Marlyville - Fontainebleau
3305 Calhoun Street is in Marlyville - Fontainebleau, zoned HU-RD1 (Older neighborhoods, two-family homes on smaller lots). It is in the Carrollton historic district under partial HDLC control, where demolition needs HDLC review. The city has 6 permits on record here; the most recent, an electrical repair / replacement / addition permit, was filed in May 2009. 6 are still open. On this block in the past year: 7 requests to 311 and 48 calls to police.
- Zoning
- HU-RD1
- Historic district
- Carrollton (Partial control)
- National Register
- Carrollton Historic District
- Council district
- A
- Ward
- 14
- Lot size
- 3,626 sq ft
- Parcel
- 41056396
Everything on record here
6 records, newest first · 6 open
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
VACANCY
- Permit
- 09ELC-07580
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Malone Electrical
- Days from application to issue
- 10
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 06ELC-22730
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Baimonte Electric
- Days from application to issue
- 10
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 06ELC-22731
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Baimonte Electric
- Days from application to issue
- 10
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 06ELC-18184
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Reaction Alarm & Electrical
- Days from application to issue
- 10
-
Permit Electrical Repair / Replacement / Addition Application Acceptance - Approved
RECONNECT
- Permit
- 06ELC-18185
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Reaction Alarm & Electrical
- Days from application to issue
- 10
-
Permit General Mechanical Inspection - Completed
space heater
- Permit
- 04MCH-04811
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $20
- Contractor
- C.N.Finley Inc
- Days from application to issue
- 5