French Quarter

1014 Bourbon Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 10 permits on record here; the most recent, a renovation (non-structural) permit, was filed in May 2020. 2 are still open. On this block in the past year: 8 requests to 311 and 61 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
6
Lot size
2,936 sq ft
Parcel
41023252

Everything on record here

10 records, newest first · 2 open

  1. Permit Renovation (Non-Structural) Other

    install water service

    Permit
    20-27948-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,780
    Fees
    $150
    1. Application submitted

    See this permit on One Stop

  2. Permit VCC General Work Permit Finaled

    To renovate building, correct violations, and paint as per materials stamped VCC approved 10/19/17. Work includes but is not limited to: • Removal of lattice above handrail on the second floor of the Ursulines elevation • Removal of the thru-wall air condition units from the first and second floors of the Ursulines elevation and repair of those walls with new wood weatherboards feathered into existing weatherboards • Removal of deteriorated and loose stucco on the Bourbon St. elevation and application of new stucco mixed and applied as per VCC standard detail sheet (attached) • Removal of termite damaged lintel above window on the first floor of the Bourbon St. elevation and installation of new wood lintel matched to existing/adjacent Removal of existing fencing from the first floor of the Ursulines elevation and installation of new wood baluster matched to existing second floor baluster/1992 photograph • To prepare for painting by washing using a low water pressure (400 psi max) and/or sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: Walls...Jonquil, SW 6674, flat or satin finish Wooden elements including doors, windows, frames, shop windows, fascia/soffit/outriggers of gallery... White/off-white, matched to existing main pedestrian door, semiglo

    Permit
    17-34676-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    7
    Expires
    Apr 19, 2018

    See this permit on One Stop

  3. Permit Renovation (Non-Structural) Other

    Repair broken hand rails, prep and paint exterior siding, replace damaged columns, remove fencing per VCC request, repair deck boards.

    Permit
    17-34676-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $15,000
    Fees
    $203
    Contractor
    TASCH LLC

    See this permit on One Stop

  4. Permit VCC General Work In Review

    Attached scope of work narrative and estimated cost is to resolve the violation case number 17-01703-DBNVCC. This building is a school. Renovations include cleaning the exterior, painting, and various repairs to bring the building into compliance.

    Permit
    17-19524-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  5. Permit Renovation (Structural) Other

    Resolve the violation case number 17-01703-DBNVCC: clean exterior, painting, and various repairs

    Permit
    17-19524-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $106,535
    Fees
    $1,053
    Contractor
    C Spencer Smith, AIA Architects

    See this permit on One Stop

  6. Permit VCC General Work Permit Cancelled

    Tie-in of exisitng balcony flat bar supports to existing timber beam in building interior. Balcony to be jacked up with 1/8" slope prior to installation of flat bar tie-ins. Existing interior ceiling to be replaced as existing after structural work. Any rotten fascia wood to be removed and replaced as existing. 2016.04.05 - Permit not picked up. Some work done.

    Permit
    15-15147-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 27, 2015

    See this permit on One Stop

  7. Permit Renovation (Structural) Permit Cancelled

    Tie-in of exisitng balcony flat bar supports to existing timber beam in building interior. Balcony to be jacked up with 1/8" slope prior to installation of flat bar tie-ins. Existing interior ceiling to be replaced as existing after structural work. Any rotten fascia wood to be removed and replaced as existing as per 15-15147-VCGEN.

    Permit
    15-15147-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $3,033
    Fees
    $120
    Contractor
    Ja'lia Construction

    See this permit on One Stop

  8. Permit VCC General Work Permit Cancelled

    Remove all 1in. x 4in. & 1in. x 6in.. damaged tongue & groove balcony flooring and ceiling. Raise and support the balcony with hydraulic jacks, remove sections of 6' balcony fence railing to gain access for removal of one 3in. x 6in. x 12' long balcony support column. Remove two 1in. x 8in. x 14' sections of facial Replace all above lister water damaged wood with new pressure treated lumber of the same size and likeness. Caulk and paint new wood to match the existing. Barricade across the Bourbon St. side of the cottage and erect temporary column/braces to support the second level balcony. Jack the front balcony pup to a standard/level height and remove the existing metal braces. Make new fabricated steel braces to properly support the balcony to a safe, secure position. Repair & paint damaged T&G flooring and ceiling.

    Permit
    14-29732-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  9. Permit Renovation (Structural) Other

    Remove all 1in. x 4in. & 1in. x 6in.. damaged tongue & groove balcony flooring and ceiling. Raise and support the balcony with hydraulic jacks, remove sections of 6' balcony fence railing to gain access for removal of one 3in. x 6in. x 12' long balcony support column. Remove two 1in. x 8in. x 14' sections of facial Replace all above lister water damaged wood with new pressure treated lumber of the same size and likeness. Caulk and paint new wood to match the existing. Barricade across the Bourbon St. side of the cottage and erect temporary column/braces to support the second level balcony. Jack the front balcony pup to a standard/level height and remove the existing metal braces. Make new fabricated steel braces to properly support the balcony to a safe, secure position. Repair & paint damaged T&G flooring and ceiling.

    Permit
    14-28782-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $6,700
    Fees
    $143

    See this permit on One Stop

  10. Permit VCC General Work Other

    Historical Import Type: Enforcement VCC Permit General User: CABERG Tracking: 86139375316 Status: Permit Issued Status Date: 4/5/2012 12:00:00 AM Owner: Orleans Parish School Board Owner Address: 1641 Poland Ave., New Orleans, LA 70117 Owner Phone: 301-6954 Owner Edited By: 4/11/2012 by CABERG To remedy Violations noted 02/16/12: -Plywood panel and window air-conditioning unit, installed without approval or permit, to be removed from 1st floor Bourbon St. window opening. -Previously existing casement window with three lites and a panel on each side is to be restored and painted to match existing, per photograph approved 04/05/12. -Plywood panel at 2nd floor Bourbon St. balcony, installed without approval or permit, to be removed. -Previously existing pair of French doors to be restored to match existing. -All millwork to be painted to match existing. NOTE: All millwork to be repaired to match existing, as required. -All circular round surface mounted fluorescent fixtures, installed without approval or permt, to be removed from soffit and beneath balcony. -2nd floor soffit to receive five (5) recessed can fixtures; soffit underneath balcony to receive five (5) surface mounted can fixtures. -Locations of all fixtures to be confirmed with VCC staff prior to installation. -Wattage of each fixture not to exceed 75 watts. -All fixtures to be submitted to VCC for approval prior to installation. -Damaged masonry and stucco pier at Bourbon St. driveway ent

    Permit
    VCCP-12-0333
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

    Placed here by a known alternate street name from “1014 Bourbon”.