Gert Town
4001 Earhart Boulevard is in Gert Town, zoned C-3 (Heavy commercial, auto-oriented, for large shopping centers). The city has 19 permits on record here; the most recent, a mechanical fuel gas permit, was filed in July 2026. 9 are still open. There were 2 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 0 requests to 311 and 2 calls to police.
- Zoning
- C-3
- Historic district
- None
- Council district
- B
- Ward
- 2
- Lot size
- 81,650 sq ft
- Parcel
- 41035755
Everything on record here
22 records, newest first · 9 open
-
Permit Mechanical Fuel Gas Other
Disconnect gasline and file for a seperate gas meter. 1. File for a new gas meter and coordinate installation with the gas utility. 2. Cap and reconnect the neighboring gas service as required. 3. Schedule and coordinate the required gas inspection. 4. Install approximately 40 linear feet of 3-inch black iron gas pipe. 5. Install approximately 100 linear feet of 2-inch gas piping with required fittings for the water heater. 6. Install approximately 100 linear feet of 1¼-inch gas piping and 100 linear feet of 1-inch gas piping to supply the rear hanging heater. 7. Install beam clamps with 3/8-inch stainless-steel threaded rods and stainless-steel clevis hangers spaced approximately every 10 feet. 8. Remove portions of the existing gas line and reconnect to the existing gas system where practical. 9. Pressure test the completed gas piping system before inspection. 10. Replace approximately 40 linear feet of existing non-code-compliant 3/4-inch gas pipe with new 1-inch gas pipe as required by the inspector. 11. Repairs to concealed leaks or deteriorated existing gas piping discovered during testing are not included and require written customer approval.
- Permit
- 26-22340-FGAS
- Type
- Mechanical Fuel Gas
- Work
- Mechanical Fuel Gas
- Estimated cost (applicant’s figure)
- $15,000
- Fees
- $171
- Contractor
- George Williams Schmitt
- Days from application to issue
- 1
- Expires
- Jan 30, 2027
- Mechanical Special Inspection Paid
- Floor Furnaces / Heaters Paid
- Gas Line and Outlets Paid
- Water Heaters Paid
- Rough Mech Gas Comm
- Special Mechanical
- Water Heater
- Application Submitted Complete
- Application submitted
- Application Review Complete
- Permit Approved Complete
- Permit Issued Complete
- Mechanical Permit Review Complete
- Application review
- Permit approved
- Issue date
- Air Conditioning Passed
- Gas Line Passed
- First inspection
- Inspections Finaled Complete
- Certificate of Completion Complete
- Meter Release - Gas Complete
- Mechanical Permit Review Complete
-
Permit Electrical Repair / Replacement / Addition Permit Finaled
UPGRADE OF ELECTRICAL SERVICE FROM 320a to 800a. WORK STARTED ON Permit #21-11987-SERV, BUT PERMIT EXPIRED DUE TO LONG LEAD TIME TO GET MATERIALS. account number 131283913, meter number 8003037.
- Permit
- 23-26949-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $56,495
- Fees
- $280
- Contractor
- Jeremy Chase Martin
- Days from application to issue
- 0
- Expires
- Apr 2, 2024
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Mechanical HVAC Permit Finaled
instsll one 3 ton ac w waf install one 5 ton ac w waf
- Permit
- 22-22236-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $2,150
- Fees
- $111
- Contractor
- JLJ Electrical And A/C dba JLJ Construction LLC
- Days from application to issue
- 7
- Expires
- Feb 1, 2023
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Electrical Repair / Replacement / Addition Permit Issued
Install 100 amp sub panel with 18 circuits for lighting. Reconfigure 3 phase air handler and compressor from existing circuit.
- Permit
- 22-10727-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $15,000
- Fees
- $94
- Contractor
- Arthur Joseph Hartsell
- Days from application to issue
- 2
- Expires
- Oct 13, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Renovation (Non-Structural) Occupancy
Reconfiguration of a portion of an existing business office area in an existing building. No addition.
- Permit
- 22-03228-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $37,940
- Fees
- $310
- Contractor
- Vincent Cangiamilla
- Days from application to issue
- 59
- Expires
- Oct 1, 2022
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit Renovation (Structural) Permit Issued
Demo concrete in warehouse; Remove broken 4 inch cast iron sewer line; Replace with pvc;
- Permit
- 21-30317-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $160
- Contractor
- Construction Solutions by Joey LLC
- Days from application to issue
- 0
- Expires
- Apr 28, 2022
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Small Cell Installation Other
UNIV 125 Replace existing wood utility pole with wood utility pole for small cell antenna installation S side Euphrosine St. approximately 70' from corner of S Dupre St.
- Permit
- 21-22266-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $1,000
- Application submitted
Placed here by its map location from “4090 Euphrosine St”.
-
Permit Electrical Service / Circuit / Feeder Permit Issued
INCREASE OF EXISTING 120/240V 3 PHASE ELECTRICAL SERVICE FROM 400A TO 600A. ENTERGY ACCOUNT #131283913 METER #8003037
- Permit
- 21-11987-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $24,485
- Fees
- $280
- Contractor
- Blanchard Timothy
- Days from application to issue
- 465
- Expires
- Feb 5, 2023
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Electrical Repair / Replacement / Addition Permit Issued
INSTALL 8 HIGH BAG LIGHTS 19 WALL PACK & REPALCE 200 AMP PANEL
- Permit
- 15-15876-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $118
- Contractor
- Hung The Nguyen
- Days from application to issue
- 20
- Expires
- Dec 16, 2015
-
Permit Electrical Service / Circuit / Feeder Permit Issued
NEW ELECTRICAL 14-26913-RNVS
- Permit
- 14-32342-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $220
- Contractor
- Hung The Nguyen
- Days from application to issue
- 0
- Expires
- Apr 20, 2015
-
Permit General Mechanical Inspection Phase
install 40-elect waf and 4 condenser unit. Thomas Mcginnis (#3164) 14-26058-Rnvn
- Permit
- 14-30175-MECH
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $210
- Contractor
- Thomas Mcginnis
- Days from application to issue
- 36
- Expires
- May 3, 2015
-
Permit Renovation (Structural) Occupancy
Tenant build-out of a food distributor as per attached drawings.
- Permit
- 14-26913-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $413,983
- Fees
- $2,544
- Contractor
- Timothy Terrell, Protocol Construction LLC
- Days from application to issue
- 33
- Expires
- Mar 30, 2015
-
Permit Renovation (Non-Structural) Permit Issued
roof repair
- Permit
- 14-26058-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $15,000
- Fees
- $135
- Days from application to issue
- 2
- Expires
- Feb 22, 2015
-
Permit Change of Address Permit Issued
Adding address for tenant space - 4040 Euphrosine. 4001 Earhart to remain.
- Permit
- 14-25492-ECOA
- Type
- Change of Address
- Work
- Change of Address
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 5
- Expires
- Feb 19, 2015
-
Permit Commercial Letter Response Pending
RENOVATE EXISTING OFFICE/STORAGE SPACE AS PER PLANS.
- Permit
- 11COM-00915
- Type
- Commercial
- Work
- NA
- Estimated cost (applicant’s figure)
- $55,000
- Fees
- $395
-
Code enforcement Case ENVHADJ-94765SZ Closed
The property was inspected on 03/29/1994 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 22-22236-HVAC.
-
Code enforcement Case ENVHADJ-953397SZ Closed
A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.
- Inspection: Inspection Complete
- Hearing: Initial Hearing Found Guilty
The city links this case to permit 22-22236-HVAC.
-
Permit General Mechanical Inspection - Completed
rll-d-dawson-489-5566-reconnect-1-wh-ck-13807
- Permit
- 08MCH-11026
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $50
- Contractor
- Built-In Appliance
- Days from application to issue
- 5
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 08ELC-13069
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Bellau Electric LLC
- Days from application to issue
- 10
-
Permit Electrical Service / Circuit / Feeder Application Acceptance - Approved
VACANCY -ADD 2 CIRCUITS
- Permit
- 07ELC-05385
- Type
- Electrical Service / Circuit / Feeder
- Work
- Service-Circuits-Feeders
- Estimated cost (applicant’s figure)
- $0
- Fees
- $66
- Contractor
- Stuart Electric Inc
- Days from application to issue
- 10
-
Permit Construction Loop Application Acceptance - Approved
const loop
- Permit
- 05ELC-09073
- Type
- Construction Loop
- Work
- Construction Loop
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Northside Electric
- Days from application to issue
- 10
-
City record Mechanical Fuel Gas
disconnecting gasline, and filing for a seperate gas meter.
- Mechanical Permit Review review Pending
- Mechanical Permit Review review Pending
See this record on One Stop · checked Nov 10, 2026