Central Business District
1000 Howard Avenue is in Central Business District, zoned CBD-1 (Downtown core, high-density offices, hotels, housing and entertainment). The city has 51 permits on record here; the most recent, an attached sign permit, was filed in July 2026. 27 are still open. There were 2 past code enforcement cases, the latest in May 2024, all closed. It has an active short-term rental license (Lodging Exempt from STR Regulation). On this block in the past year: 2 requests to 311 and 57 calls to police.
- Zoning
- CBD-1
- Historic district
- None
- Council district
- B
- Ward
- 2
- Lot size
- 35,350 sq ft
- Parcel
- 41181084
Everything on record here
54 records, newest first · 28 open
-
Short-term rental Lodging Exempt from STR Regulation license Active
- License
- 26-XSTR-17401
- Type
- Lodging Exempt from STR Regulation
- Issued
- Aug 5, 2026
-
Permit Attached Sign Other
Interior marquee was changed on and existing sign. The sign itself was not modified or adjusted
- Permit
- 26-22250-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $250
- Contractor
- Pro Signs & Graphics
- Days from application to issue
- 5
- Expires
- Feb 4, 2027
- Sign Paid
- Sign Operation Paid
- Sign Review - Zoning Paid
- Application Submitted Complete
- Application submitted
- Zoning Complete
- Plan Review Complete
- Application Review Complete
- Zoning Review Complete
- Permit Intake Complete
- Application review
- Zoning review
- Plan Review Complete
- Permit Approved Complete
- Permit Issued Complete
- Plan review
- Permit approved
- Issue date
- Sign Passed
- First inspection
- Inspections Finaled Complete
- Certificate of Completion Complete
-
Permit Mechanical Fuel Gas Other
New gas lines installed for water heater dryer and pool heater
- Permit
- 26-14486-FGAS
- Type
- Mechanical Fuel Gas
- Work
- Mechanical Fuel Gas
- Estimated cost (applicant’s figure)
- $3,000
- Fees
- $60
- Days from application to issue
- 6
- Expires
- Nov 19, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Plumbing Permit Other
Running new pvc main for (6) 6" pvc storm drain risers to catch basin connected to storage tank under parking lot.
- Permit
- 26-12422-PLMB
- Type
- Plumbing Permit
- Work
- Plumbing Permit
- Estimated cost (applicant’s figure)
- $0
- Fees
- $50
- Contractor
- BRETT JOHNSON
- Days from application to issue
- 4
- Expires
- Oct 27, 2026
-
Permit Plumbing Permit Other
Underground sewer and domestic water rough-in with lift station. Top out rough-in and trim out.
- Permit
- 26-12405-PLMB
- Type
- Plumbing Permit
- Work
- Plumbing Permit
- Estimated cost (applicant’s figure)
- $0
- Fees
- $100
- Contractor
- BRETT JOHNSON
- Days from application to issue
- 11
- Expires
- Nov 4, 2026
-
Permit Renovation (Non-Structural) Application Accepted
Storm Drain connection on risers in basement to catch basis that connects to storage tank underneath parking lot.
- Permit
- 26-12271-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $410,000
- Fees
- $2,520
- Application submitted
-
Permit New Construction Application Accepted
Underground sewer and domestic water rough-in with lift station.
- Permit
- 26-12249-NEWC
- Type
- New Construction
- Work
- New Construction
- Estimated cost (applicant’s figure)
- $28,000
- Fees
- $260
- Application submitted
-
Permit Renovation (Non-Structural) Application Accepted
Underground rough-in with lift station.
- Permit
- 26-11698-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $28,000
- Fees
- $260
- Contractor
- C. Roberds General Contractors
- Application submitted
-
Permit Electrical Service / Circuit / Feeder Other
Installation of 200kW Temporary generator for the facility.
- Permit
- 26-07108-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $0
- Fees
- $160
- Contractor
- Jeremy Chase Martin
- Days from application to issue
- 33
- Expires
- Oct 13, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Mechanical Fuel Gas Other
Gas line ran for generator -
- Permit
- 26-05057-FGAS
- Type
- Mechanical Fuel Gas
- Work
- Mechanical Fuel Gas
- Estimated cost (applicant’s figure)
- $7,000
- Fees
- $70
- Contractor
- Katawan Vashon Fletcher, Sr.
- Days from application to issue
- 51
- Expires
- Oct 14, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Accessory Structure Application Accepted
Accessory structure for 1000 Howard Hotel pickleball amenity including pickleball courts, bathrooms, and associated MEP. Stormwawater updated from permit 22-27469 RNVS Full Stormwaer Review on this permit
- Permit
- 25-31755-ACCS
- Type
- Accessory Structure
- Work
- Accessory Structure
- Estimated cost (applicant’s figure)
- $1,000,000
- Fees
- $6,060
- Application submitted
-
Permit Swimming Pool In Review
in ground swimming pool
- Permit
- 25-24606-POOL
- Type
- Swimming Pool
- Work
- Swimming Pool
- Estimated cost (applicant’s figure)
- $73,300
- Fees
- $504
- Contractor
- Young Construction Group
- Application submitted
- Application review
- Zoning review
-
Permit Moving Equipment Other
Modernization of Three ( 3 ) Passenger Elevators
- Permit
- 25-22760-MOVG
- Type
- Moving Equipment
- Work
- Moving Equipment
- Estimated cost (applicant’s figure)
- $0
- Fees
- $9,055
- Contractor
- Pinnacle Elevator
- Days from application to issue
- 1
- Expires
- Jan 29, 2026
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Mechanical HVAC Other
Subcontractor shall provide all labor, materials, equipment, and services to supply and install a complete and comprehensive mechanical system to include but not limited to permitting, tests & inspections, OAUs, Heat Pumps, Piping & Coils, Gauges, Ductwork, Insulations, fittings & valves, starters, low voltage and/or control wiring & connections, fire dampers, mini-splits, grilles & registers, cassettes, mechanical louvers, exhaust fans, roof curbs for equipment, mech. equipment stands, thermostats, new MERV 8 filters at turnover, wall penetration sleeves, elevator & stair pressurization fans, dryer vent cap, and box controllers per contract documents. Note Owner Supplied Equipment will be Heat Pumps, Outside Air Heat Pump Units, Outside Air Units, Ductless Air Handling Units.
- Permit
- 25-03301-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $2,223,943
- Fees
- $4,755
- Days from application to issue
- 48
- Expires
- Sep 20, 2025
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Plumbing Permit Other
Subcontract shall provide all labor, materials, testing, and equipment to supply and install a complete plumbing system to include but not limited to permits & fees, inspections, layout, pumps & controllers, valves & gauges, all piping types, hangers, insulation, fixtures, cleanouts, roof vents, drains, lint trap assembly, washer
- Permit
- 25-00761-PLMB
- Type
- Plumbing Permit
- Work
- Plumbing Permit
- Estimated cost (applicant’s figure)
- $0
- Fees
- $9,770
- Contractor
- Allen Raimer, Jr
- Days from application to issue
- 55
- Expires
- Sep 20, 2025
-
Permit Electrical Service / Circuit / Feeder Other
Maintain temporary power for construction phase. REWORK existing electrical panels as needed. Repurpose existing 2,000A main switchboard. Repurpose (2) existing 800A distribution panelboards. Furnish, install, and update new electrical distribution. Furnish and install new panels, transformers, disconnect switches throughout the building to for electrical infrastructure. The gear package will be inclusive of aluminum bussing and transformer windings. Feeders 150A and larger will utilize aluminum conductors with proper terminations. Utilize armored cable feeders from DP panels to TP panels. Furnish and install light fixtures in public areas, corridors and back of house. Furnish and install light fixtures in guestrooms. Furnish and install lighting controls and devices. Furnish and install exterior LED ‘Halo’ around the 3 rd floor and 12th floor roof. Furnish and install electrical devices and circuitry. Furnish and install electrical connections to kitchenette equipment. - i.e., dishwashers, refrigerators, stoves, and microwaves Furnish and install single-point electrical connections to HVAC equipment. Furnish and install single-point electrical connections to Pool/Whirlpool equipment. Utilize MC cabling for ALL branch circuitry, in lieu of conduit and wire. Furnish and install fire alarm back box with conduit stub to conduit system. Furnish and install camera back box with conduit stub to accessible ceili
- Permit
- 25-00755-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,263,829
- Fees
- $640
- Contractor
- Jeremy Chase Martin
- Days from application to issue
- 61
- Expires
- Sep 10, 2025
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Code enforcement Case 24-04722-MPM Closed
A hearing was held on 02/10/2025 with a result of "Reset: Office Closure".
- Inspection: Inspection Violation: No WIP
- Violation: 157 Sanitation
- Violation: 158 Grading
- Violation: 160 Weeds and Plant Growth
- Violation: 162 Exhaust Vents
- Violation: 163 Accessory Structures
- Violation: 163 Fences and Walls
- Violation: 171 Exterior Walls
- Violation: 176 Stairways
- Violation: 179 Windows
- Violation: 181 Doors
- Inspection: Posting of Hearing Notice Violation: No WIP
- Hearing: Initial Hearing Reset: Work In Progress
- Inspection: Reinspection Violation: No WIP
- Inspection: Inspection Violation: WIP
- Hearing: Reset Hearing Guilty
- Hearing: Reset Hearing Reset: Office Closure
The city links this case to permit 26-22250-SATT.
-
Permit Renovation (Non-Structural) Permit Issued
Equipment upgrades at an existing rooftop wireless facility, no changes to the height of the facility or the compound are proposed.
- Permit
- 24-08438-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $35,000
- Fees
- $295
- Contractor
- Mastec Network Solutions Inc
- Days from application to issue
- 54
- Expires
- Nov 15, 2024
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Electrical Service / Circuit / Feeder Other
INSTALL 200A SERVICE FOR EXISTING AT&T SITE
- Permit
- 23-27226-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $10,973
- Fees
- $103
- Contractor
- Wesley Harold Brown Jr.
- Days from application to issue
- 15
- Expires
- Apr 19, 2024
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Moving Equipment Other
Installation of Man / Material Hoist For Building Renovation
- Permit
- 23-18122-MOVG
- Type
- Moving Equipment
- Work
- Moving Equipment
- Estimated cost (applicant’s figure)
- $0
- Fees
- $300
- Contractor
- Garrison Builders
- Days from application to issue
- 0
- Expires
- Jan 5, 2024
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Interior Demolition Inspection Phase
Interior demolition at 1000 Howard Ave. No use or occupancy. Renovation requires separate permit.
- Permit
- 23-09622-DEMI
- Type
- Interior Demolition
- Work
- Interior Demolition
- Estimated cost (applicant’s figure)
- $348,550
- Fees
- $2,154
- Contractor
- Garrison Builders, LLC
- Days from application to issue
- 28
- Expires
- Nov 9, 2023
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit Renovation (Structural) Other
RENOVATION OF AN EXISTING OFFICE BUILDING INTO A 39 UNIT, 195 BED HOTEL. ALL WORK TO BE DONE AS PER PLANS. *<BBSA APPROVAL OF LOWEST FLOOR>* FINAL INSPECTION VERIFY that they relocated all critical equipment from the basement to the first floor above the BFE to meet the floodplain BFE requirement.
- Permit
- 22-27469-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $18,813,436
- Fees
- $112,944
- Days from application to issue
- 844
- Expires
- Jul 3, 2025
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit Renovation (Non-Structural) Permit Issued
Equipment upgrades at an existing wireless telecom facility. per plans.
- Permit
- 22-23038-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $59,000
- Fees
- $415
- Contractor
- Mastec Network Solutions LLC
- Days from application to issue
- 29
- Expires
- Feb 28, 2023
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Electrical Service / Circuit / Feeder Other
Install 60AMP disconnect on Verizon Small Cell Pole
- Permit
- 22-20944-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $67
- Contractor
- Brandon Michael Descant
- Application submitted
- Application review
Placed here by its map location from “1030 Howard Ave”.
-
Permit Electrical Service / Circuit / Feeder Permit Issued
Install 60 amp disconnect on Verizon small cell pole
- Permit
- 22-17546-SERV
- Type
- Electrical Service / Circuit / Feeder
- Work
- Electrical Service / Circuit / Feeder
- Estimated cost (applicant’s figure)
- $2,500
- Fees
- $82
- Contractor
- Timothy Jason Carman
- Days from application to issue
- 10
- Expires
- Dec 23, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
Placed here by its map location from “1030 Howard Ave, NA”.
-
Permit Renovation (Non-Structural) Permit Cancelled
Equipment upgrades at an existing wireless telecom facility. per plans.
- Permit
- 22-09665-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $59,000
- Fees
- $355
- Application submitted
- Zoning review
-
Permit Dumpster/Construction Zone Other
165(T) CRANE PLACEMENT TO LIFT/REMOVE EQUIPMENT TO THE ROOF TOP OF THE ARCHDIOCESE OF NEW ORLEANS.
- Permit
- 21-04871-RCZD
- Type
- Dumpster/Construction Zone
- Work
- Dumpster/Construction Zone
- Estimated cost (applicant’s figure)
- $0
- Fees
- $375
- Days from application to issue
- 1
- Expires
- Aug 23, 2021
-
Permit Small Cell Installation Other
Verizon is proposing to install a new network NODE support pole with small cell antenna in the public ROW. The pole will be painted green to match the surrounding structures.
- Permit
- 21-00352-SMCL
- Type
- Small Cell Installation
- Work
- Small Cell Installation
- Estimated cost (applicant’s figure)
- $0
- Fees
- $1,000
- Days from application to issue
- 288
- Expires
- Apr 22, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
Placed here by its map location from “1030 Howard Ave”.
-
Permit Accessory Structure Other
Removing 6 antennas & 9 RRUs (radios) and replacing them with 6 antennas and 9 RRUs. There will be no ground, electrical or structural work done. PERMIT EXTENDED TO 7/28/21
- Permit
- 20-32572-ACCS
- Type
- Accessory Structure
- Work
- Accessory Structure
- Estimated cost (applicant’s figure)
- $82,000
- Fees
- $617
- Contractor
- Mastec Network Solution
- Days from application to issue
- 217
- Expires
- Jul 28, 2021
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit Brake Tag Order Permit Issued
- Permit
- 19-25014-BTO
- Type
- Brake Tag Order
- Estimated cost (applicant’s figure)
- $0
- Fees
- $60
- Days from application to issue
- 5
-
Permit Street Cut Other
- Permit
- 19-10578-RSTC
- Type
- Street Cut
- Work
- Street Cut
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 22
- Expires
- Oct 25, 2019
-
Permit Brake Tag Order Permit Issued
- Permit
- 19-08356-BTO
- Type
- Brake Tag Order
- Estimated cost (applicant’s figure)
- $0
- Fees
- $20
- Days from application to issue
- 2
-
Permit Renovation (Non-Structural) Other
AT&T will be replacing 3 Antennas and 3 Radios and their associated equipment. They will also be adding 9 Radios and their associated equipment.
- Permit
- 18-11403-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $25,000
- Fees
- $185
- Contractor
- MasTec Network Solutions
- Days from application to issue
- 6
- Expires
- Oct 11, 2018
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
-
Permit RTA Shelter Permit Issued
Loyola & Howard (in)
- Permit
- 16-30780-RTA
- Type
- RTA Shelter
- Work
- RTA Shelter
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 971
- Expires
- Nov 16, 2019
-
Permit Renovation (Non-Structural) Other
Install 3 additional antennas to the existing rooftop equipment.
- Permit
- 15-25154-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $220
- Contractor
- Dynamic Tower Services, Mansour Shirvani
- Days from application to issue
- 32
- Expires
- Mar 21, 2016
-
Permit Attached Sign Permit Issued
Install 3 illuminated signs: (1) accessory flat LED message center (20'4"x8'4") on the Calliope St side of the structure, and 2 rooftop signs on existing sign superstructure (non-conforming) (48'10"x14' each).
- Permit
- 14-39728-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $1,550
- Days from application to issue
- 106
- Expires
- Oct 13, 2015
-
Permit Electrical Semi-Annual Maintenance Permit Issued
SEMI-ANNUAL INSPECTION
- Permit
- 13-08935-EANN
- Type
- Electrical Semi-Annual Maintenance
- Work
- Electrical Semi-Annual Maintenance
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Stephen Michael Guillot
- Days from application to issue
- 0
- Expires
- Sep 22, 2013
-
Permit Renovation (Non-Structural) Permit Issued
Remove/replace existing modified bitumen roof and install a siplast roof as per contract description.
- Permit
- 12-33554-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $37,875
- Fees
- $250
- Contractor
- Fischer's Inc
- Days from application to issue
- 0
- Expires
- Jun 17, 2013
-
Permit Renovation (Structural) Permit Issuance - Active
CO-LOCATE ANTENNAS ON EXISTING CELLULAR TOWER.
- Permit
- 11COM-00628
- Type
- Renovation (Structural)
- Work
- NA
- Estimated cost (applicant’s figure)
- $7,000
- Fees
- $95
- Days from application to issue
- 0
-
Code enforcement Case ENVHADJ-2006277F Closed
The property was inspected on 10/05/2006 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
The city links this case to permit 26-22250-SATT.
-
Permit Moving Equipment Application Acceptance - Approved
water damage ck# 2388617
- Permit
- 07MCH-12696
- Type
- Moving Equipment
- Work
- Elevators-Moving Equipment
- Estimated cost (applicant’s figure)
- $30,102
- Fees
- $350
- Contractor
- Schindler Elev.Corp.
- Days from application to issue
- 5
-
Permit Mechanical Online Pending
replace AHU & Ductwork in basement that was damaged by flooding
- Permit
- 06MCH-01135
- Type
- Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $250
- Fees
- $0
-
Permit General Mechanical Inspection - Completed
replace AHU and Ductwork in basement that was damaged by flood
- Permit
- 06MCH-01137
- Type
- General Mechanical
- Work
- General Mechanical
- Estimated cost (applicant’s figure)
- $250
- Fees
- $0
- Contractor
- Gallo Mech Contr
- Days from application to issue
- 13
-
Permit Electrical Repair / Replacement / Addition Permit Issuance - Active
Repair electrical systems damaged during Hurricane Katrina
- Permit
- 06ELC-04261
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $10,000
- Fees
- $0
- Days from application to issue
- 7
-
Permit Electrical Repair / Replacement / Addition Inspection - Completed
reconnect
- Permit
- 06ELC-07809
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Walter J Barnes Elec
- Days from application to issue
- 10
-
Permit Electrical Repair / Replacement / Addition Inspection - Completed
RECONNECT
- Permit
- 06ELC-05769
- Type
- Electrical Repair / Replacement / Addition
- Work
- Repair-Replacement-Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Walter J. Barnes Electrical
- Days from application to issue
- 10
-
Permit Emergency Permit Inspection - Completed
RELOCATE ELECTRICAL SWITCHGEAR, DOMESTIC WATER PUMPS, AND FIRE PUMP DUE TO HURRICANE KATRINA AS PER PLANS.
- Permit
- 05COM-01443
- Type
- Emergency Permit
- Work
- NA
- Estimated cost (applicant’s figure)
- $750,000
- Fees
- $4,550
- Days from application to issue
- 15
-
Permit Moving Equipment Certificate Of Completion - Issued No Meter
hurricane damage
- Permit
- 05MCH-07138
- Type
- Moving Equipment
- Work
- Elevators-Moving Equipment
- Estimated cost (applicant’s figure)
- $91,095
- Fees
- $960
- Contractor
- Schindler Elev.Corp.
- Days from application to issue
- 5
-
Permit Construction Loop Inspection - Completed
construction loop
- Permit
- 05ELC-11496
- Type
- Construction Loop
- Work
- Construction Loop
- Estimated cost (applicant’s figure)
- $0
- Fees
- $30
- Contractor
- Walter J Barnes Elec
- Days from application to issue
- 10
-
Permit New Construction Permit Issuance - Active
REPLACING CURRENT CELLULAR ANTENNAS WITH NEW CELLULAR ANTENNAS AND A SMALL EQUIPMENT CABINET AS PER PLANS.
- Permit
- 05COM-00020
- Type
- New Construction
- Work
- NA
- Estimated cost (applicant’s figure)
- $25,000
- Fees
- $225
- Contractor
- Tower Engineering, Inc.
- Days from application to issue
- 78
-
Permit Mechanical Annual Renewal Active
ANNUAL INSURANCE INSPECTION
- Permit
- 05MCH-00842
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $365
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-03051
- Type
- Mechanical
- Work
- Moving Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $105
-
Permit Mechanical
INSTALL MECHANICAL EQUIPMENT OFFICE BUILDING MODERNIZATION OF 3-ELEVATORS SCHINDLER - 734-0888
- Permit
- M03001181
- Type
- Mechanical
- Days from application to issue
- 1
-
Permit Building
ALTERATION ANTENNA INSTALL NEW EQUIPMENT PLATFORM & NEW GSM RADIO EQUIPMENT ON ROOFTOP OF EXISTING OFFICE BUILDING AS PER SKETCH.
- Permit
- B02004936
- Type
- Building
- Days from application to issue
- 0
Placed here by the building address from “1000 HOWARD AV UNIT ROOF”.