Audubon

1306 Calhoun Street is in Audubon, zoned HU-RD2 (Older neighborhoods, two-family homes mixed with single-family homes). It is in the Uptown historic district under partial HDLC control, where demolition needs HDLC review. The city has 3 permits on record here; the most recent, a residential re-roofing permit, was filed in October 2026. 1 is still open. On this block in the past year: 22 requests to 311 and 4 calls to police.

Zoning
HU-RD2
Historic district
Uptown (Partial control)
National Register
Uptown New Orleans Historic District
Council district
A
Ward
14
Lot size
5,485 sq ft
Parcel
41050680

Everything on record here

4 records, newest first · 1 open

  1. Permit Residential Re-Roofing Permit Issued

    Re-roof NOTE: Re-roofing work does not require an inspection from Safety & Permits. Instead, upload the following geotagged photos to the permit: 4 geotagged photos (one from each side) showing:   – Removal of existing roof material   – Installation of water‑intrusion‑resistant underlayment   – Installation of drip edge and flashing   – Installation of shingles or metal panels After uploading all applicable photos, email to request permit closure. Permit portal: http://onestopapp.nola.gov/

    Permit
    26-29421-ROOF
    Type
    Residential Re-Roofing
    Work
    Residential Re-Roofing
    Estimated cost (applicant’s figure)
    $0
    Fees
    $60
    Contractor
    ROBERTSON ROOFING AND SIDING, INC.
    Days from application to issue
    8
    Expires
    Apr 14, 2027
    1. Building - ReRoofing Paid
    2. Removal of Existing Roofing Material
    3. Installation of water Intrusion Resistant Underlay
    4. Installation of Drip-edge and Flashing
    5. Installation of Shingles or Metal Panels
    6. Application Submitted Complete
    7. Application submitted
    8. Application Review Complete
    9. Permit Approved Complete
    10. Sub-Permits Issued Complete
    11. Permit Issued Complete
    12. Permit Intake Complete
    13. Application review
    14. Permit approved
    15. Issue date

    See this permit on One Stop

    Placed here by an address range from “1306-1308 Calhoun St”.

  2. Permit Solar Permit Issued
    Permit
    14-00201-SOLR
    Type
    Solar
    Work
    Solar
    Estimated cost (applicant’s figure)
    $0
    Fees
    $52
    Contractor
    Bryan Charles Achary
    Days from application to issue
    18
    Expires
    Jul 21, 2014

    See this permit on One Stop

  3. Permit Renovation (Non-Structural) Permit Finaled

    Install 12 solar panels on existing roof

    Permit
    13-46051-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $13,200
    Fees
    $130
    Days from application to issue
    10
    Expires
    Jun 13, 2014

    See this permit on One Stop

  4. HDLC review HDLC COA

    remove all layers of existing roof to expose decking, Redeck entire surface with 1/2" cdx plywood decking over the existing 1" x decking, install a self-adhering 4" strip over all plywood joints in the roof decking, Install the high temperature water barrier underlayment in the valleys and other designated areas of the roof, Full Secondary Water Barrier - Install a fully adhered secondary water barrier membrane (ice and water shield) over the entire pitched roof deck, install new drip edge around entire perimeter of roof, install precut starter strips on the perimeter of the roof, Install the atlas "CLASS 4 IMPACT" limited lifetime warranted architectural shingle with premium hip/ridge cap shingles per manufacturers specifications. (see manufacturer specifications for warranty details) shingle type: atlas pinnacle pristine or equivalent, replace all lead flanges and galvanized jack and caps as needed, reuse all existing flashing, TPO Flat Roof: Remove the necessary areas of the flat roof only, Install a 1/2" hd polyiso insulation over the entire roof surface, Install new 24 gauge painted steel perimeter flashing around the outer perimeter of the flat roof, Install a 60 mil TPO membrane flat roof system according to the manufacturers specifications, Install approximately 530 sq ft of tpo walkpad in the area of the solar panels. This will cover the entire area that the solar panels currently occupy

    See this record on One Stop · checked Nov 13, 2026