French Quarter
830 North Rampart Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 10 permits on record here; the most recent, a VCC general work permit, was filed in May 2022. 8 are still open. On this block in the past year: 10 requests to 311 and 149 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 3,197 sq ft
- Parcel
- 41022946
Everything on record here
10 records, newest first · 8 open
-
Permit VCC General Work Permit Issued
Remove existing roofing material Repair and/or replace underlayment as necessary Install new natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 22-14037-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 1
- Expires
- Nov 17, 2022
-
Permit Renovation (Non-Structural) Permit Issued
Install new slate roof
- Permit
- 22-14037-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $38,500
- Fees
- $473
- Days from application to issue
- 93
- Expires
- Feb 11, 2023
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Application Accepted
Replace existing plate glass picture window with floor to ceiling opening with French doors and shutters.
- Permit
- 21-16147-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Structural) Other
Replace existing plate glass picture window with floor to ceiling opening with French doors and shutters.
- Permit
- 21-16147-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $180
- Application submitted
-
Permit VCC Paint Other
To repair minor crack in the stucco in preparation for painting. To repoint masonry utilizing mortar mixed and applied per the VCC standard detail sheet (attached) Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property.
- Permit
- 19-27913-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Kendall Ward
- Days from application to issue
- 0
- Expires
- Mar 4, 2020
-
Permit VCC General Work Permit Issued
To install a condenser unit (3 ton Goodman unit) at ground level on a concrete pad in the rear courtyard, per attached survey of property. The unit will measure 24” high x 28” wide x 26” deep To reinstall the existing light fixtures
- Permit
- 12-20028-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jan 25, 2013
-
Permit Electrical Service / Circuit / Feeder Permit Issued
Work Descripton: REWIRE- 12BLD-01628 Historical Import Type: Permits Electrical Residential Service-Circuits-Feeders User: DMFOLEY Tracking: 86142182817 Status: Permit Issuance Active Status Date: 5/16/2012 12:00:00 AM Owner: Watermeier Leo A Owner Address: 812 N Rampart St, New Orleans, LA 70116 Owner Edited By: 5/16/2012 by DMFOLEY
- Permit
- 12ELC-05533
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $126
- Contractor
- Champ Electric
- Days from application to issue
- 0
- Expires
- Nov 16, 2012
-
Permit General Mechanical Other
Work Descripton: INSTALL GAS WAF, GAS LINE, METER OUT OVER 6 MOS. AND A/C. SAM SIMONTON (#1164) 12BLD-01628 Waiting on A/C Historical Import Type: Permits Mechanical Residential General Mechanical User: JOSLEE Tracking: 86128586571 Status: Meter Release Pending Status Date: 6/6/2012 12:00:00 AM Owner: Leo Watermeier Owner Address: 832 N Rampart St, New Orleans, LA 70116 Owner Edited By: 5/15/2012 by JOSLEE
- Permit
- 12MCH-03737
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $115
- Contractor
- Sam's Refrigeration
- Days from application to issue
- 0
- Expires
- Nov 15, 2012
-
Permit Renovation (Non-Structural) Occupancy
Work Descripton: NON-STRUCTURAL SUPPLEMENTAL PERMIT TO INCREASE SCOPE AND VALUE OF WORK. REPAIRS INCLUDE ELECTRICAL, PLUMBING, SHEETROCK, PAINTING. NO EXTERIOR WORK ALLOWED UNDER THIS PERMIT. Historical Import Type: Permits Residential Single (One-Family Unit) Renovation (Non-Structural) User: CCROSS Tracking: 86133972865 Status: Permit Issuance Active Status Date: 3/15/2012 12:00:00 AM Owner: Leo Watermeier Owner Address: 812 N Rampart St, New Orleans, LA 70116 Owner Edited By: 3/15/2012 by CCROSS
- Permit
- 12BLD-01628
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $30,000
- Fees
- $400
- Days from application to issue
- 0
- Expires
- Sep 15, 2012
Placed here by a known alternate street name from “832 N Rampart”.
-
Permit Renovation (Non-Structural) Application Acceptance - Approved No Review
REPAIR INTERIOR TERMITE DAMAGE. NO EXTERIOR WORK UNDER THIS PERMIT.
- Permit
- 10BLD-04864
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $15,000
- Fees
- $135
- Days from application to issue
- 5