Bayou St. John

3017 Toulouse Street is in Bayou St. John, zoned HU-RD2 (Older neighborhoods, two-family homes mixed with single-family homes). It is in the Parkview historic district under partial HDLC control, where demolition needs HDLC review. The city has 12 permits on record here; the most recent, a change of address permit, was filed in September 2022. 7 are still open. A demolition permit was filed in September 2008. There were 3 past code enforcement cases, the latest in April 2009, all closed. On this block in the past year: 6 requests to 311 and 10 calls to police.

Zoning
HU-RD2
Historic district
Parkview (Partial control)
National Register
Parkview Historic District
Council district
A
Ward
5
Lot size
2,841 sq ft
Parcel
41129070

Everything on record here

15 records, newest first · 7 open

  1. Permit Change of Address Permit Issued

    Owner Initiated KEEP 3017 Toulouse St (AM10225288, A354588) RETIRE 3019 Toulouse St

    Permit
    22-28717-ECOA
    Type
    Change of Address
    Work
    Change of Address
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Mar 22, 2023
    1. Application submitted
    2. Permit approved
    3. Issue date

    See this permit on One Stop

    Placed here by an address range from “3017-3019 Toulouse St”.

  2. Permit Mechanical HVAC Permit Finaled

    Replace existing system with new 3 ton horizontal electric heat HVAC system

    Permit
    20-28962-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $5,990
    Fees
    $65
    Days from application to issue
    1
    Expires
    Nov 22, 2020
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  3. Permit Mechanical HVAC Permit Cancelled

    Replace existing system with new 3 ton horizontal electric heat HVAC system

    Permit
    20-27958-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $5,990
    Fees
    $65
    1. Application submitted

    See this permit on One Stop

  4. Permit Electrical Repair / Replacement / Addition Permit Finaled

    Cutting wires repair. All wires were cutting in the attic. 20-21005-RNVS

    Permit
    20-27282-ERPR
    Type
    Electrical Repair / Replacement / Addition
    Work
    Electrical Repair / Replacement / Addition
    Estimated cost (applicant’s figure)
    $4,500
    Fees
    $546
    Contractor
    Ordonez Andres Andres Jaime
    Days from application to issue
    16
    Expires
    Nov 21, 2020
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  5. Permit Renovation (Structural) Occupancy

    Renovation as per plans.

    Permit
    20-21005-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $0
    Fees
    $120
    Days from application to issue
    27
    Expires
    Oct 1, 2020
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  6. Permit Certificate of Occupancy Certificate Issued w/Meter

    NEW CONSTRUCTION OF A 1 STORY 1224 SF (1080 SF LIVABLE AREA,144 SF PORCH) SINGLE PER PLANS. FY ave = 6' APPROVED TEMPORARY USE AND OCCUPANCY VALID UNTIL AUGUST 31, 2011. SEE PERMIT 10BLD-05002

    Permit
    11OCC-00371
    Type
    Certificate of Occupancy
    Work
    NA
    Estimated cost (applicant’s figure)
    $60
    Fees
    $60
  7. Permit Electrical Service / Circuit / Feeder Permit Issuance - Active

    NEW CONSTRUCTION- 10BLD-05002

    Permit
    11ELC-01860
    Type
    Electrical Service / Circuit / Feeder
    Work
    Service-Circuits-Feeders
    Estimated cost (applicant’s figure)
    $0
    Fees
    $114
    Contractor
    Total Control
    Days from application to issue
    0
  8. Permit General Mechanical Inspection - Completed

    INSTALL ELEC WAF AND A\C. *10BLD-05002/3rd party inspector-james mohaamad/ MCCLAIN (#1335)

    Permit
    11MCH-01408
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $65
    Contractor
    Tmb Services LLC
    Days from application to issue
    0
  9. Permit Construction Loop Permit Issuance - Active

    TEMP POLE- 10BLD-05002

    Permit
    11ELC-01186
    Type
    Construction Loop
    Work
    Construction Loop
    Estimated cost (applicant’s figure)
    $0
    Fees
    $40
    Contractor
    Total Control
    Days from application to issue
    0
  10. Permit New Construction Certificate of Occupancy - Issued No Meter

    NEW CONSTRUCTION OF A 1 STORY 1224 SF (1080 SF LIVABLE AREA,144 SF PORCH) SINGLE PER PLANS. FY ave = 6'

    Permit
    10BLD-05002
    Type
    New Construction
    Work
    New
    Estimated cost (applicant’s figure)
    $124,744
    Fees
    $810
    Days from application to issue
    20
  11. Permit General Mechanical Certificate Of Completion - Issued No Meter

    rll-j-corcoran-259-3719-reconnect-1-wh-ck-5844

    Permit
    09MCH-05518
    Type
    General Mechanical
    Work
    General Mechanical
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
    Contractor
    Mr. C's Plumbing Inc.
    Days from application to issue
    5
  12. Code enforcement Case ENVHADJ-20014467HB Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 22-28717-ECOA.

  13. Code enforcement Case ENVHADJ-20041688EH Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 22-28717-ECOA.

  14. Code enforcement Case ENVHADJ-962825 Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 22-28717-ECOA.

  15. Permit Demolition Inspection - Completed No Requirements

    DEMOLISH DOUBLE FAMILY HOUSE TO GRADE. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL DEBRIS WITHIN 72 HOURS OF COMPLETION. PROOF OF DISPOSAL REQUIRED AT TIME OF FINAL INSPECTION. SEPARATE PERMIT REQUIRED FROM SEWERAGE AND WATER BOARD TO CAP SEWER LINES AND REMOVE WATER METERS. WORK ORDER 2448

    Permit
    08BLD-06907
    Type
    Demolition
    Work
    Demolition
    Estimated cost (applicant’s figure)
    $0
    Fees
    $125
    Days from application to issue
    5