St. Claude
1030 Lesseps Street is in St. Claude, zoned HMC-2 (Marigny, Tremé and Bywater busier commercial streets). It is in the Bywater historic district under full HDLC control, so most exterior changes need approval first. The city has 20 permits on record here; the most recent, a mechanical fuel gas permit, was filed in June 2025. 16 are still open. A demolition permit was filed in May 2009. On this block in the past year: 1 request to 311 and 24 calls to police.
- Zoning
- HMC-2
- Historic district
- Bywater (Full control)
- National Register
- Bywater Historic District
- Council district
- C
- Ward
- 9
- Lot size
- 33,450 sq ft
- Parcel
- 41174853
Everything on record here
20 records, newest first · 16 open
-
Permit Mechanical Fuel Gas Other
INSTALL NEW 1" GAS LINE FOR 25 KW GENERATOR 300,000 BTU.
- Permit
- 25-19359-FGAS
- Type
- Mechanical Fuel Gas
- Work
- Mechanical Fuel Gas
- Estimated cost (applicant’s figure)
- $7,500
- Fees
- $62
- Days from application to issue
- 32
- Expires
- Jan 28, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Permanent Generator Permit Issued
MOUNT/INSTALL 125 AMP A.T.S WITH ONE 15 AMP CIRCUIT FOR BATTERY CHARGER.
- Permit
- 25-18507-EGEN
- Type
- Permanent Generator
- Work
- Permanent Generator
- Estimated cost (applicant’s figure)
- $12,500
- Fees
- $81
- Contractor
- Joseph Anthony Gabriel
- Days from application to issue
- 14
- Expires
- Jan 1, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit HDLC COA Permit Issued
INSTALL 25KW GENERATOR
- Permit
- 25-13565-HDLC
- Type
- HDLC COA
- Work
- HDLC COA
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 9
- Expires
- Nov 14, 2025
-
Permit Accessory Structure Permit Issued
INSTALL 25KW GENERATOR
- Permit
- 25-13565-ACCS
- Type
- Accessory Structure
- Work
- Accessory Structure
- Estimated cost (applicant’s figure)
- $12,500
- Fees
- $278
- Contractor
- Joseph Anthony Gabriel
- Days from application to issue
- 33
- Expires
- Dec 6, 2025
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Renovation (Non-Structural) Other
INSTALL 20KW NAT GAS GENERATOR
- Permit
- 25-13563-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $12
- Fees
- $188
- Application submitted
-
Permit Plumbing Permit Permit Issued
SEWER REPAIR
- Permit
- 25-08604-PLMB
- Type
- Plumbing Permit
- Work
- Plumbing Permit
- Estimated cost (applicant’s figure)
- $0
- Fees
- $100
- Contractor
- Jamal Donnell Every
- Days from application to issue
- 1
- Expires
- Sep 20, 2025
-
Permit Street Cut Other
2 - 6 foot by 6 foot cuts to install new HP gas main and gas service.
- Permit
- 21-22464-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $364
- Contractor
- Entergy Gas Co.
- Days from application to issue
- 10
- Expires
- Feb 13, 2022
-
Permit HDLC COA Permit Issued
Remove & replace existing plate letters and install new with backer panel.
- Permit
- 19-33571-HDLC
- Type
- HDLC COA
- Work
- HDLC COA
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 0
- Expires
- Apr 23, 2020
-
Permit Attached Sign Permit Issued
Remove & replace existing plate letters and install new with backer panel. Remove & replace existing panel and install new panel.
- Permit
- 19-33571-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $353
- Contractor
- Capital Signs & Awnings LLC
- Days from application to issue
- 21
- Expires
- May 12, 2020
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Mechanical HVAC Permit Finaled
REMOVE & REPLACE (1) 1.5 TON WITH 18,000 BTUS MINI SPLIT - NO HEAT.
- Permit
- 19-11790-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $5,578
- Fees
- $65
- Days from application to issue
- 4
- Expires
- Oct 16, 2019
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Mechanical Annual Fee Invoiced
DAUGHTERS OF CHARITY HEALTH CLINIC//(07/07/2010)ANN ELEV INSP.//#941-6041
- Permit
- 10MCH-06496
- Type
- Mechanical
- Work
- Moving Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $55
-
Permit Certificate of Occupancy Certificate Issued No Meter
This Temporary Certificate of Occupancy is valid for a period of thirty (30) days as per State Fire Marshal Office. Building Permit 09COM-00890
- Permit
- 10OCC-00317
- Type
- Certificate of Occupancy
- Work
- NA
- Estimated cost (applicant’s figure)
- $2,000,000
- Fees
- $125
-
Permit General Mechanical Certificate Of Completion - Issued No Meter
INSTALL 3-ELEC WAF,ELEC W\H AND 3-SPLIT A\C SYSTEM. C. ROBERT BERNHARD (#1793) *09COM-00467
- Permit
- 10MCH-04284
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $0
- Fees
- $388
- Contractor
- Bernhard Mech Contrs.
- Days from application to issue
- 5
-
Permit Electrical Service / Circuit / Feeder Application Acceptance - Approved
REWIRE- 09COM-00890
- Permit
- 10ELC-00550
- Type
- Electrical Service / Circuit / Feeder
- Work
- Service-Circuits-Feeders
- Estimated cost (applicant’s figure)
- $0
- Fees
- $475
- Contractor
- L Davis Elecric Ser
- Days from application to issue
- 10
-
Permit Electrical Service / Circuit / Feeder Application Acceptance - Approved
CIRCUITS- 09COM-01320
- Permit
- 09ELC-17766
- Type
- Electrical Service / Circuit / Feeder
- Work
- Service-Circuits-Feeders
- Estimated cost (applicant’s figure)
- $0
- Fees
- $45
- Contractor
- K Lasalle Construction
- Days from application to issue
- 10
-
Permit Renovation (Non-Structural) Application Acceptance - Approved w/Plan Review
Masonry repair and cleaning to existing building as per Plans & HDLC C of A#: PK5041.
- Permit
- 09COM-01320
- Type
- Renovation (Non-Structural)
- Work
- NA
- Estimated cost (applicant’s figure)
- $350,000
- Fees
- $3,225
- Contractor
- Blitch Knevel Architects,Inc
- Days from application to issue
- 14
-
Permit Change of Use State Fire Marshal Approval - Approved
Converting a school into a clinic as per plans. Electrical,Hvac and Plumbing.
- Permit
- 09COM-00890
- Type
- Change of Use
- Work
- NA
- Estimated cost (applicant’s figure)
- $2,000,000
- Fees
- $18,075
- Contractor
- Blitch Knevel Architects,Inc
- Days from application to issue
- 21
-
Permit Construction Loop Application Acceptance - Approved
TEMP POLE
- Permit
- 09ELC-10087
- Type
- Construction Loop
- Work
- Construction Loop
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- All Star Electric,Inc.
- Days from application to issue
- 10
-
Permit Demolition Application Acceptance - Approved No Review
Demolition to existing building as per plans and HDLC CofA#: PK4380.
- Permit
- 09COM-00466
- Type
- Demolition
- Work
- NA
- Estimated cost (applicant’s figure)
- $202,000
- Fees
- $-555
- Days from application to issue
- 6
-
Permit Renovation (Structural) Application Acceptance - Approved No Review
Repair/Replace roof as needed as per HDLC C of A PK4380. All replacement and repair material shall match existing.
- Permit
- 09COM-00467
- Type
- Renovation (Structural)
- Work
- NA
- Estimated cost (applicant’s figure)
- $229,500
- Fees
- $188
- Days from application to issue
- 5