French Quarter
801 Bourbon Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 35 permits on record here. 25 are still open. There was 1 past code enforcement case, the latest in September 2026, all closed. On this block in the past year: 868 requests to 311 and 179 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 3,900 sq ft
- Parcel
- 41023209
Everything on record here
36 records, newest first · 25 open
-
Code enforcement Case 26-10842-MPM Closed
The case was filed on 09/22/2026 but has since been closed without further action.
The city links this case to permit 26-19511-SPMA.
-
Permit Permit Permit not required
Birthday Second Line 8/1/26 - 12 Noon to 12:30
- Permit
- 26-19511-SPMA
- Application submitted
- Application review
-
Permit Mechanical HVAC Permit Issued
Install (1) 15 Ton Airhandler and (2) 6 Ton Condensers with 20KW Heat
- Permit
- 25-32906-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $49,714
- Fees
- $94
- Contractor
- Sidney Orin Lee
- Days from application to issue
- 1
- Expires
- Apr 22, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Permit Permit not required
Second line through the french quarter; delegates, staff, and guests of USA World Pageants; approximately 80-90 people parading; live second line band; no trash; walking only; no public admission; no rentals or vendors or vehicles; November 8, 2025 from 5-6pm; attendees will gather on the sidewalk outside the Bienville House hotel at 4:45; second line to begin at 5pm sharp on the intersection of Decatur and Bienville - parade up Bienville 3 blocks - turn right on Bourbon - parade 6 blocks - end at Bourbon Pub and Parade bar at the intersection of Bourbon and St. Ann; band and guests will disperse before 6pm and most will go inside the bar
- Permit
- 25-28072-SPMA
- Application submitted
- Application review
-
Permit VCC General Work Other
Retain rooftop mechanical equipment and safety rail, per 10/10/2023 Architecture Committee approval and attached materials stamped VCC approved 10/26/2023. NOTE: Gutters and downspouts previously cited as a violation are prescribed, but future work must be corrected. Do not alter or replace existing conditions without VCC approval. NOTE: Permit issued in response to violations but does not address all existing Vieux Carré Commission violations. Additional application(s) need to be submitted within sixty (60) days to address remaining violations. Failure to do so may result in this property being scheduled for an administrative adjudication hearing and subject to fines.
- Permit
- 23-25329-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 41
- Expires
- Apr 26, 2024
-
Permit Renovation (Non-Structural) Other
Request to retain the gutters and downspouts which are installed following a 1990 fire which destroyed the second and third floors as well as the roof. They appear in VCC photographs since then and were not cited in other violation letters as recently as 2021. Request to retain the AC condensers and guard rail. There is no other location to relocate the units and newer units will be larger. The units have been there for at least 20 years according to the owner.
- Permit
- 23-25329-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $100
- Fees
- $188
- Application submitted
- Zoning review
-
Permit VCC General Work Permit Issued
***ALL WORK TO MATCH EXISTING Replace rotten exterior porch decking as needed. Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached).
- Permit
- 23-22799-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- Feb 21, 2024
-
Permit Renovation (Non-Structural) Other
Replace rotten exterior porch decking as needed.
- Permit
- 23-22799-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,773
- Fees
- $203
- Contractor
- Anderson Real Estate Development LLC
- Application submitted
- Application review
- Zoning review
-
Permit VCC General Work Permit Issued
• Remove deteriorated floor boards, stringers, and fascia boards. • Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). • All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
- Permit
- 23-21631-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 1
- Expires
- Feb 9, 2024
-
Permit Renovation (Non-Structural) Permit Cancelled
Repairs to exterior deck. Repairs to interior tile. Re-install handrail interior.
- Permit
- 23-21631-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,773
- Fees
- $203
- Contractor
- Anderson Real Estate Development LLC
- Application submitted
-
Permit Renovation (Non-Structural) Application Accepted
Remove deteriorated mortar and repoint as needed. Natural Hydraulic Lime mortars only; No Portland Cement. Hand tools only.
- Permit
- 22-09590-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $49,218
- Fees
- $465
- Contractor
- Cypress Building Conservation, LLC
- Application submitted
-
Permit VCC General Work Permit Issued
Repair slates of dormer cheeks and reset moved ridge tiles. To repoint masonry utilizing Natural Hydraulic Lime Any deteriorated, cracked, or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. All reinstalled masonry must be properly "toothed in" to existing masonry wall, using VCC mortar formula (attached). Lath of any kind is prohibited unless preapproved by VCC staff prior to installation. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. MORTAR IS NOT TO BE APPLIED OVER THE FACE OF THE BRICKS UNDER ANY CIRCUMSTANCES. VOIDS IN THE BRICK ARE NOT TO BE FILLED WITH MORTAR. BROKEN, DETERIORATED BRICKS MUST BE REPLACED WITH BRICKS MATCHING THE PREVIOUS. Doing so will result in a STOP WORK ORDER being placed on the property and violation case will be opened on the property. Tighten Security camera line to verandah outlookers Miscellaneous millwork repairs matching existing details.
- Permit
- 21-35531-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Jul 10, 2022
-
Permit Renovation (Non-Structural) Other
1. Repair slates of dormer cheeks and reset moved ridge tiles. 2. Tuck point masonry with Natural Hydraulic Lime. 3. Tighten Security camera line to verandah outriggers 4. Miscellaneous millwork repairs matching existing details.
- Permit
- 21-35531-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,000
- Fees
- $113
- Contractor
- Roof Technologies, Inc.
- Application submitted
- Zoning review
-
Permit Street Cut Inspection Phase
Permit for 900 Block of Bourbon Street to start on December 28, 2020.
- Permit
- 20-40223-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $243
- Days from application to issue
- 96
- Expires
- Jun 14, 2021
-
Permit VCC Paint Other
Utility (Entergy Gas) work required to convert customer onto new High Pressure gas lines being installed with City Reconstruction Project. A gas service line will be installed from sidewalk base and elbow into building for gas supply. An iron curb valve access port will be installed at sidewalk surface with below grade valve for emergency service isolation. New pipe will be paint to match the adjacent surface.
- Permit
- 18-41221-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jul 22, 2019
-
Permit Street Cut Other
Remove and replace existing cellular equipment node w/ upgraded equipment.
- Permit
- 18-32079-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Days from application to issue
- 154
- Expires
- Aug 28, 2019
-
Permit VCC General Work Permit Finaled
Repair and paint second floor shutters to match existing. Shutters...Devoe, Blue Nile, semigloss Repair/replace glass in second floor door This is in response to a violation
- Permit
- 17-03306-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jul 30, 2017
-
Permit VCC General Work Permit Issued
Remove existing synthetic roofing material Repair and/or replace underlayment as necessary Install new natural slate (grey/green), using copper nails Install/repair half round copper gutters and flashing as needed Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets is not allowed Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. Tuckpoint masonry using VCC mortar formula (attached), removing dead mortar by hand. Cracked or broken bricks shall be replaced to match existing in color, size, material, porosity, detail, profile and exposure. Failure to exactly match materials, paint color, or VCC mortar as specified in permit will result in a VCC violation and mandated repair of improper work. All mortar to be mixed using the VCC recipe (attached) with a maximum of 1 part Portland Cement, to 3 parts lime, to 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted. Remove abandoned wiring on exterior of building and secure wires tightly, placed along the inside corners of building surfaces as much as possible, such as along gallery purlins at the deck line, and painted to match the adjacent surfaces.
- Permit
- 17-01669-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Contractor
- Leo Saune,Jr
- Days from application to issue
- 0
- Expires
- Jul 17, 2017
-
Permit VCC Paint Permit Issued
shutters: Devoe, Blue Nile (to match existing), semigloss
- Permit
- 17-00504-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Jul 6, 2017
-
Permit VCC General Work Application Accepted
Correct VCC Violations: 1.Replace the back roof slope of synthetic slate with natural grey slate. 2. Tuck point the masonry with VCC formula mortar where missing/defective. 3. Remove abandoned wires and strap loose wires. 4. Replace surface mount exterior signage with small interior mount signage in one pane of glass. 5. Appeal the installation of the iron gates on the first floor french doors with out a permit. 6. Appeal the HVAC units and guard rail originally installed here in 1976 and replaced in 1990 following a fire.
- Permit
- 16-40879-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Other
Correct VCC Violations: 1.Replace the back roof slope of synthetic slate with natural grey slate. 2. Tuck point the masonry with VCC formula mortar where missing/defective. 3. Remove abandoned wires and strap loose wires. 4. Replace surface mount exterior signage with small interior mount signage in one pane of glass. 5. Appeal the installation of the iron gates on the first floor french doors with out a permit. 6. Appeal the HVAC units and guard rail originally installed here in 1976 and replaced in 1990 following a fire.
- Permit
- 16-40879-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $80,000
- Fees
- $690
-
Permit VCC General Work Permit Issued
To retain opening on Dauphine elevation created without a permit, per drawings approved by the AC 8/12/14 and stamped approved 8/18/14.
- Permit
- 14-25800-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 25
- Expires
- Feb 18, 2015
-
Permit VCC Paint Permit Issued
-paint to match existing
- Permit
- 13-09647-VCPNT
- Type
- VCC Paint
- Work
- VCC Paint
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Sep 28, 2013
-
Permit Electrical Permit Issuance Active
REPAIRS- 11COM-00960
- Permit
- 11ELC-07181
- Type
- Electrical
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
-
Permit Commercial Permit Issuance Active
REMOVE DETORIORATED GALLER FLOOR BOARDS AND STRINGERS. INSTALL NEW FASCIA BOARD,PRIME,PAINT NEW WOODWORK;RAILINGS AND OTHERS AS PER VCCP-11-0496.
- Permit
- 11COM-00960
- Type
- Commercial
- Work
- NA
- Estimated cost (applicant’s figure)
- $30,000
- Fees
- $315
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-06478
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $149
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT OFFICE BUILDING REPLACE EXISTING 15-TON A\C SYSTEM. OCTAVE PEPPO - 738-3002
- Permit
- M03003749
- Type
- Mechanical
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2003 PAID FOR 1
- Permit
- S03000754
- Type
- Sign
- Days from application to issue
- 0
-
Permit Building
BRACING BAR/COCKTAIL CERTIFICATE OF OCCUPANCY FOR BRACING 2-20-03 - 3-05-03 AS PER SKETCH, DPW #MG-2003-554, OWNER'S & ENGINEER'S LETTER, & VCC PERMIT #030155.
- Permit
- B03001126
- Type
- Building
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT BAR/COCKTAIL REPLACE ELEC WARM AIR FURNACE AND TWO 3-TON A\C CONDENSING UNIT. OCTAVE PEPPO - 738-3002
- Permit
- M02007738
- Type
- Mechanical
- Days from application to issue
- 4
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE
- Permit
- S02000585
- Type
- Sign
- Days from application to issue
- 0
-
Permit Building
BRACING BAR/COCKTAIL CERTIFICATE OF OCCUPANCY FOR TEMPORARY BRACING FEBUARY 7,2002 THRU FEB.13,02 AS PER OWNER'S,ENG'S LETTER,DPW MG-2002- 559 AND VCC#020125.
- Permit
- B02000642
- Type
- Building
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT BAR/COCKTAIL INSTALL GAS WARM AIR FURNACE AND TWO 8-TON A\C ON ROOF. CHUCK SARDI. 738-3061
- Permit
- M01002916
- Type
- Mechanical
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN FEE 2001 PAID
- Permit
- S01000178
- Type
- Sign
- Days from application to issue
- 0
-
Permit Building
BRACING NIGHTCLUB BALCONY SUPPORTS FOR NON-CONFORMING NIGHTCLUB FROM 9/2 TO 9/9/98 AS PER ENGINEER'S LETTER, OWNER'S LETTER, APP- ROVAL FROM DEPT OF PUBLIC WKS. & VCC.
- Permit
- B98004536
- Type
- Building
-
Permit Sign
PROJECTING SIGN BAR/COCKTAIL SIGN OPERATING FEE FOR 1998 CAPRICORN PRODS.INC./THE BOURBON PUB
- Permit
- S98000193
- Type
- Sign