French Quarter

510 Wilkinson Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 15 permits on record here; the most recent, a VCC general work permit, was filed in May 2021. 12 are still open. On this block in the past year: 1 request to 311 and 46 calls to police.

Zoning
VCC-2
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
5
Lot size
1,993 sq ft
Parcel
41023468

Everything on record here

15 records, newest first · 12 open

  1. Permit VCC General Work Other

    Approval to add shutters to existing doors on first floor front of building. Note: This permit applies to Parcel #207100921 only. The other units are not included in the work despite the reference for all PIN numbers for the other units.

    Permit
    21-13041-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Application Accepted

    Approval to add shutters to existing doors on first floor front of building. Note: This permit applies to Parcel #207100921 only. The other units are not included in the work despite the reference for all PIN numbers for the other units.

    Permit
    21-13041-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $7,500
    Fees
    $150
    1. Application submitted

    See this permit on One Stop

  3. Permit VCC General Work Permit Issued

    Remove vegetation growing from the building Repair, repoint bricks per VCC attachment Remove damaged stucco, apply new stucco per VCC attachment (Stucco application is NOT approved on the Wilkinson elevation bricks) Repair wood, window & door damage, to match existing Clean rusted tie rods To prepare for painting by washing using a low water pressure (400 psi max) and/or sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions (masonry mix must be soft, with maximum Portland cement content not to exceed 1 part to 12) and to paint as follows to match existing conditions: Walls..."Cream", flat & satin, to match existing Wilkinson elevation doors..."Red", semigloss, to match existing Windows..."White, Off-white", semigloss Trim..."White, Off-white", semigloss

    Permit
    20-28456-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 18, 2020

    See this permit on One Stop

  4. Permit VCC General Work Other

    Roof replacement and repair @ rear, flat roof, per attached materials stamped VCC approved 01/22/19, as follows: Replace flat roof with new 1" insulation and TPO. Note: TPO must be medium gray finish. Replace flashing to match existing. Install in existing mortar joint or reglet. Do not cut new reglets. Replace deteriorated roof hatch to match existing, Repair existing roof drain.

    Permit
    18-36901-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    71
    Expires
    Jul 22, 2019

    See this permit on One Stop

  5. Permit Renovation (Non-Structural) Permit Cancelled

    remove existing flat roof install new Grey TPO roof system install new hatch cover

    Permit
    18-36901-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $14,200
    Fees
    $203
    Contractor
    Duxworth Roofing
    1. Application submitted
    2. Application review

    See this permit on One Stop

  6. Permit VCC General Work Permit Issued

    Construction of new elevator penthouse on Decatur side of rear (Toulouse) roof slope: clad in corrugated metal, devoid of windows, fenestration, gabled roof, and any historic dormer detailing, per drawings stamped VCC approved 12/17/14.

    Permit
    14-37062-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    16
    Expires
    Jun 17, 2015

    See this permit on One Stop

  7. Permit Renovation (Non-Structural) Permit Issued

    Construct new Dormer and install new elevator as per plans, 14-37062-VCGEN, and Motion Number M-14-485.

    Permit
    14-37062-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $12,000
    Fees
    $270
    Contractor
    Henry L Levet Architect, Eddie Wolff Construction Co
    Days from application to issue
    60
    Expires
    Jul 30, 2015

    See this permit on One Stop

  8. Permit VCC Paint Permit Finaled

    Remove deteriorated stucco finish Repoint river-side, masonry elevation using VCC approved mortar formula: No more than 1 part Portland Cement, 3 parts lime, 9 parts sand, and enough water to form a workable mix. Prepackaged mixes are not permitted, as quality control is not consistent. Stucco river-side elevation using VCC approved stucco formula: Base coat consists of 2 coats, doubled up work of 5/8" total thickness. Proportioned as follows: no greater than 1:12 part Portland Cement, to 3 parts lime, and 9 parts sand, 6 lbs./cubic yard hair or fiber, and enough water to form a workable mix. Finish coat is 1/4" in total thickness proportioned as follows: No more than 1 Part Portland cement, 3 Parts Lime, 9 Parts Sand, Enough water to form a workable mix. To prepare for painting by sanding (rotary sanders cannot be used), making minor millwork and masonry repairs as necessary to match existing conditions and to paint as follows to match existing conditions: Walls...Synergy (latex), flat or satin finish This permit prohibits the application of the following exterior coating materials and paints: sealers, ceramic coatings/paints, elastomeric coatings/paints, waterproofing/water repellent coatings.

    Permit
    14-27042-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    16
    Expires
    Feb 28, 2015

    See this permit on One Stop

  9. Permit Renovation (Structural) Permit Issuance - Active

    INSTALL ELEVATOR SHAFT AND ELEVATOR PER SKETCH - NO EXTERIOR

    Permit
    11BLD-03923
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $36,290
    Fees
    $245
    Days from application to issue
    0
  10. Permit Certificate of Occupancy Certificate Issued No Meter

    Convert vacant commercial retail space to office use as per sketch. No electrical, mechanical, architectural work to be done. No exterior work allowed under this permit.

    Permit
    04OCC-00506
    Type
    Certificate of Occupancy
    Work
    NA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $150
  11. Permit Electrical

    ELECTRICAL VACANCY REPAIRS MULTI-FAMILY DWELLING LAWRANCE MARGIOTTA

    Permit
    E03008476
    Type
    Electrical
    Days from application to issue
    0

    Placed here by its map location from “531 WILKINSON ST”.

  12. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL 4-ELEC WATER HEATER. ON 1ST FLOOR THROUGHT 4TH FLR. ROBERT COMEAUX- 277-1042

    Permit
    M02000882
    Type
    Mechanical
    Days from application to issue
    0
  13. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL 2-ELEC WARM AIR FURN. WALTER LEWIS - 456-7875

    Permit
    M01007535
    Type
    Mechanical
    Days from application to issue
    5

    Placed here by the building address from “510 WILKINSON ST UNIT B”.

  14. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL ELEC WATER HEATER. WALTER LEWIS - 456-7895

    Permit
    M01007536
    Type
    Mechanical
    Days from application to issue
    5

    Placed here by the building address from “510 WILKINSON ST UNIT A”.

  15. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT MULTI-FAMILY DWELLING INSTALL ELEC WARM AIR FURNACE, FOUR 5-TON & 4-TON . ROBERT COMEAUX - 277-1042

    Permit
    M01003094
    Type
    Mechanical
    Days from application to issue
    0