Bywater

609 Congress Street is in Bywater, zoned HMR-3 (Marigny, Tremé and Bywater single- and two-family homes, with some small multi-family buildings). It is in the Bywater historic district under full HDLC control, so most exterior changes need approval first. The city has 16 permits on record here; the most recent, an HDLC COA permit, was filed in April 2026. 5 are still open. There is 1 open code enforcement case. On this block in the past year: 7 requests to 311 and 12 calls to police.

Zoning
HMR-3
Historic district
Bywater (Full control)
National Register
Bywater Historic District
Council district
C
Ward
9
Lot size
3,043 sq ft
Parcel
41206761

Everything on record here

17 records, newest first · 6 open

  1. Permit HDLC COA Permit Cancelled

    Old roof and underlayment and fasteners to be removed, 1/2" plywood sheathing fastened and new synthetic felt underlayment with slate color architectural shingle replacement

    Permit
    26-09702-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  2. Permit HDLC COA Permit Issued

    Replace roof

    Permit
    26-09946-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Oct 2, 2026

    See this permit on One Stop

  3. Permit Residential Re-Roofing Permit Cancelled

    Old roof and underlayment and fasteners to be removed, 1/2" plywood sheathing fastened and new synthetic felt underlayment with slate color architectural shingle replacement PLEASE NOTE: Re-roofing permits DO NOT require an inspection from Safety and Permits, instead please upload the following photos to this permit PHOTOS REQUIRED 4 geotagged photos (one from each side) showing: • Removal of existing roof material • Installation of water intrusion resistant underlayment • Installation of the drip-edge and flashing • Installation of shingles or metal panels  Once all applicable photos have been uploaded to the permit by the applicant, they must email <> requesting permit closure. http://onestopapp.nola.gov/

    Permit
    26-09702-ROOF
    Type
    Residential Re-Roofing
    Work
    Residential Re-Roofing
    Estimated cost (applicant’s figure)
    $0
    Fees
    $60
    Contractor
    Restorical Homes and Renovations LLC
    1. Application submitted
    2. Application review

    See this permit on One Stop

    Placed here by an address range from “609-611 Congress St”.

  4. Permit Residential Re-Roofing Permit Issued

    Remove old roofing and underlayment, fasten 1/2" sheathing to existing roof purlins with 3" nails at rafters and 2 3/8" on original heartpine purlins. Install flashing, Lay down synthetic undercoat, shingles, ridge caps.

    Permit
    26-09946-ROOF
    Type
    Residential Re-Roofing
    Work
    Residential Re-Roofing
    Estimated cost (applicant’s figure)
    $0
    Fees
    $90
    Contractor
    Restorical Homes and Renovations LLC
    Days from application to issue
    5
    Expires
    Oct 6, 2026
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

  5. Permit HDLC COA Permit Issued

    Renovate 611 side of 609-611 Congress St. 70117. Original vintage home exterior will not be altered in any way other than restoration of any damaged weatherboard and windows (half already restored in functioning order which have new sash cord and bronze weather stripping, tight seals to sills). Rear structure to be improved to a single "lean-to", all within or above IRC requirements, using 2x8 rafters with a 2x12 double header and 4 support 4x6's or 6x6 posts at midpoint from back of house to wall. Dimensions match width of house and 24' long (as original lean-to). Exterior to match existing 7" siding with Cypress or cement board, windows to be restored double hung sash to match existing either new or approved HDLC windows. Addition to be built on piers to match existing with treated 6x6's, and roof to be 2x8" rafters, 2x12 sistered midway from rear of house to back wall of restored structure, 4x6 or 6x6, posts to support (4).

    Permit
    25-27005-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    206
    Expires
    Oct 2, 2026

    See this permit on One Stop

    Placed here by an address range from “611 Congress St, 609 Congress St”.

  6. Permit Renovation (Structural) Other

    Renovate 611 side of 609-611 Congress St. 70117. Original vintage home exterior will not be altered in any way other than restoration of any damaged weatherboard and windows (half already restored in functioning order which have new sash cord and bronze weather stripping, tight seals to sills). Rear structure to be improved to a single "lean-to", all within or above IRC requirements, using 2x8 rafters with a 2x12 double header and 4 support 4x6's or 6x6 posts at midpoint from back of house to wall. Dimensions match width of house and 24' long (as original lean-to). Exterior to match existing 7" siding with Cypress or cement board, windows to be restored double hung sash to match existing either new or approved HDLC windows. Addition to be built on piers to match existing with treated 6x6's, and roof to be 2x8" rafters, 2x12 sistered midway from rear of house to back wall of restored structure, 4x6 or 6x6, posts to support (4).

    Permit
    25-27005-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $30,000
    Fees
    $405
    Contractor
    Jon Anderson
    1. Application submitted

    See this permit on One Stop

    Placed here by an address range from “611 Congress St, 609 Congress St”.

  7. Permit HDLC COA Permit Cancelled

    1.- Continue with re-painting house started last over 2 years ago, recently learned a permit was needed for undertaking of project by homeowner. Front of house to be painted as well, wall kept wet with water pump sprayer, and all scrapings captured by underlayment and properly disposed of in contractor bags, taken to landfill. Any weatherboards in poor condition to be replaced with matching 7" square edge #1 Cypress, all to be back-primed twice before installation. 2 windows left to scrape, fully removed from opening, all wood scraped, primed, painted and windows rehung with new sash cord weights and bronze weather stripping in rail channels on opening. 2.-- Roof- roof to be replaced with HDLC compliant architectural shingles. 3.- 1/2 round 6" gutters to be installed after roof completed, 3 downspouts per side

    Permit
    25-08802-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  8. Permit Renovation (Non-Structural) Permit Cancelled

    1.- Continue with re-painting house started last over 2 years ago, recently learned a permit was needed for undertaking of project by homeowner. Front of house to be painted as well, wall kept wet with water pump sprayer, and all scrapings captured by underlayment and properly disposed of in contractor bags, taken to landfill. Any weatherboards in poor condition to be replaced with matching 7" square edge #1 Cypress, all to be back-primed twice before installation. 2 windows left to scrape, fully removed from opening, all wood scraped, primed, painted and windows rehung with new sash cord weights and bronze weather stripping in rail channels on opening. 2.-- Roof- roof to be replaced with HDLC compliant architectural shingles. 3.- 1/2 round 6" gutters to be installed after roof completed, 3 downspouts per side

    Permit
    25-08802-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $19,000
    Fees
    $323
    1. Application submitted

    See this permit on One Stop

  9. Code enforcement Case 24-01467-MPM Judgment

    A hearing was held on 06/09/2025 with a result of "Guilty".

    1. Inspection
    2. Title Research
    3. Hearing
    4. Judgment
    5. In Compliance
    1. Inspection: Inspection Violation: No WIP
    2. Violation: 157 Sanitation
    3. Violation: 161 Rodent Harborage
    4. Violation: 167 Paint or Protective Treatment
    5. Violation: 169 Studs
    6. Violation: 171 Exterior Walls
    7. Violation: 171 Weatherboards
    8. Violation: 172 Gutters and Downspouts
    9. Violation: 172 Roofs
    10. Violation: 179 Windows
    11. Inspection: Posting of Hearing Notice Violation: No WIP
    12. Hearing: Initial Hearing Guilty
    13. Inspection: Posting of Notice of Daily Fines Hearing Complete
    14. Hearing: Reset Hearing Reset: Not Re-Inspected
    15. Inspection: Reinspection Violation: WIP
    16. Inspection: Posting of Notice of Daily Fines Hearing Violation: WIP
    17. Hearing: Reset Hearing Guilty

    The city links this case to permit 26-09702-ROOF.

  10. Permit HDLC COA Permit Cancelled

    Repairs water damaged bathrooms/kitchen/laundry room wall on the rear of a shotgun house. Replacing weatherboards/w cypress and updating electrical panels as per HDLC Approval. CLONE OF 15-34374-HDLC

    Permit
    17-17995-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Nov 22, 2017

    See this permit on One Stop

    Placed here by an address range from “609 Congress St, 611 Congress St”.

  11. Permit Electrical Service / Circuit / Feeder Permit Issued

    Rewire 15-34374

    Permit
    16-13950-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $103
    Contractor
    Charles Thurber Pierson
    Days from application to issue
    0
    Expires
    Oct 28, 2016

    See this permit on One Stop

  12. Permit Electrical Service / Circuit / Feeder Permit Issued

    Rewire 15-34374

    Permit
    16-13610-SERV
    Type
    Electrical Service / Circuit / Feeder
    Work
    Electrical Service / Circuit / Feeder
    Estimated cost (applicant’s figure)
    $0
    Fees
    $106
    Contractor
    Charles Thurber Pierson
    Days from application to issue
    0
    Expires
    Oct 26, 2016

    See this permit on One Stop

  13. Permit Renovation (Structural) Permit Issued

    Repairs water damaged bathrooms/kitchen/laundry room wall on the rear of a shotgun house. Replacing weatherboards/w cypress and updating electrical panels as per HDLC Approval. 609-611 Congress. Permits extended for 6 months until 5/21/2017 Permit extended for 6 months until 11/22/2017

    Permit
    15-34374-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $5,000
    Fees
    $258
    Days from application to issue
    10
    Expires
    May 23, 2016

    See this permit on One Stop

    Placed here by an address range from “609/11 Congress St”.

  14. Permit HDLC COA Permit Cancelled

    Repairs water damaged bathrooms/kitchen/laundry room wall on the rear of a shotgun house. Replacing weatherboards/w cypress and updating electrical panels as per HDLC Approval. Re-issued as 17-17995-HDLC

    Permit
    15-34374-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    10
    Expires
    May 23, 2016

    See this permit on One Stop

    Placed here by an address range from “609 Congress St, 611 Congress St”.

  15. Permit Repair In Review

    Replace some rotten wood around windows on back half of existing double as per HDLC C/A #

    Permit
    12-34698-REPR
    Type
    Repair
    Work
    Repair
    Estimated cost (applicant’s figure)
    $1,000
    Fees
    $98

    See this permit on One Stop

  16. Permit HDLC COA Permit Cancelled
    Permit
    12-34703-HDLC
    Type
    HDLC COA
    Work
    HDLC COA
    Estimated cost (applicant’s figure)
    $0
    Fees
    $50
    Days from application to issue
    77
    Expires
    Sep 15, 2013

    See this permit on One Stop

  17. Permit Mechanical

    INSTALL MECHANICAL EQUIPMENT DOUBLE RESIDENCE INSTALL GAS LINE WHITE STAR\ LWEIS 416-7941

    Permit
    M01006417
    Type
    Mechanical
    Days from application to issue
    3