French Quarter
831 Saint Louis Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 26 permits on record here; the most recent, a VCC general work permit, was filed in April 2026. 7 are still open. On this block in the past year: 2 requests to 311 and 82 calls to police.
- Zoning
- VCR-1
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 8,371 sq ft
- Parcel
- 41023446
Everything on record here
26 records, newest first · 7 open
-
Permit VCC General Work Other
Renovating apartment. Adding a few walls and a few closets. Painting and updating all trim, work. Updating electrical, plumbing and HVAC fixtures,
- Permit
- 26-12393-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Permit Cancelled
Renovating apartment. Adding a few walls and a few closets. Painting and updating all trim, work. Updating electrical, plumbing and HVAC fixtures, Work limited to single unit only, no exterior work, no work on hallways or corridor, no work on other units.
- Permit
- 26-12393-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $176,753
- Fees
- $1,122
- Application submitted
-
Permit VCC General Work Other
dormer windows broken by hurricane ida to be replaced with identical windows as those that were damaged. lights and String lights on third floor balcony, right side to be removed. cox cable and att will be contacted to remove unnecessary wires. Small crack in masonry on first floor facade to be pointed. cornice to be painted. Contractors are being sought to perform these repairs and emergency approval is sought to allow these windows to remain boarded until replacement windows can be constructed and installed.
- Permit
- 22-23232-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) In Review
dormer windows broken by hurricane ida to be replaced with identical windows as those that were damaged. lights and String lights on third floor balcony, right side to be removed. cox cable and att will be contacted to remove unnecessary wires. Small crack in masonry on first floor facade to be pointed. cornice to be painted. Contractors are being sought to perform these repairs and emergency approval is sought to allow these windows to remain boarded until replacement windows can be constructed and installed.
- Permit
- 22-23232-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,000
- Fees
- $218
- Application submitted
- Zoning review
-
Permit VCC General Work Permit Cancelled
Tile right of meter socket is overheated and loose. Need to shut utility power off and replace part inside 100 amp meter socket.
- Permit
- 20-43806-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Apr 16, 2021
-
Permit Electrical Repair / Replacement / Addition Other
Tile right of meter socket is overheated and loose. Need to shut utility power off and replace part inside 100 amp meter socket.
- Permit
- 20-43806-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $692
- Fees
- $40
- Contractor
- Donovan Nicholas Michael MICHAEL Michael
- Application submitted
- Application review
- Permit approved
-
Permit VCC General Work Other
repair leaking torchdown roof
- Permit
- 19-28752-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- Mar 20, 2020
-
Permit Renovation (Non-Structural) Other
repair leaking torchdown roof
- Permit
- 19-28752-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $7,280
- Fees
- $150
- Contractor
- Precision Roofing & Construction
- Application submitted
-
Permit VCC General Work Permit Cancelled
All work as per materials stamped VCC approved 11/10/17 as follows: • Remove existing unpermitted asphalt shingle roofing material from rear service wing • Repair and/or replace underlayment as necessary • Install new natural slate (grey/green), using copper nails, on majority of the roof • Install new copper standing seam roof on the low sloped portion of the roof indicated on stamped approved plans • Install/repair half round copper gutters and flashing • Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Metal cap-flashing on the parapets is not allowed Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapet or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré. All repair/replacement work shall match existing in color, size, material, detail, profile and exposure.
- Permit
- 17-25294-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 109
- Expires
- May 10, 2018
-
Permit Renovation (Non-Structural) Other
Retain the Asphalt shingle roof, flashing, and chimney sealants on the Garconniere building.
- Permit
- 17-25294-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $50,000
- Fees
- $555
- Days from application to issue
- 285
- Expires
- Nov 2, 2018
-
Permit VCC General Work Permit Finaled
Replac fascia boards on sencond and third floor galleries on the St Louis elevation Painting underside of gallery on the St Louis elevation, white, semigloss (to match existing) Repair second floor shutters (to match existing) repaint entryway. white, semigloss (entryway to match existing)
- Permit
- 17-24473-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 3
- Expires
- Jan 24, 2018
-
Permit Renovation (Non-Structural) Other
Replace fascia boards on front galleries floors 2 and 3, paint underside of front Gallery, repair shutters on 2nd floor, paint front entrance
- Permit
- 17-24473-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $2,000
- Fees
- $105
-
Permit VCC General Work Permit Issued
Remove and replace aluminum gutters and downspout along the Duphine elevation of both the main house and the dependancy structure. Gutters are to be painted to match the adjacent surface.
- Permit
- 16-23623-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Feb 9, 2017
-
Permit Renovation (Non-Structural) Other
Replace most gutters like for like along back-side of main building and garconniere. Some gutters will just be tuned up (tightened up against the roof fascia). Replace one downspout.
- Permit
- 16-23623-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $6,400
- Fees
- $143
- Contractor
- Audubon Gutters
-
Permit Renovation (Non-Structural) Other
Repair and caulk 7 exterior window sills and stucco cracks on back-side of main building then paint.
- Permit
- 16-23619-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $14,800
- Fees
- $203
- Contractor
- Southeast Waterproofing & Distributors
-
Permit VCC General Work Permit Finaled
To repair existing metal surround which supports and operates existing wooden carriageway doors as needed to match existing conditions. Repair/replace metal door frame and hinges as needed to match existing conditions. To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork repairs as necessary to match existing conditions and to paint gate and surround French Quarter Green, semigloss, to match existing conditions All repair/replacement work shall match existing in color, size, material, detail, profile and exposure
- Permit
- 16-14766-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 7
- Expires
- Nov 19, 2016
-
Permit VCC General Work Permit Finaled
Repoint brick masonry and repair cracks as needed, using appropriate lime mortar and matching the existing joint profiles, per VCC information sheet (attached). Replace broken or worn bricks as needed with bricks to match existing material. Areas of repair to be Bourbon elevation of main building.
- Permit
- 16-15283-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 6
- Expires
- Nov 18, 2016
-
Permit Renovation (Structural) Other
Tuck and Point building wall on river side. Doing probably half the wall over 2 weeks.
- Permit
- 16-15283-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $32,000
- Fees
- $420
-
Permit Renovation (Non-Structural) Other
Repairing Carriageway gate. Refurbish wood and door components, Build new metal frame and supports, new steel hinges, prepare and paint to original color (French Quarter Green).
- Permit
- 16-14766-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $3,000
- Fees
- $143
- Contractor
- SES Enterprises
-
Permit VCC General Work Permit Finaled
Replace downspout on façade of building with a larger diameter downspout. Located on right hand side of building when facing St. Louis street.
- Permit
- 15-20852-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Expires
- Jan 17, 2016
-
Permit Renovation (Non-Structural) In Review
Replace downspout on façade of building with a larger diameter downspout.
- Permit
- 15-20852-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $1,000
- Fees
- $98
-
Permit VCC General Work Permit Finaled
Repoint brick masonry and repair cracks as needed, using appropriate lime mortar. Replace several broken or worn bricks as needed with bricks to match existing material. Areas of repair include most of the riverside, and the lakeside walls of the building, and some areas on the St. Louis St. façade.
- Permit
- 12-31591-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $4,000
- Fees
- $0
- Contractor
- Pat Akins
- Days from application to issue
- 0
- Expires
- May 28, 2013
-
Permit VCC General Work Permit Issued
1. Fabricate and install 7 pairs of board & batten shutters on 3rd floor of rear dependency facing courtyard: 3 windows, 4 doors. 2. All shutters will be made of Spanish cedar, and will match the style of existing shutters on ground floor of dependency and will be painted to match: Sherwin Williams SW6614 "Quite Coral." (See photos received with application.) Note: All shutters must be fabricated according to attached drawing indicated and stamped on attached VCC Architectural Detail sheet for shutters. Specifically: shutter boards must be 6” or wider tongue and groove and beaded on one edge on both sides.
- Permit
- 12-31626-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $8,200
- Fees
- $0
- Days from application to issue
- 0
- Expires
- May 28, 2013
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL 2-TON A\C AND ELEC WARM FURNACE. KENNETH ROBERT 282-0625
- Permit
- M02000268
- Type
- Mechanical
- Days from application to issue
- 1
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL ELEC WARM AIR FURNACE AND 2-TON A\C. KENNETH ROBERT 282-0625
- Permit
- M02000284
- Type
- Mechanical
- Days from application to issue
- 1
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING INSTALL ELEC WARM AIR FURNACE AND 3-TON A\C. KENNETH ROBERT 282-0625
- Permit
- M02000285
- Type
- Mechanical
- Days from application to issue
- 1