French Quarter
335 Dauphine Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 28 permits on record here; the most recent, a street cut permit, was filed in May 2026. 17 are still open. There were 3 past code enforcement cases, the latest in January 2010, all closed. On this block in the past year: 1 request to 311 and 112 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 4
- Lot size
- 6,404 sq ft
- Parcel
- 41023133
Everything on record here
31 records, newest first · 17 open
-
Permit Street Cut Permit Issued
4x4 sidewalk cut. DOES NOT COVER SMALL CELLL INSTALLATION.
- Permit
- 26-14561-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $112
- Days from application to issue
- 37
- Expires
- Dec 19, 2026
Placed here by its tax bill number from “355 Dauphine St”.
-
Permit VCC General Work In Review
Reinstall eyebrow windows at the 3rd floor previously removed by the tenant for a window unit AC. No new windows to be fabricated, existing to be reinstalled
- Permit
- 25-39853-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Reinstall eyebrow windows at the 3rd floor previously removed by the tenant for a window unit AC. No new windows to be fabricated, existing to be reinstalled
- Permit
- 25-39853-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $120
- Contractor
- Werling Builders, Inc
- Application submitted
-
Permit VCC General Work In Review
For Vieux Carre' Commission Conceptual Review
- Permit
- 25-39221-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Structural) Application Accepted
For Vieux Carre' Commission Conceptual Review
- Permit
- 25-39221-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $0
- Fees
- $180
- Contractor
- Werling Builders, Inc
- Application submitted
-
Permit VCC General Work In Review
To repair/replace install wood eyebrow windows, chimney, and courtyard wall stucco as per materials stamped VCC approved 05/30/2023. Work includes: • Installation of new wood windows in eyebrow window locations to match existing • Repair/replacement of one existing damaged chimney to match existing adjacent chimneys • Removal of loose/failing stucco from the Conti elevation of the courtyard wall. Brick to be left exposed for no more than two weeks. • Application of new stucco as per VCC standard details NOTE: Permit issued in response to violations. Work shall commence within 30 days from the date of permit issuance. Work must be completed no more than 60 days after work begins. Owner will call VCC for final inspection upon completion of work. Penalty fees may apply because of improper or unauthorized work.
- Permit
- 23-11895-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 27
- Expires
- Nov 30, 2023
-
Permit Renovation (Non-Structural) In Review
Repair/Replace Chimneys damaged by lightning, during the installation of the new roof per roof permit 22-28832-VCGEN. Use 9-3-1 mixture of sand-hydrated lime-portland cement for the mortar in the bricks. Re-use salvaged bricks from the old chimneys. Repair/Replace eyebrow windows previously approved in permit 16-35342-VCGEN.
- Permit
- 23-11895-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $6,000
- Fees
- $225
- Contractor
- Werling Builders, Inc
- Application submitted
- Zoning review
-
Permit VCC General Work Other
To remove two fire escapes from the Burgundy elevation of the main building as per materials stamped VCC approved 04/12/2023. Work includes: • Repairs to damage to masonry from fire escape mounting points to match existing masonry • Installation of balcony railing to match existing adjacent balcony railing
- Permit
- 23-07791-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 21
- Expires
- Oct 12, 2023
-
Permit Renovation (Non-Structural) In Review
Remove old fire escape and "bridge" from the rear of the building to the service building. See attached photo for clarification.
- Permit
- 23-07791-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $7,122
- Fees
- $240
- Contractor
- Werling Builders,Inc
- Application submitted
- Zoning review
-
Permit Dumpster/Construction Zone Other
Remove slate roof and repair/replace the slate. The sidewalk and the parking area is needed to protect the public and stage the trucks and trailers.
- Permit
- 22-32301-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $315
- Contractor
- Werling Builders, Inc
-
Permit VCC General Work Permit Issued
***Roof originally submitted under permit 22-06706. Remove existing roofing material Repair and/or replace underlayment as necessary Install new 10” x 16” natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure. NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work
- Permit
- 22-28832-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Mar 23, 2023
-
Permit Electrical Service / Circuit / Feeder Other
Install 60AMP disconnect on Verizon Small Cell Pole
- Permit
- 22-21609-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,400
- Fees
- $67
- Contractor
- Brandon Michael Descant
- Application submitted
- Application review
- Permit approved
Placed here by its map location from “910 Conti St”.
-
Permit VCC General Work Other
Remove and replace slate roofs per the attached designs using approved gray/green slate, copper connectors, and copper flashings. Rebuild rear fences per the attached designs previously approved by the architectural committee of the Vieux Carre' Commission. Repair balcony handrails and spindles utilizing the standard details found in the Vieux Carre' Commission's information. Remove vegetation where applicable, see attached. Replace slate chimney caps where missing. Rebuild chimneys that were previously damaged in weather events utilizing old red bricks and a mortar recipe of 9-3-1 as approved by the Vieux Carre' Commission. Inspect and repair window lintel and stucco shown in the attachment. Replace the entry door with a 6 panel wood door. Inspect and repair cracks in the brick fence. Remove old aluminum fascia covering and paint fascia to match existing trim, see attached. Install previously approved windows which have been fabricated and are on site.
- Permit
- 22-06706-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) In Review
Remove and replace slate roofs per the attached designs using approved gray/green slate, copper connectors, and copper flashings. Rebuild rear fences per the attached. Repair balcony handrails and spindles utilizing the standard details found in the Vieux Carre' Commission's information, the guards to be at least 42" high. Remove vegetation where applicable, see attached. Replace slate chimney caps where missing. Rebuild chimneys that were previously damaged in weather events utilizing old red bricks and a mortar recipe of 9-3-1 as approved by the Vieux Carre' Commission. Inspect and repair window lintel and stucco shown in the attachment. Replace the entry door with a 6 panel wood door. Inspect and repair cracks in the brick fence. Remove old aluminum fascia covering and paint fascia to match existing trim, see attached. Install previously approved windows which have been fabricated and are on site.
- Permit
- 22-06706-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $96,000
- Fees
- $810
- Contractor
- Werling Builders,Inc
- Application submitted
- Zoning review
-
Permit Small Cell Installation Other
Verizon is proposing to install a small cell antenna on an existing Toro Street light pole. 20' pole to be painted by pole manufacturer. 3-5G radios mounted at 17.15' Rad Center. Non Metered pole with power delivered via underground. Fiber delivered via underground by others. Replace pole/ transfer existing signage
- Permit
- 20-34709-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $2,500
- Days from application to issue
- 469
- Expires
- Apr 28, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
Placed here by its map location from “910 Conti St”.
-
Permit Street Cut Other
Remove and Replace Existing equipment Node with upgraded equipmet
- Permit
- 20-29802-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $292
- Days from application to issue
- 7
- Expires
- Dec 5, 2020
-
Permit Dumpster/Construction Zone Other
Lane closure for City Project.
- Permit
- 17-35560-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Apr 17, 2018
-
Permit Dumpster/Construction Zone Other
Install a construction zone for 90 days, 08/01/17 to 10/29/2017 w/ scaffolding to necessary mill work repairs and paint facade. Sidewalk closure on Dauphine St with a pedestrian passage through parking lane. Related permit 16- 35342- VCGEN.
- Permit
- 17-25667-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $375
- Contractor
- Werling Builders Inc
- Days from application to issue
- 0
- Expires
- Jan 25, 2018
-
Permit VCC General Work Permit Cancelled
To renovate building as per Architectural Committee approval of 05/09/17 and final plans stamped VCC approved 06/02/17. Work includes but is not limited to: • Demolition of existing wood fencing along the Burgundy St. property line • Construction of new 10’ tall seven board style wood fence with wood gates, constructed as per gate no. 2 on VCC standard detail sheet 17, along the Burgundy St. property line in same location as previously existing fence • Repair/restoration of all existing windows throughout property, including windows currently boarded over, to match existing • Repair as needed all millwork at the third floor level just below the roof line and eyebrow windows • Remove any identifiable unused wires on the facade of the building. Place in conduits and organize in an orderly fashion, any needed wires and paint to match the adjacent building surface • Remove the fluorescent light fixture under the canopy • Replace/Repair stucco on the back portion of the main house as per VCC standard detail sheet (attached) • Remove any vegetation on the building facade, treat the area and tuck point, if necessary, using the VCC standard detail sheet (attached) To prepare for painting by washing using a low water pressure (400 psi max); sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follo
- Permit
- 16-35342-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 219
- Expires
- Dec 8, 2017
-
Permit Renovation (Non-Structural) Other
Repair millwork at 3rd level; remove light fixture under canopy and replace with an approved fixture; Replace/Repair stucco; new 7 board fences; remove vegetation from facade, tuck point, if necessary; paint
- Permit
- 16-35342-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $12,875
- Fees
- $188
- Contractor
- Werling Builders Inc
-
Permit Accessory Structure Application Accepted
replace old awning with new one. Same color, same shape and size. Would like to change the scalloped bottom to a straight hem because it does not ravel.
- Permit
- 15-30413-ACCS
- Type
- Accessory Structure
- Work
- Accessory Structure
- Estimated cost (applicant’s figure)
- $0
- Fees
- $60
-
Permit VCC General Work Permit Cancelled
Remove existing deteriorated, scalloped-hem, three-sided canvas, Install new Sunbrella 6431- Burgundy straight-hem canvas; single slope with open sides "California-style" awning, per drawing stamped VCC approved 11/13/15.. Awning frame to be retained and repainted black, semigloss 1'-0" canvas valence to read "Louisiana Bistro," with the L and B to measure 8 3/4" tall, other letters measuring between 4 3/4" and 7 1/4" per drawing stamped VCC approved 11/13/15
- Permit
- 15-30413-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 40
- Expires
- May 17, 2016
-
Permit VCC General Work Permit Issued
• Remove unpermitted balcony columns & handrail from service building and install "column #2" & "handrail #1", respectively, both per VCC standard detail sheet No. 11 (attached). • Replace service building soffit with T&G bead-board installed running perpendicular to street. • Paint new columns, handrail and soffit Benjamin Moore “Navajo White”. • Replace deteriorated metal roofing between main & service building with standing-seam painted galvanized metal (flat medium grey). • Remove vegetation and repoint and repair stucco as needed on all elevations using the following VCC approved formulas: Mortar: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part Portland Cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: No more than 1 Part Portland cement, 3 Parts Lime, 9 Parts Sand, Enough water to form a workable mix. Note: RATIO OF PORTLAND CEMENT NOT TO EXCEED 1:12. NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspect
- Permit
- 14-17649-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 24
- Expires
- Dec 5, 2014
-
Permit Renovation (Non-Structural) Permit Issued
Work Descripton: RE-POINT REAR BRICK WALL AS PER VCCP-11-0983. Historical Import Type: Permits Commercial Renovation (Non-Structural) NA User: CCROSS Tracking: 86114507246 Status: Permit Issuance Active Status Date: 1/13/2012 12:00:00 AM Owner: Mercier Realty And Investment Co Owner Address: 306 Dauphine St, New Orleans, LA 70112 Owner Edited By: 1/13/2012 by CCROSS
- Permit
- 12COM-00059
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $8,000
- Fees
- $150
- Days from application to issue
- 0
- Expires
- Jul 13, 2012
-
Code enforcement Case ENVHADJ-10-00006 Closed
A hearing was held on 07/28/2010 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Violation Occupied
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 25-39853-VCGEN.
-
Code enforcement Case ENVHADJ-984617SN Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 25-39853-VCGEN.
-
Code enforcement Case ENVHADJ-922922SH Closed
The property was inspected on 04/10/2009 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 20-29802-RSTC.
-
Permit Interior Demolition Application Acceptance - Approved No Review
INTERIOR DEMOLITION TO COMMERCIAL BUILDING
- Permit
- 08COM-00411
- Type
- Interior Demolition
- Work
- NA
- Estimated cost (applicant’s figure)
- $5,500
- Fees
- $80
- Days from application to issue
- 5
-
Permit General Mechanical Inspection - Completed
#14678 Katrina Reconnect ,
- Permit
- 05MCH-05917
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Dr.Pipe
- Days from application to issue
- 5
-
Permit Building
GENERAL REPAIRS VACANT COMMERCIAL BLDG. REPAIR EXTERIOR BRICKWALL AND STUCCO, REPLACE BEADED CEILING AT GALLERY AS PER SKETCH,DEPT OF PUBLIC WORKS #2004-011 & VCC PERMIT #040076.NO USE & OCCUPANCY.
- Permit
- B04001112
- Type
- Building
- Days from application to issue
- 0
Placed here by its tax bill number from “345 DAUPHINE ST”.
-
Permit Building
GENERAL REPAIRS VACANT COMMERCIAL BLDG. INTERIOR SHORING TO 1ST FLOOR VACANT COMMERCIAL SPACE AS PER ENGINEERS LETTER. NO EXTERIOR WORK ALLOWED
- Permit
- B03000385
- Type
- Building
- Days from application to issue
- 0
Placed here by its tax bill number from “345 DAUPHINE ST”.