Behrman
3200 General De Gaulle Drive is in Behrman, zoned C-2 (Auto-oriented commercial for large stores and strip centers along major roads). The city has 19 permits on record here; the most recent, a renovation (structural) permit, was filed in November 2025. 10 are still open. There was 1 past code enforcement case, the latest in April 2009, all closed. On this block in the past year: 0 requests to 311 and 94 calls to police.
- Zoning
- C-2
- Historic district
- None
- Council district
- C
- Ward
- 15
- Lot size
- 169,085 sq ft
- Parcel
- 41182602
Everything on record here
20 records, newest first · 10 open
-
Permit Renovation (Structural) Permit Cancelled
The scope of work includes the demolition and reconstruction of fire damaged portion of the one-story pre-engineered metal storage building as indicated on the drawings, including: a. Remove and replacement of prefinished metal roof and wall panels. b. Replacement of cold formed steel roof purlins, channel columns and miscellaneous framing channels. c. Hollow metal frames and doors, including storage locker coiling overhead doors and corrugated metal swing doors. d. Replacement of vinyl faced batt insulation at underside of roof system. e. Replacement of electrical distribution panels, conduits, conductors, lighting, power and special systems. f. Replacement of mechanical split systems and ductwork.
- Permit
- 23-27953-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $919,590
- Fees
- $5,580
- Contractor
- Mapp Maintenance, LLC
- Expires
- Jul 17, 2025
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit Mechanical HVAC Other
Installing (3) 5 Ton electric heating and cooling systems in existing building
- Permit
- 25-12684-HVAC
- Type
- Mechanical HVAC
- Work
- Mechanical HVAC
- Estimated cost (applicant’s figure)
- $78,500
- Fees
- $153
- Contractor
- Mapp Maintenance, LLC
- Days from application to issue
- 3
- Expires
- Oct 28, 2025
- Application submitted
- Application review
- Permit approved
- First inspection
- Issue date
-
Permit Electrical Repair / Replacement / Addition Other
Demo electrical work damaged by fire, replace fixtures, repair feeder to damaged panel, replace damaged 225A panel, replace fire alarm devices damaged
- Permit
- 25-08705-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $57,275
- Fees
- $108
- Contractor
- Patrick Ruben Russo
- Days from application to issue
- 14
- Expires
- Oct 2, 2025
- Application submitted
- Application review
- Permit approved
- Issue date
- First inspection
-
Permit Interior Demolition Other
Interior Demo for fire damaged property. See permit # 23-27953-RNVS (Extra Space Storage, Inc.) NO USE OR OCCUPANCY. RENOVATION REQUIRES A SEPARATE PERMIT. Failure to secure the proper permits or proceed with work outside the scope of this permit will subject the property to additional fes, fines, adjudication and penalties. Call for inspections at or email to request a final inspection with the permit number.
- Permit
- 24-35306-DEMI
- Type
- Interior Demolition
- Work
- Interior Demolition
- Estimated cost (applicant’s figure)
- $39,500
- Fees
- $320
- Contractor
- Concrete Busters Of Louisiana
- Days from application to issue
- 6
- Expires
- May 26, 2025
- Application submitted
- Application review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit Renovation (Non-Structural) Other
Roof Coating Application: • Clean the roof surface using 299SRW Roof Wash and a minimum of 3000 psi pressure washer. Follow the directions for the 299SRW Roof Wash closely. • Apply AguaSeal Panel Seal Primer to all rusted areas at a minimum coverage rate of 200 ft2 per gallon. • Apply 1009SS Silicone Sealant to all curbs and penetrations. An application rate of 22-24 wet mils is recommended. • Apply 1009SS Silicone Sealant to all horizontal seams. An application rate of 22-24 wet mils is recommended. • Apply 1009SS Silicone Sealant to all vertical seams (Excluding Commercial Standing Seams). An application rate of 22-24 wet mils is recommended. • Apply 1009SS Silicone Sealant to all exposed fasteners. • High Movement Areas- If necessary, in areas of high movement install the applicable sized AguaSeal fabric embedded in the 792HS Silicone extending a minimum of 3 inches on each side of the seam. • Apply 1-2 costs of 792HS High Solids Silicone to the entire roof surface. • 10-Year Warranty- Apply a single coat at 1.5 gallons a square. (22-24 wet mils, 20-22 dry mils)
- Permit
- 24-35169-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $64,385
- Fees
- $450
- Contractor
- Platinum Roofing LLC
- Application submitted
- Zoning review
-
Permit Attached Sign Other
Change four faces on two signs. (1) monument sign and (1) building sign.
- Permit
- 24-32285-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $0
- Fees
- $310
- Contractor
- Alternative Signs & Graphics LLC
- Days from application to issue
- 20
- Expires
- May 11, 2025
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit Electrical Repair / Replacement / Addition Permit Cancelled
EMERGENCY RECONNECT
- Permit
- 22-05003-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $1,000
- Fees
- $40
- Contractor
- Stephen T Frischhertz
- Application submitted
-
Permit Electrical Repair / Replacement / Addition Permit Issued
EMERGENCY RECONNECT
- Permit
- 22-08734-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $1,000
- Fees
- $40
- Contractor
- Jonathan S. Frischhertz
- Days from application to issue
- 1
- Expires
- Sep 24, 2022
- Application submitted
- Application review
- Permit approved
- Issue date
-
Permit Renovation (Non-Structural) Permit Issued
Fire exploded on building 300 in a storage unit. There is currently an electrical permit pending to re-power all other buildings isolating power to the building that caught fire.
- Permit
- 22-05184-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $20,000
- Fees
- $160
- Contractor
- Mapp LLC
- Days from application to issue
- 34
- Expires
- Sep 23, 2022
- Application submitted
- Zoning review
- Application review
- Plan review
- Permit approved
- Issue date
-
Permit Electrical Repair / Replacement / Addition Permit Issued
- Permit
- 14-37919-ERPR
- Type
- Electrical Repair / Replacement / Addition
- Work
- Electrical Repair / Replacement / Addition
- Estimated cost (applicant’s figure)
- $0
- Fees
- $43
- Contractor
- THOMAS A. MICHEL
- Days from application to issue
- 0
- Expires
- Jun 8, 2015
-
Permit Construction Trailer Permit Issued
Job trailer 8'x20' to relocate office staff while existing office is being enlarged. (14-37051-RNVS)/Uncle Bob's parking lot.
- Permit
- 14-37595-TRLR
- Type
- Construction Trailer
- Work
- Construction Trailer
- Estimated cost (applicant’s figure)
- $0
- Fees
- $190
- Days from application to issue
- 0
- Expires
- Jun 4, 2015
-
Permit Renovation (Structural) Permit Finaled
Enlarging existing office space: Flooring,non-load bearing walls /adding new ones,sheetrock,painting;cabinets and trim.
- Permit
- 14-37051-RNVS
- Type
- Renovation (Structural)
- Work
- Renovation (Structural)
- Estimated cost (applicant’s figure)
- $19,000
- Fees
- $155
- Contractor
- James French
- Days from application to issue
- 0
- Expires
- Jun 1, 2015
-
Permit Electrical Vacancy Permit Issued
VACANCY
- Permit
- 13-30212-EVAC
- Type
- Electrical Vacancy
- Work
- Electrical Vacancy
- Estimated cost (applicant’s figure)
- $0
- Fees
- $40
- Contractor
- Hung The Nguyen
- Days from application to issue
- 0
- Expires
- Jan 11, 2014
Placed here by its tax bill number from “3642 General De Gaulle Dr [Mcdonalds]”.
-
Permit Renovation (Non-Structural) In Review
REMOVE/REPLACE ROOFING ON THE MANAGEMENT OFFICE OF UNCLE BOB'S STORAGE.
- Permit
- 12-27655-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $6,000
- Fees
- $90
- Contractor
- PORET CONSTRUCTION
- Days from application to issue
- 0
- Expires
- Apr 18, 2013
-
Permit Attached Sign In Review
REMOVE/INSTALL MONUMENT SIGN ON EXISTING FOUNDATION AS PER SKETCH AND CITY PLANNING APPROVAL.
- Permit
- 12-27330-SATT
- Type
- Attached Sign
- Work
- Attached Sign
- Estimated cost (applicant’s figure)
- $7,200
- Fees
- $455
- Contractor
- Arms Inc
- Days from application to issue
- 31
- Expires
- May 16, 2013
-
Code enforcement Case ENVHADJ-20015811P Closed
The property was inspected on 08/09/2001 with a finding of "Complete". The file was subsequently closed.
- Inspection: Inspection Complete
-
Permit Sign
DETACHED SIGN STORAGE BUILDING (MINI-WAREHOUSE) SIGN FEE 2004
- Permit
- S04000813
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
DETACHED SIGN STORAGE BUILDING (MINI-WAREHOUSE) SIGN FEE 2003 PAID FOR 1
- Permit
- S03000725
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
DETACHED SIGN STORAGE BUILDING (MINI-WAREHOUSE) SIGN FEE 2003
- Permit
- S03000163
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
DETACHED SIGN STORAGE BUILDING (MINI-WAREHOUSE) SIGN FEE
- Permit
- S02000487
- Type
- Sign
- Days from application to issue
- 0