Gert Town

4001 Earhart Boulevard is in Gert Town, zoned C-3 (Heavy commercial, auto-oriented, for large shopping centers). The city has 19 permits on record here; the most recent, a mechanical fuel gas permit, was filed in July 2026. 9 are still open. There were 2 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 0 requests to 311 and 2 calls to police.

Zoning
C-3
Historic district
None
Council district
B
Ward
2
Lot size
81,650 sq ft
Parcel
41035755

Everything on record here

22 records, newest first · 9 open

  1. Permit Mechanical Fuel Gas Other

    Disconnect gasline and file for a seperate gas meter. 1. File for a new gas meter and coordinate installation with the gas utility. 2. Cap and reconnect the neighboring gas service as required. 3. Schedule and coordinate the required gas inspection. 4. Install approximately 40 linear feet of 3-inch black iron gas pipe. 5. Install approximately 100 linear feet of 2-inch gas piping with required fittings for the water heater. 6. Install approximately 100 linear feet of 1¼-inch gas piping and 100 linear feet of 1-inch gas piping to supply the rear hanging heater. 7. Install beam clamps with 3/8-inch stainless-steel threaded rods and stainless-steel clevis hangers spaced approximately every 10 feet. 8. Remove portions of the existing gas line and reconnect to the existing gas system where practical. 9. Pressure test the completed gas piping system before inspection. 10. Replace approximately 40 linear feet of existing non-code-compliant 3/4-inch gas pipe with new 1-inch gas pipe as required by the inspector. 11. Repairs to concealed leaks or deteriorated existing gas piping discovered during testing are not included and require written customer approval.

    Permit
    26-22340-FGAS
    Type
    Mechanical Fuel Gas
    Work
    Mechanical Fuel Gas
    Estimated cost (applicant’s figure)
    $15,000
    Fees
    $171
    Contractor
    George Williams Schmitt
    Days from application to issue
    1
    Expires
    Jan 30, 2027
    1. Mechanical Special Inspection Paid
    2. Floor Furnaces / Heaters Paid
    3. Gas Line and Outlets Paid
    4. Water Heaters Paid
    5. Rough Mech Gas Comm
    6. Special Mechanical
    7. Water Heater
    8. Application Submitted Complete
    9. Application submitted
    10. Application Review Complete
    11. Permit Approved Complete
    12. Permit Issued Complete
    13. Mechanical Permit Review Complete
    14. Application review
    15. Permit approved
    16. Issue date
    17. Air Conditioning Passed
    18. Gas Line Passed
    19. First inspection
    20. Inspections Finaled Complete
    21. Certificate of Completion Complete
    22. Meter Release - Gas Complete
    23. Mechanical Permit Review Complete

    See this permit on One Stop

  2. Permit Electrical Repair / Replacement / Addition Permit Finaled

    UPGRADE OF ELECTRICAL SERVICE FROM 320a to 800a. WORK STARTED ON Permit #21-11987-SERV, BUT PERMIT EXPIRED DUE TO LONG LEAD TIME TO GET MATERIALS. account number 131283913, meter number 8003037.

    Permit
    23-26949-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $56,495
    Fees
    $280
    Contractor
    Jeremy Chase Martin
    Days from application to issue
    0
    Expires
    Apr 2, 2024
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  3. Permit Mechanical HVAC Permit Finaled

    instsll one 3 ton ac w waf install one 5 ton ac w waf

    Permit
    22-22236-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $2,150
    Fees
    $111
    Contractor
    JLJ Electrical And A/C dba JLJ Construction LLC
    Days from application to issue
    7
    Expires
    Feb 1, 2023
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  4. Permit Electrical Repair / Replacement / Addition Permit Issued

    Install 100 amp sub panel with 18 circuits for lighting. Reconfigure 3 phase air handler and compressor from existing circuit.

    Permit
    22-10727-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $15,000
    Fees
    $94
    Contractor
    Arthur Joseph Hartsell
    Days from application to issue
    2
    Expires
    Oct 13, 2022
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  5. Permit Renovation (Non-Structural) Occupancy

    Reconfiguration of a portion of an existing business office area in an existing building. No addition.

    Permit
    22-03228-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $37,940
    Fees
    $310
    Contractor
    Vincent Cangiamilla
    Days from application to issue
    59
    Expires
    Oct 1, 2022
    1. Application submitted
    2. Zoning review
    3. Application review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop

  6. Permit Renovation (Structural) Permit Issued

    Demo concrete in warehouse; Remove broken 4 inch cast iron sewer line; Replace with pvc;

    Permit
    21-30317-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $20,000
    Fees
    $160
    Contractor
    Construction Solutions by Joey LLC
    Days from application to issue
    0
    Expires
    Apr 28, 2022
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  7. Permit Small Cell Installation Other

    UNIV 125 Replace existing wood utility pole with wood utility pole for small cell antenna installation S side Euphrosine St. approximately 70' from corner of S Dupre St.

    Permit
    21-22266-SMCL
    Type
    Small Cell Installation
    Work
    Small Cell Installation
    Estimated cost (applicant’s figure)
    $0
    Fees
    $1,000
    1. Application submitted

    See this permit on One Stop

    Placed here by its map location from “4090 Euphrosine St”.

  8. Permit Electrical Service / Circuit / Feeder Permit Issued

    INCREASE OF EXISTING 120/240V 3 PHASE ELECTRICAL SERVICE FROM 400A TO 600A. ENTERGY ACCOUNT #131283913 METER #8003037

    Permit
    21-11987-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $24,485
    Fees
    $280
    Contractor
    Blanchard Timothy
    Days from application to issue
    465
    Expires
    Feb 5, 2023
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

  9. Permit Electrical Repair / Replacement / Addition Permit Issued

    INSTALL 8 HIGH BAG LIGHTS 19 WALL PACK & REPALCE 200 AMP PANEL

    Permit
    15-15876-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $118
    Contractor
    Hung The Nguyen
    Days from application to issue
    20
    Expires
    Dec 16, 2015

    See this permit on One Stop

  10. Permit Electrical Service / Circuit / Feeder Permit Issued

    NEW ELECTRICAL 14-26913-RNVS

    Permit
    14-32342-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $220
    Contractor
    Hung The Nguyen
    Days from application to issue
    0
    Expires
    Apr 20, 2015

    See this permit on One Stop

  11. Permit General Mechanical Inspection Phase

    install 40-elect waf and 4 condenser unit. Thomas Mcginnis (#3164) 14-26058-Rnvn

    Permit
    14-30175-MECH
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $210
    Contractor
    Thomas Mcginnis
    Days from application to issue
    36
    Expires
    May 3, 2015

    See this permit on One Stop

  12. Permit Renovation (Structural) Occupancy

    Tenant build-out of a food distributor as per attached drawings.

    Permit
    14-26913-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $413,983
    Fees
    $2,544
    Contractor
    Timothy Terrell, Protocol Construction LLC
    Days from application to issue
    33
    Expires
    Mar 30, 2015

    See this permit on One Stop

  13. Permit Renovation (Non-Structural) Permit Issued

    roof repair

    Permit
    14-26058-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $15,000
    Fees
    $135
    Days from application to issue
    2
    Expires
    Feb 22, 2015

    See this permit on One Stop

  14. Permit Change of Address Permit Issued

    Adding address for tenant space - 4040 Euphrosine. 4001 Earhart to remain.

    Permit
    14-25492-ECOA
    Type
    Change of Address
    Work
    Change of Address
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    5
    Expires
    Feb 19, 2015

    See this permit on One Stop

  15. Permit Commercial Letter Response Pending

    RENOVATE EXISTING OFFICE/STORAGE SPACE AS PER PLANS.

    Permit
    11COM-00915
    Type
    Commercial
    Work
    NA
    Estimated cost (applicant’s figure)
    $55,000
    Fees
    $395
  16. Code enforcement Case ENVHADJ-94765SZ Closed

    The property was inspected on 03/29/1994 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 22-22236-HVAC.

  17. Code enforcement Case ENVHADJ-953397SZ Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 22-22236-HVAC.

  18. Permit General Mechanical Inspection - Completed

    rll-d-dawson-489-5566-reconnect-1-wh-ck-13807

    Permit
    08MCH-11026
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
    Contractor
    Built-In Appliance
    Days from application to issue
    5
  19. Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved

    RECONNECT

    Permit
    08ELC-13069
    Type
    Electrical Repair / Replacement / Addition
    Work
    Repair-Replacement-Addition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    Bellau Electric LLC
    Days from application to issue
    10
  20. Permit Electrical Service / Circuit / Feeder Application Acceptance - Approved

    VACANCY -ADD 2 CIRCUITS

    Permit
    07ELC-05385
    Type
    Electrical Service / Circuit / Feeder
    Work
    Service-Circuits-Feeders
    Estimated cost (applicant’s figure)
    $0
    Fees
    $66
    Contractor
    Stuart Electric Inc
    Days from application to issue
    10
  21. Permit Construction Loop Application Acceptance - Approved

    const loop

    Permit
    05ELC-09073
    Type
    Construction Loop
    Work
    Construction Loop
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    Northside Electric
    Days from application to issue
    10
  22. City record Mechanical Fuel Gas

    disconnecting gasline, and filing for a seperate gas meter.

    1. Mechanical Permit Review review Pending
    2. Mechanical Permit Review review Pending

    See this record on One Stop · checked Nov 10, 2026