French Quarter
538 Royal Street is in French Quarter, zoned VCC-2 (French Quarter shops and services, including the main shopping area). It is in the French Quarter, where the Vieux Carré Commission reviews exterior work before it starts. The city has 14 permits on record here; the most recent, a VCC general work permit, was filed in May 2021. 7 are still open. On this block in the past year: 9 requests to 311 and 58 calls to police.
- Zoning
- VCC-2
- Historic district
- Vieux Carré (Full control)
- National Register
- Vieux Carre
- Council district
- C
- Ward
- 5
- Lot size
- 2,424 sq ft
- Parcel
- 41223339
Everything on record here
14 records, newest first · 7 open
-
Permit VCC General Work Permit Finaled
• Remove existing fiber cement synthetic roofing material • Repair and/or replace underlayment as necessary • Install new natural slate (grey/green), using copper nails • Install/repair half round copper gutters and flashing • Install/reinstall ceramic or concrete V-style or terra cotta ridge tiles. Replace broken tiles as needed, to match existing. • Metal cap-flashing on the parapets or chimneys is not allowed. Remove existing chimney caps and install new caps per attached typical detail sheet. Note: Trash chutes are required for removal of debris from all roofs All work must conform to standard VCC policies & guidelines Permit does not allow for cap flashing on parapets, chimneys or surrounding walls Torch-applied roofing is not permitted in the Vieux Carré.
- Permit
- 21-15057-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 158
- Expires
- May 1, 2022
-
Permit Renovation (Non-Structural) Occupancy
Roofing Permit: Remove Hardi Tiles on rear slope; apply plywood decking if needed; install underlayment, copper flashings, 12 x 18 gray/green Vermont genuine slates, reinstall terra cotta ridge tiles. Replace damaged Eternit tiles on roof with custom fabricated tiles in some color and configuration.
- Permit
- 21-15057-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $26,850
- Fees
- $293
- Contractor
- Robertson Roofing
- Days from application to issue
- 875
- Expires
- Apr 16, 2024
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit VCC General Work Permit Finaled
Remove deteriorated floor boards, stringers, and fascia boards. Install new 3"x4" beaded stringers, 5/4x4 wood T&G floorboards, and 7/8" fascia with ½" bead, all as per VCC Standard Detail Sheet No. 12 (attached). Repair shutters to match existing, as needed. Remove vegetation from masonry. Cut vegetation down and apply “RoundUp” or equal. Remove dead roots after 1-2 days. Install new VCC mortar (formula attached) and/or VCC stucco (formula attached) as needed where deteriorated. Remove illegal chimney caps installed without benefit of VCC review or approval and replace with typical chimney cap (see detail attached) Remove abandoned wiring as needed. Install remaining wiring in conduits. All conduits shall be placed along the inside corners of building surfaces as much as possible, such as along gallery purlins at the deck line, and painted to match the adjacent surfaces. Retroactive approval to remove second floor awning on Royal elevation of rear, Toulouse-side dependency building. Remove all remaining wood and flashing from wall and repair mortar and stucco as needed using VCC mortar/stucco formula (attached). All repair/replacement work shall match existing in color, size, material, detail, profile and exposure NOTE: Permit issued in response to violations. Work shall commence no less than 30 days after permit is issued. Work must be completed no less than 60 days after work begins. Owner will call VCC for final inspection upon completion of work.
- Permit
- 19-01176-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
- Days from application to issue
- 25
- Expires
- Aug 8, 2019
-
Permit Renovation (Non-Structural) Occupancy
Addressing VCC Violations - scope of work to include repairing and replacing tongue and groove deck board, shutters, remove vegetation, remove chimney caps, scrape paint off wall, paint, install conduit. No structual work
- Permit
- 19-01176-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $14,750
- Fees
- $293
- Days from application to issue
- 33
- Expires
- Aug 13, 2019
- Application submitted
- Application review
- Zoning review
- Plan review
- Permit approved
- Issue date
- First inspection
-
Permit Renovation (Non-Structural) Permit Cancelled
Updating Existing Permit Request
- Permit
- 18-36832-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,400
- Fees
- $135
- Application submitted
-
Permit VCC General Work Permit Cancelled
repair deck boardss, facia and floor joists. paint to match existing repair shutters where necessary ➢ Clean plants (fern) off building ➢ Prep/paint 3 areas on exterior of building that are peeling with approved vcc mortar mix, matching paint (provided by owner half way up wall) ➢ Find all active electrical wires on the exterior of building and encase them in conduit ➢ Replace Flashing on back wall in carriage way with wood primed and painted to match existing finish ➢ Remove deteriorated structure from back balcony ➢ Cleaned up and hauled trash related to work completed above
- Permit
- 18-36017-VCGEN
- Type
- VCC General Work
- Work
- VCC General Work
- Estimated cost (applicant’s figure)
- $0
- Fees
- $0
-
Permit Renovation (Non-Structural) Permit Cancelled
➢ Balcony repair on left side of property to rotten Deck boards, facia and floor joists. ➢ Prime and paint areas worked on to match existing finish ➢ Will do all shutter repair with existing shutters that match and are present on the property ➢ Clean plants (fern) off building ➢ Prep/paint 3 areas on exterior of building that are peeling with approved vcc mortar mix, matching paint (provided by owner half way up wall) ➢ Find all active electrical wires on the exterior of building and encase them in conduit ➢ Replace Flashing on back wall in carriage way with wood primed and painted to match existing finish ➢ Remove deteriorated structure from back balcony ➢ Cleaned up and hauled trash related to work completed above
- Permit
- 18-36017-RNVN
- Type
- Renovation (Non-Structural)
- Work
- Renovation (Non-Structural)
- Estimated cost (applicant’s figure)
- $5,400
- Fees
- $225
- Application submitted
- Application review
-
Permit Mechanical Annual Fee Pending
- Permit
- 03MCH-06880
- Type
- Mechanical
- Work
- Stationary Equipment Annual
- Estimated cost (applicant’s figure)
- $0
- Fees
- $37
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2004
- Permit
- S04000907
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2003 PAID FOR 2 SIGNS
- Permit
- S03000379
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE
- Permit
- S02000341
- Type
- Sign
- Days from application to issue
- 0
-
Permit Sign
PROJECTING SIGN RETAIL STORE SIGN FEE 2001 PAID
- Permit
- S01000574
- Type
- Sign
- Days from application to issue
- 0
-
Permit Building
RE-ROOF (COMMERCIAL) ART (GALLERY) REMV/REPL 85SF HAIL DAMAGED ABESTOS SHINGLES & INSTALLING FIRE FREE SHINGLES AS PER VCC PERMIT #010314.
- Permit
- B01001732
- Type
- Building
- Days from application to issue
- 0
-
Permit Building
FRENCH QUARTER FEST NEUTRAL GROUND (MEDIAN) CERTIFICATE OF OCCUPANCY TO DISPLAY A BANNER BETWEEN 540 AND 600 ROYAL ST FROM APRIL 16-19, 1998 PER VCC#980183 AND ORD 18660 MCS.
- Permit
- B98001956
- Type
- Building