French Quarter

817 Dumaine Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 10 permits on record here; the most recent, a VCC general work permit, was filed in August 2026. 7 are still open. On this block in the past year: 10 requests to 311 and 24 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
4,240 sq ft
Parcel
41022897

Everything on record here

10 records, newest first · 7 open

  1. Permit VCC General Work Permit Issued

    ALL REPAIR WORK IS TO MATCH EXISITNG SLATE IT TO MATCH EXISTING SLATE IN SIZE, SHAPE AND COLOR Remove the necessary slate around the base of the chimney. Remove the existing flashing. Install a water barrier membrane and new 16 ounce copper flashings. Install felt and new slate where removed, Clean all gutters on entire house; bag and dispose of debris associated with this cleaning, Install a new slate where missing on the side of the dormer near the chimney, IF NEEDED Remove the necessary slate along the wall. Remove the existing flashing. Install a water barrier membrane and new 16 ounce copper flashings. Install felt and new slate where removed.

    Permit
    26-22713-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    3
    Expires
    Feb 6, 2027
    1. Final VCC
    2. Application Submitted Complete
    3. Application Review Complete
    4. Permit Approved Complete
    5. Permit Issued Complete
    6. Vieux Carré Commission Complete

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Permit Issued

    ALL REPAIR WORK IS TO MATCH EXISITNG SLATE IT TO MATCH EXISTING SLATE IN SIZE, SHAPE AND COLOR Remove the necessary slate around the base of the chimney. Remove the existing flashing. Install a water barrier membrane and new 16 ounce copper flashings. Install felt and new slate where removed, Clean all gutters on entire house; bag and dispose of debris associated with this cleaning, Install a new slate where missing on the side of the dormer near the chimney, IF NEEDED Remove the necessary slate along the wall. Remove the existing flashing. Install a water barrier membrane and new 16 ounce copper flashings. Install felt and new slate where removed

    Permit
    26-22713-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $3,275
    Fees
    $360
    Contractor
    Robertson Roofing and Siding Inc
    Days from application to issue
    37
    Expires
    Mar 9, 2027
    1. Building Permit - Application Filing Fee Paid
    2. VCC Review Paid
    3. Building Paid
    4. Building Plan Review Paid
    5. Residential Final C/O Inspection
    6. Residential Final C/O Documents
    7. Rough Framing
    8. Application Submitted Complete
    9. Zoning Complete
    10. Application submitted
    11. Application Review Complete
    12. Permit Intake Complete
    13. Orleans Levee District Review not Required
    14. Application review
    15. Zoning Review Complete
    16. Plan Review Complete
    17. Permit Approved Complete
    18. Sub-Permits Issued Complete
    19. Plan Review Complete
    20. Zoning review
    21. Plan review
    22. Permit approved
    23. Permit Issued Complete
    24. Issue date

    See this permit on One Stop

  3. Permit VCC General Work Permit Issued

    to install mortar cap on chimney top using VCC approved mortar and stucco mix and detial sheet Permit does not allow for cap flashing on parapets, chimneys or surrounding walls apply VCC approved mortar mix to cracksa nd openings in brick wall on the back side of the chimney above compromised area fabricate and install 2 small 16 ounce copper flashings to direct the water from teh chimney cap away from the chimney Mortar: No more than: • 1 part Portland Cement, to • 3 parts lime, • 9 parts sand, and • enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. The resulting mortar should range in color from white to beige but should not be grey in color. When repointing, all mortar to be tooled to match existing joint profiles. Consult with VCC staff if existing joint profile indeterminate. Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. LATH OF ANY KIND IS NOT ALLOWED.

    Permit
    24-33410-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    May 1, 2025

    See this permit on One Stop

  4. Permit Renovation (Non-Structural) Other

    ROOF REPAIRS - ROOFS DAMAGED FROM FRANCINE STORM - JUST REPAIRING BROKEN/LEAKING SPOTS

    Permit
    24-33410-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $6,510
    Fees
    $233
    Contractor
    Robertson Roofing and Siding, Inc, Robertson Roofing and Siding Inc
    1. Application submitted
    2. Zoning review

    See this permit on One Stop

  5. Permit VCC Paint In Review

    Paint HVAC platform to match existing. May also include some replacement of equipment.

    Permit
    24-08606-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    French Quarter Renovations, LLC

    See this permit on One Stop

  6. Permit Dumpster/Construction Zone Other

    Reserved parking space for moving trucks.

    Permit
    23-32031-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
    Days from application to issue
    11
    Expires
    Jun 8, 2024

    See this permit on One Stop

  7. Permit Dumpster/Construction Zone Other

    Parking reserved for moving vehicles associated with 817 Dumaine St.

    Permit
    23-31731-RCZD
    Type
    Dumpster/Construction Zone
    Work
    Dumpster/Construction Zone
    Estimated cost (applicant’s figure)
    $0
    Fees
    $190
    Days from application to issue
    10
    Expires
    May 27, 2024

    See this permit on One Stop

  8. Permit VCC Paint Permit Issued

    ***ALL COLORS TO MATCH EXISITNG to repair any deteroiate wood where necessary, all work to match existing is material, size, shape and profile

    Permit
    23-09482-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    8
    Expires
    Oct 19, 2023

    See this permit on One Stop

  9. Permit VCC Paint Permit Issued

    all work on the river side wall of the main building To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property.

    Permit
    20-49221-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Contractor
    John Crouch FQR LLC
    Days from application to issue
    2
    Expires
    Jun 13, 2021

    See this permit on One Stop

  10. Permit General Mechanical Inspection - Completed

    #076137 Katrina

    Permit
    05MCH-06424
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    C.N.Finley Inc
    Days from application to issue
    5