French Quarter

1015 Governor Nicholls Street is in French Quarter, zoned VCR-1 (French Quarter residential, preserving the area's character). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 13 permits on record here; the most recent, a VCC general work permit, was filed in December 2025. 9 are still open. There was 1 past code enforcement case, the latest in April 2009, all closed. On this block in the past year: 4 requests to 311 and 18 calls to police.

Zoning
VCR-1
Historic district
Vieux Carré (Full control)
National Register
Vieux Carre
Council district
C
Ward
6
Lot size
4,767 sq ft
Parcel
41218980

Everything on record here

14 records, newest first · 9 open

  1. Permit VCC General Work Permit Issued

    Permit to perform below-grade exploratory demolition at interior side of masonry piers beneath Gov. Nicholls-side porch to determine the scope of future structural work. See attached materials stamped VCC approved 12/11/2025. NOTE: A professional engineer should be engaged to shore and secure the porch structure to stabilize it and prevent additional masonry failure or further structural issues temporarily. Once the extant conditions are fully understood, the conditions should be thoroughly documented in photographs and engineering drawings of the remediation work should be drafted and presented to DSP and VCC for review and approval so that repair permits can be issued. No work shall take place that involves or damages the rusticated finish blocks on the Gov. Nicholls-side face of the load-bearing wall, as this material is no longer readily available and would be very difficult to source and replace.

    Permit
    25-32468-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    0
    Expires
    Jun 11, 2026

    See this permit on One Stop

  2. Permit Renovation (Structural) Permit Issued

    Exploratory demolition of the front porch load bearing brick wall and foundation below grade plus analysis of any additional structural concerns. .After pursuing a permit through the VCC to re-point and shore up our front porch load-bearing brick wall (reference code C31KHZ), the Architecture Committee ruled that we should get a general permit to dig in just enough to get some engineering drawings. The contractor's engineer will submit these drawings to move the permit to the next stage of work. We will then take those drawings to the VCC and get approval for that permit. Per Bryan Block from VCC: "The engineer should then investigate causes of the apparent failure. This would likely include exploratory demolition of the foundation below grade and analysis of any additional structural concerns. Permits should be obtained from the Dept of Safety and Permits (DSP) for this and all work prior to commencing." We have been seeking permission to move forward since April.

    Permit
    25-32468-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $3,925
    Fees
    $140
    Contractor
    Silva Construction, LLC
    Days from application to issue
    117
    Expires
    Aug 10, 2026
    1. Application submitted
    2. Application review
    3. Zoning review
    4. Plan review
    5. Permit approved
    6. Issue date

    See this permit on One Stop

  3. Permit VCC General Work In Review

    Re-point brick piers under porch and level porch

    Permit
    25-11805-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  4. Permit Renovation (Structural) Application Accepted

    Re-point brick piers under porch, exploratory demolition of the foundation beow grade and analysis of any additional structural concerns, and level porch.

    Permit
    25-11805-RNVS
    Type
    Renovation (Structural)
    Work
    Renovation (Structural)
    Estimated cost (applicant’s figure)
    $3,500
    Fees
    $140
    1. Application submitted

    See this permit on One Stop

  5. Permit VCC Paint Permit Issued

    wood siding walls: Potentially purple, flat or eggshell shutters, foundation and stairs: rockwood green, semigloss all windows, doors, trim, columns and any wooden decorative elements: white, semigloss

    Permit
    24-07859-VCPNT
    Type
    VCC Paint
    Work
    VCC Paint
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    17
    Expires
    Oct 5, 2024

    See this permit on One Stop

  6. Permit VCC General Work Permit Issued

    **ALL NEW GUTTERS AND DOWNSPOUTS TO MATCH EXISTING IN SIZE, SHAPE, MATERIAL AND LOCAITON. remove and replace half round gutters on main buildign to match and painted white remove and replace downspouts where necessary to match existing

    Permit
    23-13728-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    1
    Expires
    Nov 23, 2023

    See this permit on One Stop

  7. Permit Renovation (Non-Structural) Permit Cancelled

    Half round gutters replacement

    Permit
    23-13728-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $10,200
    Fees
    $263
    1. Application submitted

    See this permit on One Stop

  8. Permit VCC General Work Permit Issued

    ALL WORK TO MATCH EXISITNG to replace/ repair 10 broken slate shingles

    Permit
    21-27471-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    2
    Expires
    Apr 8, 2022

    See this permit on One Stop

  9. Permit Renovation (Non-Structural) Permit Cancelled

    We are looking to repair ten (10) slate shingles. See attached.

    Permit
    21-27471-RNVN
    Type
    Renovation (Non-Structural)
    Work
    Renovation (Non-Structural)
    Estimated cost (applicant’s figure)
    $1,085
    Fees
    $105
    1. Application submitted

    See this permit on One Stop

  10. Permit VCC General Work Permit Cancelled

    We (General Heating and Air Conditioning 3500 Monticello St, New Orleans) are applying for a permit from the VCC to remove an existing air condition condenser and indoor air handler at the residence 1015 Governor Nichols St unit 1. We have a permit to proceed from the city. Permit number is 20-41614-HVAC Mechanical HVAC. There will be no changes to the exterior of the home with our project. The outdoor condenser is located under the home and can not be seen. We will be replacing the condenser with a similar size condenser under the home. The interior part is in the attic and can not be seen. Any questions call Bryan Hale

    Permit
    20-43154-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0

    See this permit on One Stop

  11. Permit Mechanical HVAC Permit Cancelled

    We (General Heating and Air Conditioning 3500 Monticello St, New Orleans) are applying for a permit from the VCC to remove an existing air condition condenser and indoor air handler at the residence 1015 Governor Nichols St unit 1. We have a permit to proceed from the city. Permit number is 20-41614-HVAC Mechanical HVAC. There will be no changes to the exterior of the home with our project. The outdoor condenser is located under the home and can not be seen. We will be replacing the condenser with a similar size condenser under the home. The interior part is in the attic and can not be seen. Any questions call Bryan Hale

    Permit
    20-43154-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $14,640
    Fees
    $45
    Contractor
    Aka General Heating/Ac
    1. Application submitted

    See this permit on One Stop

  12. Permit VCC General Work Other

    Remove existing 2.5 ton A/C system mounted beneath house in Burgundy-side alley. Install new Daikin DX17VSS301AA mini-split unit in same location, per attached materials stamped VCC approved 11/16/2020.

    Permit
    20-41614-VCGEN
    Type
    VCC General Work
    Work
    VCC General Work
    Estimated cost (applicant’s figure)
    $0
    Fees
    $0
    Days from application to issue
    45
    Expires
    May 16, 2021

    See this permit on One Stop

  13. Permit Mechanical HVAC Permit Issued

    Remove and replace existing 2.5 ton A/C system.

    Permit
    20-41614-HVAC
    Type
    Mechanical HVAC
    Work
    Mechanical HVAC
    Estimated cost (applicant’s figure)
    $14,640
    Fees
    $90
    Days from application to issue
    56
    Expires
    May 20, 2021
    1. Application submitted
    2. Application review
    3. Permit approved
    4. Issue date

    See this permit on One Stop

  14. Code enforcement Case ENVHADJ-20014262SN Closed

    A hearing was held on 04/10/2009 with a result of "Found Guilty". The case was subsequently closed.

    1. Inspection: Inspection Complete
    2. Hearing: Initial Hearing Found Guilty

    The city links this case to permit 25-32468-VCGEN.