French Quarter
434 Chartres Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 7 permits on record here; the most recent, a VCC general work permit, was filed in July 2025. 6 are still open. On this block in the past year: 3 requests to 311 and 86 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 4
- Lot size
- 1,478 sq ft
- Parcel
- 41023378
Everything on record here
7 records, newest first · 6 open
-
Permit VCC General Work Permit Issued
Replace rain gutter and downspouts in same locations. all new gutters and downspouts to be same size as exising material copper
- Permit
- 25-20397-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 6
- Expires
- Jan 14, 2026
-
Permit Renovation (Non-Structural) In Review
Replace rain gutter and downspouts.
- Permit
- 25-20397-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1,000
- Fees
- $125
- Contractor
- Audubon Gutters
- Application submitted
-
Permit VCC General Work Permit Issued
MAIN ROOF: Remove existing roofing material Repair and/or replace underlayment as necessary Install new 16” x 10” natural slate (grey/black), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers REAR ROOF: TPO gray/ non reflective any stucco applied/ used is to be VCC approved stucco mix. See below: Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 22-36007-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 32
- Expires
- Jul 3, 2023
-
Permit Renovation (Non-Structural) Permit Issued
MAIN ROOF: Remove existing roofing material Repair and/or replace underlayment as necessary Install new 16” x 10” natural slate (grey/black), using copper nails Install/repair half round copper gutters and flashing Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. Metal cap-flashing on the parapets or chimneys is not allowed If synthetic tiles are used, they are NOT to be wrapped/ capped at the edge of the roof or dormers REAR ROOF: TPO gray/ non reflective any stucco applied/ used is to be VCC approved stucco mix. See below: Stucco: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: • no greater than 1:12 part Portland Cement, to • 3 parts lime, and • 9 parts sand, • 6 lbs./cubic yard hair or fiber, and • enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: • No more than 1 Part Portland cement, • 3 Parts Lime, • 9 Parts Sand, • Enough water to form a workable mix. PREPACKAGED MIXES ARE NOT PERMITTED. Note: Trash chutes are required for removal of debris from all roofs. All work must conform to standard VCC policies & guidelines. Permit does not allow for cap flashing on parapets, chimneys or surrounding walls. Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 22-36007-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $44,240
- Fees
- $518
- Contractor
- CMR Construction & Roofing
- Days from application to issue
- 825
- Expires
- Sep 5, 2025
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- First inspection
- Issue date
-
Permit Renovation (Non-Structural) Application Acceptance - Approved No Review
Remodeling work to include: Preparation for painting,Sanding,Drywall,Stairs;Downspouts as per VCCP-10-0147.
- Permit
- 10BLD-01364
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $35,000
- Fees
- $353
- Days from application to issue
- 5
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
6 months vacancy
- Permit
- 07ELC-15935
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Days from application to issue
- 11
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-05130
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0