Leonidas

1612 South Carrollton Avenue is in Leonidas, zoned HU-RD2 (Older neighborhoods, two-family homes mixed with single-family homes). It is in the Carrollton Avenue historic district under full HDLC control, so most exterior changes need approval first. The city has 5 permits on record here; the most recent, an HDLC COA permit, was filed in September 2026. 2 are still open. On this block in the past year: 18 requests to 311 and 6 calls to police.

Zoning
HU-RD2
Historic district
Carrollton Avenue (Full control)
National Register
Carrollton Historic District
Council district
A
Ward
17
Lot size
10,388 sq ft
Parcel
41133233

Everything on record here

5 records, newest first · 2 open

  1. Permit HDLC COA Other

    Complete Fortified roof replacement. 1. Removal and Disposal: Remove, haul, tear-off, and dispose of one layer of the existing roof. 2. Roof Deck Nailing: Nail the existing roof deck with 8d ring-shank nails spaced at 4 inches on center per F-RR-3 standards. 3. Deck Sealing: Install deck tape on decking seams across the entire roof to enhance sealing. 4. Waterproofing: Install Ice & Water Barrier in valleys and around openings. 5. Underlayment: Install synthetic underlayment for additional moisture and wind-driven rain protection. This creates a bond break between the shingles and the Ice-and-Water shield. 6. Drip Edge: Replace the existing drip edge with a new fortified drip edge that extends 1/2 inch below the sheathing and a minimum of 2 inches back onto the roof. 7. Starter Shingles: Install double-sided starter shingle rolls along the entire perimeter of the roof. 8. Shingles: Use Owens Corning™ DURATION® Series Shingles, featuring SureNail® Technology, 9. Hip & Ridge Shingles: Install Owens Corning™ PROEDGE® Hip & Ridge Shingles. 10. GAF power vents and eave vents. Louver vents will be removed. 11. Bullet Boots 12. Flashing: 13. New Hecker V tiles, we will reuse the tiles with the pattern as starter/finishing tiles. 14. Modified Bitumen Replacement on second story

    Permit
    26-25817-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    6
    Expires
    Mar 9, 2027
    1. Permit Case Created Complete
    2. Information Needed Complete
    3. Completeness Review Complete
    4. Certificate Drafted Complete
    5. Permit Issued Complete
    6. Inspection Requested Complete
    7. Final HDLC Under Review

    See this permit on One Stop

  2. Permit Residential Re-Roofing Permit Issued

    Complete Fortified roof replacement PLEASE NOTE: Re-roofing permits DO NOT require an inspection from Safety and Permits, instead please upload the following photos to this permit PHOTOS REQUIRED 4 geotagged photos (one from each side) showing: -Removal of existing roof material -Installation of water intrusion resistant underlayment -Installation of the drip-edge and flashing -Installation of shingles or metal panels  Once all applicable photos have been uploaded to the permit, please email requesting permit closure. http://onestopapp.nola.gov/

    Permit
    26-25817-ROOF
    Type
    Residential Re-Roofing
    Work
    Residential Re-Roofing
    Estimated cost (applicant’s figure)
    $0
    Fees
    $60
    Contractor
    The Roof Division LLC
    Days from application to issue
    9
    Expires
    Mar 11, 2027
    1. Building - ReRoofing Paid
    2. Removal of Existing Roofing Material
    3. Installation of water Intrusion Resistant Underlay
    4. Installation of Drip-edge and Flashing
    5. Installation of Shingles or Metal Panels
    6. Application Submitted Complete
    7. Application submitted
    8. Application Review Complete
    9. Permit Approved Complete
    10. Sub-Permits Issued Complete
    11. Permit Issued Complete
    12. Permit Intake Complete
    13. Application review
    14. Permit approved
    15. Issue date

    See this permit on One Stop

    Placed here by an address range from “1612-1614 S Carrollton Ave”.

  3. Permit Mechanical Fuel Gas Permit Finaled

    Gas out 6 months.

    Permit
    22-12614-FGAS
    Type
    Mechanical Fuel Gas
    Work
    Mechanical Fuel Gas
    Estimated cost (applicant’s figure)
    $350
    Fees
    $30
    Days from application to issue
    2
    Expires
    Oct 29, 2022
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date
    5. First inspection

    See this permit on One Stop

  4. Permit Mechanical Fuel Gas Permit Finaled

    ajm311, ck r106893272937 dean 485-9226 meter

    Permit
    16-27730-FGAS
    Type
    Mechanical Fuel Gas
    Work
    Mechanical Fuel Gas
    Estimated cost (applicant’s figure)
    $0
    Fees
    $30
    Contractor
    Dean Walters
    Days from application to issue
    0
    Expires
    Feb 23, 2017

    See this permit on One Stop

  5. Permit Renovation (Non-Structural) Other

    gas off 6 months

    Permit
    16-26792-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $400
    Fees
    $65

    See this permit on One Stop