Bywater

3000 Burgundy Street is in Bywater, zoned HMR-3 (Marigny, Tremé and Bywater single- and two-family homes, with some small multi-family buildings). It is in the Bywater historic district under full HDLC control, so most exterior changes need approval first. The city has 7 permits on record here; the most recent, an HDLC COA permit, was filed in October 2024. 6 are still open. There were 2 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 30 requests to 311 and 9 calls to police.

Zoning
HMR-3
Historic district
Bywater (Full control)
National Register
Bywater Historic District
Council district
C
Ward
9
Lot size
3,080 sq ft
Parcel
41066200

Everything on record here

9 records, newest first · 6 open

  1. Permit HDLC COA Permit Issued

    Replace one section deteriorated wood siding with smooth finish hardiplank and paint

    Permit
    24-29626-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    21
    Expires
    Apr 23, 2025

    See this permit on One Stop

  2. Permit Renovation (Non-Structural) Permit Issued

    1. Deteriorated sills – repair/replace all damaged/deteriorated wood windowsills to match the existing condition 2. Deteriorated or missing porch decking – at balconies along Montegut – repair/replace damaged/deteriorated decking with new wood tongue-and-groove deck boards to match existing 3. Missing or deteriorated weatherboards – at left side, and particularly at right side – repair/replace damaged/deteriorated wood weatherboards with new wood or (SMOOTH) finish Hardie weatherboards to match existing in size/exposure 4. Missing or deteriorated soffits and/or fascia - repair/replace all damaged/ deteriorated soffits and fascia to match the existing condition 5. Vegetation growing on building – all vegetation should be carefully removed (ensuring removal process does not compromise integrity of structural members or building envelope). It looks like most of the vegetation is at the base of the building. If you would like to keep plants at this area you can consider moveable planter pots – however, vegetation on the building impacts the masonry and mortar and compromises its integrity which can also allow moisture to enter the building or to accelerate the deterioration. 6. Deteriorated masonry and/or stucco – appears to be for deteriorated mortar conditions, some areas of missing brick, and issues with water being allowed to run down the wall which may be accelerating the masonry deterioration, for example. Areas of missing mortar should be repaired with appropriate mor

    Permit
    24-29626-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $39,150
    Fees
    $480
    Days from application to issue
    47
    Expires
    May 13, 2025
    1. Application submitted
    2. Zoning review
    3. Application review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  3. Permit HDLC COA Permit Finaled

    Remove old roof and replace

    Permit
    21-10562-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Oct 16, 2021

    See this permit on One Stop

  4. Permit Renovation (Non-Structural) Application Accepted

    Remove old roof and replace

    Permit
    21-10562-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $8,500
    Fees
    $158
    Contractor
    Schwander Hutchinson Roofing, Inc.
    1. Application submitted

    See this permit on One Stop

  5. Code enforcement Case ENVHADJ-20011263HB Closed

    The property was inspected on 11/20/2000 with a finding of "Complete". The file was subsequently closed.

    1. Inspection: Inspection Complete

    The city links this case to permit 24-29626-HDLC.

  6. Code enforcement Case ENVHADJ-96102 Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 24-29626-HDLC.

  7. Permit Repair Application Acceptance - Approved No Review

    REPAIR WINDOWS, ROOF, AND INSTALL HVAC AS PER HDLC COA #B417.

    Permit
    05BLD-00410
    Type
    Repair
    Work
    Repair
    Estimated cost (applicant’s figure)
    $11,000
    Fees
    $158
    Days from application to issue
    5
  8. Permit General Mechanical Inspection - Completed

    gas warm air furnace and 5ton ac unit. steven . check #1863.

    Permit
    05MCH-00737
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $73
    Contractor
    Spiers A/C & Htg.
    Days from application to issue
    5
  9. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT SINGLE-FAMILY DWELLING INSTALL NEW GAS WATER HEATER AND GAS LINE. DANIEL LAMBERT 866-7162

    Permit
    M01000541
    Type
    Mechanical
    Days from application to issue
    1

    Placed here by its map location from “3006 BURGUNDY ST UNIT B”.