp Post
- Permit
- 21-14402-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $2,500
- Days from application to issue
- 80
- Expires
- Feb 6, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
Placed here by its map location from “621 Dumaine St”.
-
Permit VCC General Work Permit Issued
To repair/replace existing slate roof with new slate tiles matched to the existing To repair/replace flashing and flashing cement located adjacent to the parapet on the rear roof slope of the rear building To remove vegetation from the Royal St. elevation of the main roof Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 17-13810-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 6
- Expires
- Nov 1, 2017
-
Permit Renovation (Non-Structural) Other
Misc. roof repairs.
- Permit
- 17-13810-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $4,210
- Fees
- $128
- Contractor
- Robertson Roofing and Siding Inc
-
Permit VCC Paint Permit Issued
Gates: BM black forest green (to match existing), semigloss Shutters: Bm black forest green (to match existing), semigloss
- Permit
- 17-05540-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Aug 15, 2017
-
Permit VCC General Work Permit Issued
Remove and replace forest green and natural white 6-bar sunbrella canvas (SB-4806) to match existing, per application and materials received 03/13/15.
- Permit
- 15-07920-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $6,934
- Fees
- $0
- Days from application to issue
- 4
- Expires
- Sep 27, 2015