French Quarter
637 Burgundy Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 10 permits on record here; the most recent, a VCC general work permit, was filed in February 2025. 4 are still open. On this block in the past year: 2 requests to 311 and 15 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 3,271 sq ft
- Parcel
- 41022978
Everything on record here
10 records, newest first · 4 open
-
Permit VCC General Work Permit Issued
To install new keypad gate hardware as per Architecture Committee approval of 03/25/2025 and materials stamped VCC approved 03/27/2025. 04/02/2025 - NOTE: Applicant informed staff that the new keypad lock did not function as inspected and elected to install a typical deadbolt lock.
- Permit
- 25-05179-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 36
- Expires
- Sep 27, 2025
-
Permit Renovation (Non-Structural) Permit Cancelled
Exterior lock change
- Permit
- 25-05179-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $80
- Fees
- $125
- Application submitted
- Zoning review
-
Permit VCC General Work Permit Finaled
Remove existing roofing material Repair and/or replace underlayment as necessary Install new 12” x 18” natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 22-30722-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 11
- Expires
- Apr 25, 2023
-
Permit Renovation (Non-Structural) Permit Issued
Roof Replacement (See Attached Scope of work)
- Permit
- 22-30722-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $51,500
- Fees
- $570
- Contractor
- Construction Specialist Group LLC
- Days from application to issue
- 22
- Expires
- May 2, 2023
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit VCC General Work Permit Finaled
To repair roof including the following work: • Replace missing/broken Eternit/Maxi slate throughout the roof with matching materials. • Remove roof cement from base of chimneys and install mortar skim coat, remove aluminum flashing at side of chimney. • Fabricate and install new copper flashing at the base of one chimney. • Fabricate and install copper counter flashing at the base of all chimneys. • Remove existing V-Tile that have been coated with roofing cement. • Furnish and install new terra cotta V-Tile in mortar bed. • Apply new grey aluminum coating to metal roof. (Coating to be non-reflective) All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.
- Permit
- 19-30368-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Mar 25, 2020
-
Permit VCC General Work Other
Repair and replace broken slate roof tiles to match existing. Replace broken ridge tiles with matching tiles. Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. Failure to exactly match materials, details, profiles, exposures, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work.
- Permit
- 19-22457-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jan 17, 2020
-
Permit VCC General Work Permit Finaled
To install two (2) new copper awnings on the N. Rampart elevation of the main building as per Architecture Committee approval of 07/16/19 and materials stamped VCC approved 08/08/19. Awnings to be made of copper with a simple straight valence. To relocate existing French doors on the N. Rampart elevation of the main building to the interior side of the jamb. *can't get access to see new french door location 2020.02.04*
- Permit
- 19-20029-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 45
- Expires
- Feb 8, 2020
-
Permit Renovation (Non-Structural) Other
Replacement of decayed existing non-historic trim and non-historic sills on two french doors and metal awning installation.
- Permit
- 19-20029-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $9,944
- Fees
- $165
- Contractor
- Supreme Commercial Contracting LLC
- Days from application to issue
- 88
- Expires
- Mar 17, 2020
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Dumpster/Construction Zone Other
Entergy needs to remove a transformer from a vault in the street. this will take about 3 to four hours from 12:00 PM to 4:00 PM.
- Permit
- 19-07253-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $375
-
Permit Renovation (Structural) Application Acceptance - Approved No Review
INSTALL GATE TO EXISTING MULTI-FAMILY DWELLING AS PLER VCC #080365 AND SKETCH.
- Permit
- 08COM-01057
- Type
- Renovation (Structural)
- Work
- NA
- Estimated cost (applicant’s figure)
- $5,300
- Fees
- $120
- Days from application to issue
- 5