Desire Area

3250 Industry Street is in Desire Area, zoned S-B2 (Newer neighborhoods, walkable business corridors). The city has 7 permits on record here. 1 is still open. On this block in the past year: 0 requests to 311 and 18 calls to police.

Zoning
S-B2
Historic district
None
Council district
D
Ward
9
Lot size
4,813 sq ft
Parcel
41091905

Everything on record here

7 records, newest first · 1 open

  1. Permit Permit Permit Expired Due to Inactivity

    Start: 3250 Industry St. Left on Florida Ave to Desire. St. Right on Desire St. Pick up ("9th WARD ROLLERS S&P CLUB). Continue down Desire St. to (1612 Desire St.) X (3403 N. Claiborne Ave.) --STOP!-- "OTF S&P CLUB" 30 mins. Turn right onto N. Claiborne Ave. over the bridge to Franklin Ave.,) Left on Franklin Ave. Proceed to (1112 Franklin Ave.) --STOP-- "Keeping It Real S&P Club." Continue down Franklin Ave. to St. Claude, Proceed St. Claude to (3100 Clouet St.) --STOP-- "9 X's Kids" Continue down St. Claude to Desire St. Take Left onto Desire St. Proceed Desire St. back to (3403 N. Claiborne Ave.) --STOP-- "Family Ties S&P Club." Continue Desire St. to Florida Ave., Left on Florida Ave. to Piety St. Merge Right of Piety St. onto Johnny Jackson Blvd. Carry out Johnny Jackson Blvd to Benefit, make left back onto (3144 Johnny Jackson Blvd,) --DISBAND-- non payment email sent 4-7-2026

    Permit
    26-07618-SPMA
    1. Application submitted
    2. Application review
  2. Permit Electrical Service / Circuit / Feeder Meter Release

    Add second 200 amp meter for fire pump

    Permit
    22-34445-SERV
    Type
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $6,000
    Fees
    $103
    Days from application to issue
    1
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    Placed here by the building address from “3250 Industry St FIRE PUMP”.

  3. Permit Mechanical HVAC Permit Finaled

     Furnish and install Equipment Packaged Rooftop Electric Cooling Unit, The following items are included: Voltage: 460/3/60 Unit Size: (1) 20 Tons and (1) 25 Tons Packaging Options: Standard Carrier Package Refrigeration Systems Options: Two-Stage Cooling Models with Round Tube/Plate Fin Coils Service Options: Unpowered Convenience Outlet Indoor Motor Options: High Static Indoor Fan Motor/Horizontal Supply, Return Air Flow Coil Protection Options: Round Tube Plate Fin (RTPF) Al/Cu Condenser Coil, Al/Cu Evaporator Coil with Louvered Hail Guard Sensor Options: Return Air Smoke Detector Base Unit Controls: RTU Open Multi-Protocol Controller. Connects the rooftop to an existing Building Automation System  Furnish and install controls  Furnish and install ductwork  Furnish and install (55) grills/registers/diffusers  Furnish and install (5) gravity backdraft dampers to be mounted in exhaust duct.  Furnish and install (14) manual dampers  Furnish and install (2) louvers with finish  Furnish and install grease duct  Install customer provided hood  Furnish and install (2) electrical wall heaters with thermostats  Furnish and install (5) Greenheck fans EF-1 thru EF-4 with speed controls  Startup HVAC equipment  Provide air balancing

    Permit
    22-08334-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $183,000
    Fees
    $181
    Days from application to issue
    21
    Expires
    Oct 11, 2022
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  4. Permit Electrical Service / Circuit / Feeder Permit Finaled

    New Construction 20-25568 NEWC

    Permit
    21-20342-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $762
    Contractor
    Chester Arnell Williams
    Days from application to issue
    398
    Expires
    Feb 16, 2023
    1. Application submitted
    2. Application review
    3. First inspection
    4. Permit approved
    5. Issue date

    See this permit on One Stop

  5. Permit Construction Loop Permit Finaled

    CONSTRUCTION LOOP 20-25568-NEWC

    Permit
    21-09815-LOOP
    Type
    Construction Loop
    Work
    Construction Loop
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40
    Contractor
    Chester Arnell Williams
    Days from application to issue
    1
    Expires
    Oct 8, 2021
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  6. Permit Change of Address Permit Issued

    20-25568-NEWC entrance to project ADD 3250 Industry St

    Permit
    21-04646-ECOA
    Type
    Change of Address
    Work
    Change of Address
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Aug 18, 2021
    1. Application submitted
    2. Permit approved
    3. Issue date

    See this permit on One Stop

  7. Permit New Construction Occupancy

    Desire-Florida Multi-Service Center. A City of New Orleans owned public neighborhood community center per plans. Note: On 2-18-2021 the address was changed from 2700 Louisa St to 3250 Industry St.

    Permit
    20-25568-NEWC
    Type
    New Construction
    Work
    New Construction
    Estimated cost (applicant’s figure)
    $4,310,000
    Fees
    $26,235
    Contractor
    NFT Group LLC
    Days from application to issue
    340
    Expires
    Sep 23, 2021
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date
    7. First inspection

    See this permit on One Stop