Marlyville - Fontainebleau
4024 Vincennes Place is in Marlyville - Fontainebleau, zoned HU-RD1 (Older neighborhoods, two-family homes on smaller lots). It is in the Carrollton historic district under partial HDLC control, where demolition needs HDLC review. The city has 4 permits on record here; the most recent, a mechanical fuel gas permit, was filed in December 2022. 3 are still open. On this block in the past year: 20 requests to 311 and 12 calls to police.
- Zoning
- HU-RD1
- Historic district
- Carrollton (Partial control)
- National Register
- Carrollton Historic District
- Council district
- B
- Ward
- 14
- Lot size
- 12,752 sq ft
- Parcel
- 41045214
Everything on record here
4 records, newest first · 3 open
-
Permit Mechanical Fuel Gas Permit Issued
Install gas line to pool heater plus increase meter to two pounds
- Permit
- 22-36186-FGAS
- Type
- Mechanical Fuel Gas
- Work
- Mechanical Fuel Gas
- Estimated cost (applicant’s figure)
- $1,742
- Fees
- $70
- Days from application to issue
- 4
- Expires
- Jun 6, 2023
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Electrical Service / Circuit / Feeder Permit Issued
Gunite pool wiring
- Permit
- 22-30239-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,450
- Fees
- $49
- Contractor
- Douglas W. Brondum
- Days from application to issue
- 13
- Expires
- Apr 19, 2023
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Swimming Pool Permit Issued
Building a in-ground gunite pool. The pool will be built to meet or exceed all local and state codes. The equipment used will meet or exceed all local and state codes. The pool will be the correct distance in the event any electrical or cable lines are near the pool. The swimming pool equipment location shall be located at least five (5) feet from a rear lot line and three (3) feet from any side lot line, where at least two (2) feet of that distance remains open to the sky. The pool equipment will be the correct distance from the property line. An Pre-Gunite electrical inspection will be done. Pool plumbing will NOT be tied into house or city plumbing. Zoning requirements include 21.6EE, must be 4 feet from any lot line, adequate handrails and 6 ft high fence which allows 3 feet of walkway on two side or 50% of the perimeter whichever is greater will be met.
- Permit
- 22-18726-POOL
- Type
- Swimming Pool
- Work
- Swimming Pool
- Estimated cost (applicant’s figure)
- $92,000
- Fees
- $612
- Contractor
- Oasis Pool And Spas
- Days from application to issue
- 77
- Expires
- Mar 6, 2023
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
reconnect
- Permit
- 05ELC-10286
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Plauche Elec Ser Inc
- Days from application to issue
- 10